Simple proton spectroscopic imaging.
The DOI matches its Crossref record.
Abstract
Simple modification of a spin echo imaging pulse sequence generates useful spectroscopic information at 0.35 T. New images are produced that show water only, fat only, and the difference between water and fat intensity. Imaging speed, spatial resolution, and signal-to-noise ratio are comparable with ordinary imaging. The method provides new parameters for tissue characterization and improved contrast between some organs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Items 101–111 of 111
Characterisation of liver fat in the UK Biobank cohort
Wilman, H. R., Kelly, M., Garratt, S., Matthews, P. M., Milanesi, M., Herlihy, A., Gyngell, M., Neubauer, S., Bell, J. D., Banerjee, R., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172921 · Cited by 159
“Furthermore the PDFF measurements used in this study were derived from MRI images captured using the DIXON technique [20,21], however the IDEAL method [22] is now considered a more robust and accurate method for measuring liver PDFF, therefore the acquisition sequences used by the UKBiobank have been altered to reflec…”
MethodQuantification of Liver Fat Content with Ultrasound: A WFUMB Position Paper
Ferraioli, G., Berzigotti, A., Barr, R. G., Choi, B. I., Cui, X. W., Dong, Y., Gilja, O. H., Lee, J. Y., Lee, D. H., Moriyasu, F., et al. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.06.002 · Cited by 159
Feasibility of MR-Based Body Composition Analysis in Large Scale Population Studies
West, J., Dahlqvist Leinhard, O., Romu, T., Collins, R., Garratt, S., Bell, J. D., Borga, M., & Thomas, L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163332 · Cited by 158
Fischer, M. A., Pfirrmann, C. W. A., Espinosa, N., Raptis, D. A., & Buck, F. M. (2014) · European Radiology · doi:10.1007/s00330-014-3121-1 · Cited by 112
“This algorithm was shown to provide stable water- and fat-signal separation for dual-echo imaging using phase information to resolve the ambiguity of fat and water signal in chemical-shift imaging [3, 13].”
MethodMRI in the assessment of adipose tissues and muscle composition: how to use it
Huber, F. A., Del Grande, F., Rizzo, S., Guglielmi, G., & Guggenberger, R. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2020.02.06 · Cited by 102
Heusch, P., Buchbender, C., Beiderwellen, K., Nensa, F., Hartung-Knemeyer, V., Lauenstein, T. C., Bockisch, A., Forsting, M., Antoch, G., & Heusner, T. A. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.01.008 · Cited by 96
Costa, D. N., Pedrosa, I., McKenzie, C., Reeder, S. B., & Rofsky, N. M. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3182 · Cited by 87
Machann, J., Bachmann, O. P., Brechtel, K., Dahl, D. B., Wietek, B., Klumpp, B., Häring, H., Claussen, C. D., Jacob, S., & Schick, F. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10255 · Cited by 73
“Besides (1)H MRS, several magnetic resonance imaging (MRI) techniques, such as inversion recovery techniques (18–20), chemical shift selective imaging (21), phase-sensitive techniques (22,23), or spectral spatial excitation (24–29), allow a separate depiction of water or fat component in any site of the human body.”
BackgroundSmall animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Grimm, A., Nickel, M. D., Chaudry, O., Uder, M., Jakob, F., Kemmler, W., Quick, H. H., & Engelke, K. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.03.019 · Cited by 16
Zhao, J., Xue, Q., Chen, X., You, Z., Wang, Z., Yuan, J., Liu, H., & Hu, L. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00363-w · Cited by 12
Metadata
- Authors
- Dixon, W. T.
- Venue
- Radiology
- Published
- 1984-10
- Volume
- 153
- Issue
- 1
- Pages
- 189-194
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2066125032
- Cited by
- 2,276
- References
- 0
- FWCI
- 31.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.