Simple proton spectroscopic imaging.
The DOI matches its Crossref record.
Abstract
Simple modification of a spin echo imaging pulse sequence generates useful spectroscopic information at 0.35 T. New images are produced that show water only, fat only, and the difference between water and fat intensity. Imaging speed, spatial resolution, and signal-to-noise ratio are comparable with ordinary imaging. The method provides new parameters for tissue characterization and improved contrast between some organs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils
Gruetter, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290613 · Cited by 870
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
McRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Schwenzer, N. F., Springer, F., Schraml, C., Stefan, N., Machann, J., & Schick, F. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.05.023 · Cited by 749
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Studies of human tumors by MRS: A review
Negendank, W. (1992) · NMR in Biomedicine · doi:10.1002/nbm.1940050518 · Cited by 660
Evidence for two types of brown adipose tissue in humans
Lidell, M. E., Betz, M. J., Leinhard, O. D., Heglind, M., Elander, L., Slawik, M., Mussack, T., Nilsson, D., Romu, T., Nuutila, P., et al. (2013) · Nature Medicine · doi:10.1038/nm.3017 · Cited by 657
Stern, C. E., Corkin, S., González, R. G., Guimaraes, A. R., Baker, J. R., Jennings, P. J., Carr, C. A., Sugiura, R. M., Vedantham, V, & Rosen, B. R. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.16.8660 · Cited by 639
Dixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610
Advanced Body Composition Assessment: From Body Mass Index to Body Composition Profiling
Borga, M., West, J., Bell, J. D., Harvey, N. C., Romu, T., Heymsfield, S. B., & Dahlqvist Leinhard, O. (2018) · Journal of Investigative Medicine · doi:10.1136/jim-2018-000722 · Cited by 606
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
“Common MRI fat-suppression methods include spectrally-selective saturation [14], STIR [15], or multiple-echo separation techniques such as Dixon separation [16, 17].”
MethodMRI of the tumor microenvironment
Gillies, R. J., Raghunand, N., Karczmar, G. S., & Bhujwalla, Z. M. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10181 · Cited by 550
JAK1/2 inhibition with baricitinib in the treatment of autoinflammatory interferonopathies
Sanchez, G. A. M., Reinhardt, A., Ramsey, S., Wittkowski, H., Hashkes, P. J., Berkun, Y., Schalm, S., Murias, S., Dare, J. A., Brown, D., et al. (2018) · Journal of Clinical Investigation · doi:10.1172/jci98814 · Cited by 536
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Schwimmer, J. B., Dunn, W., Norman, G. J., Pardee, P. E., Middleton, M. S., Kerkar, N., & Sirlin, C. B. (2010) · Gastroenterology · doi:10.1053/j.gastro.2009.12.052 · Cited by 498
Fat Suppression in MR Imaging: Techniques and Pitfalls
Delfaut, E. M., Beltran, J., Johnson, G., Rousseau, J., Marchandise, X., & Cotten, A. (1999) · RadioGraphics · doi:10.1148/radiographics.19.2.g99mr03373 · Cited by 487
Breast Tissue Composition and Susceptibility to Breast Cancer
Boyd, N. F., Martin, L. J., Bronskill, M., Yaffe, M. J., Duric, N., & Minkin, S. (2010) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djq239 · Cited by 478
Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Heritability of Nonalcoholic Fatty Liver Disease
Schwimmer, J. B., Celedon, M. A., Lavine, J. E., Salem, R., Campbell, N., Schork, N. J., Shiehmorteza, M., Yokoo, T., Chavez, A., Middleton, M. S., et al. (2009) · Gastroenterology · doi:10.1053/j.gastro.2009.01.050 · Cited by 466
Multiecho reconstruction for simultaneous water‐fat decomposition and T2* estimation
Yu, H., McKenzie, C. A., Shimakawa, A., Vu, A. T., Brau, A. C. S., Beatty, P. J., Pineda, A. R., Brittain, J. H., & Reeder, S. B. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21090 · Cited by 437
Radiologic evaluation of nonalcoholic fatty liver disease
Lee, S. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i23.7392 · Cited by 426
Multipoint dixon technique for water and fat proton and susceptibility imaging
Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010504 · Cited by 405
Relaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394
Proton MR spectroscopy in quantitative in vivo determination of fat content in human liver steatosis
Longo, R., Pollesello, P., Ricci, C., Masutti, F., Kvam, B. J., Bercich, L., Croce, L. S., Grigolato, P., Paoletti, S., De Bernard, B., et al. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050311 · Cited by 387
Kuriyan, R. (2018) · Indian Journal of Medical Research · doi:10.4103/ijmr.ijmr_1777_18 · Cited by 384
MR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask
Bitar, R., Leung, G., Perng, R., Tadros, S., Moody, A. R., Sarrazin, J., McGregor, C., Christakis, M., Symons, S., Nelson, A., et al. (2006) · RadioGraphics · doi:10.1148/rg.262055063 · Cited by 383
Weisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381
A review of substitute CT generation for MRI-only radiation therapy
Edmund, J. M., & Nyholm, T. (2017) · Radiation Oncology · doi:10.1186/s13014-016-0747-y · Cited by 378
Fat and water magnetic resonance imaging
Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21895 · Cited by 372
Owen, A. M., Stern, C. E., Look, R. B., Tracey, I., Rosen, B. R., & Petrides, M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.13.7721 · Cited by 371
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
MR Imaging with Hyperpolarized 3He Gas
Middleton, H., Black, R. D., Saam, B., Cates, G. D., Cofer, G. P., Guenther, R., Happer, W., Hedlund, L. W., Alan Johnson, G., Juvan, K., et al. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330219 · Cited by 358
Water–fat separation with IDEAL gradient‐echo imaging
Reeder, S. B., McKenzie, C. A., Pineda, A. R., Yu, H., Shimakawa, A., Brau, A. C., Hargreaves, B. A., Gold, G. E., & Brittain, J. H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20831 · Cited by 357
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Berker, Y., Franke, J., Salomon, A., Palmowski, M., Donker, H. C. W., Temur, Y., Mottaghy, F. M., Kuhl, C., Izquierdo-Garcia, D., Fayad, Z. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092577 · Cited by 344
Quantification of Liver Fat with Magnetic Resonance Imaging
Reeder, S. B., & Sirlin, C. B. (2010) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2010.08.013 · Cited by 342
Diagnosis of fatty liver disease: is biopsy necessary?
Joy, D., Thava, V. R., & Scott, B. B. (2003) · European Journal of Gastroenterology & Hepatology · doi:10.1097/00042737-200305000-00014 · Cited by 341
Hernando, D., Kellman, P., Haldar, J. P., & Liang, Z. ‐. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22177 · Cited by 336
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Quantification of liver fat using magnetic resonance spectroscopy
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92543-7 · Cited by 332
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320
Imaging-based Quantification of Hepatic Fat: Methods and Clinical Applications
Ma, X., Holalkere, N.-S., R, A. K., Mino-Kenudson, M., Hahn, P. F., & Sahani, D. V. (2009) · RadioGraphics · doi:10.1148/rg.295085186 · Cited by 312
Yokoo, T., Bydder, M., Hamilton, G., Middleton, M. S., Gamst, A. C., Wolfson, T., Hassanein, T., Patton, H. M., Lavine, J. E., Schwimmer, J. B., et al. (2009) · Radiology · doi:10.1148/radiol.2511080666 · Cited by 303
Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 T
Yokoo, T., Shiehmorteza, M., Hamilton, G., Wolfson, T., Schroeder, M. E., Middleton, M. S., Bydder, M., Gamst, A. C., Kono, Y., Kuo, A., et al. (2011) · Radiology · doi:10.1148/radiol.10100659 · Cited by 290
Hofmann, M., Bezrukov, I., Mantlik, F., Aschoff, P., Steinke, F., Beyer, T., Pichler, B. J., & Schölkopf, B. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.078949 · Cited by 288
Hepatic MRI for Fat Quantitation: Its Relationship to Fat Morphology, Diagnosis, and Ultrasound
Fishbein, M., Castro, F., Cheruku, S., Jain, S., Webb, B., Gleason, T., & Stevens, W. R. (2005) · Journal of Clinical Gastroenterology · doi:10.1097/00004836-200508000-00012 · Cited by 277
Hepatic Fat Fraction: MR Imaging for Quantitative Measurement and Display—Early Experience
Hussain, H. K., Chenevert, T. L., Londy, F. J., Gulani, V., Swanson, S. D., McKenna, B. J., Appelman, H. D., Adusumilli, S., Greenson, J. K., & Conjeevaram, H. S. (2005) · Radiology · doi:10.1148/radiol.2373041639 · Cited by 277
Noninvasive evaluation of NAFLD
Castera, L., Vilgrain, V., & Angulo, P. (2013) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2013.175 · Cited by 273
Review of medical image quality assessment
Chow, L. S., & Paramesran, R. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.02.006 · Cited by 265
PET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging
Vandenberghe, S., & Marsden, P. K. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/4/r115 · Cited by 258
Crawford, R. J., Filli, L., Elliott, J. M., Nanz, D., Fischer, M. A., Marcon, M., & Ulbrich, E. J. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4596 · Cited by 257
Non-invasive means of measuring hepatic fat content
Mehta, S. R., Thomas, E. L., Bell, J. D., Johnston, D. G., & Taylor-Robinson, S. D. (2008) · World Journal of Gastroenterology · doi:10.3748/wjg.14.3476 · Cited by 255
Maspero, M., Savenije, M. H. F., Dinkla, A. M., Seevinck, P. R., Intven, M. P. W., Jurgenliemk-Schulz, I. M., Kerkmeijer, L. G. W., & van den Berg, C. A. T. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aada6d · Cited by 253
Kramer, H., Pickhardt, P. J., Kliewer, M. A., Hernando, D., Chen, G.-H., Zagzebski, J. A., & Reeder, S. B. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.16.16565 · Cited by 252
Ma, J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20146 · Cited by 249
Quantitative analysis of skeletal muscle by computed tomography imaging—State of the art
Engelke, K., Museyko, O., Wang, L., & Laredo, J.-D. (2018) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2018.10.004 · Cited by 248
“MR spectroscopy (MRS) and Dixon sequences [13,14] are MR techniques originally developed to quantify the fat content of the liver, which, from the perspective of MRI, is a very homogenous organ.”
BackgroundPolymorphism of the PEMT gene and susceptibility to nonalcoholic fatty liver disease (NAFLD)
Song, J., Da Costa, K. A., Fischer, L. M., Kohlmeier, M., Kwock, L., Wang, S., & Zeisel, S. H. (2005) · The FASEB Journal · doi:10.1096/fj.04-3580com · Cited by 239
Patton, H. M., Sirlin, C., Behling, C., Middleton, M., Schwimmer, J. B., & Lavine, J. E. (2006) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/01.mpg.0000239995.58388.56 · Cited by 237
Hsu, S.-H., Cao, Y., Huang, K., Feng, M., & Balter, J. M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8419 · Cited by 233
“T1-weighted, T2-weighted FLAIR, UTE with echoes at TE of 0.06 (UTE1) and 4.6 ms (UTE2) as well as calculated fat and water image volumes (from a 2-point Dixon technique (Dixon 1984)) are included in this example to differentiate the major tissue types of bone, fat, solid tissue, fluid and air.”
MethodInfluentialFlorkow, M. C., Willemsen, K., Mascarenhas, V. V., Oei, E. H. G., van Stralen, M., & Seevinck, P. R. (2022) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28067 · Cited by 232
“Alternatively, water-only images can be generated by acquiring a GRE sequence with specific echo times to perform a Dixon water–fat separation.(25,28,29,68,69)”
MethodYip, C., Dinkel, C., Mahajan, A., Siddique, M., Cook, G. J. R., & Goh, V. (2015) · Insights into Imaging · doi:10.1007/s13244-015-0414-0 · Cited by 230
Introduction of fast MR imaging in the assessment of hepatic steatosis
Fishbein, M. H., Gardner, K. G., Potter, C. J., Schmalbrock, P., & Smith, M. A. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00224-x · Cited by 226
Quantifying fat replacement of muscle by quantitative MRI in muscular dystrophy
Burakiewicz, J., Sinclair, C. D. J., Fischer, D., Walter, G. A., Kan, H. E., & Hollingsworth, K. G. (2017) · Journal of Neurology · doi:10.1007/s00415-017-8547-3 · Cited by 225
Hines, C. D. G., Yu, H., Shimakawa, A., McKenzie, C. A., Brittain, J. H., & Reeder, S. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21957 · Cited by 221
“Two-point Dixon fat-fraction images were postprocessed in Matlab (R2007b, Mathworks, Natick, MA) using the in-phase and out of phase images according to Dixon (20).”
MethodInfluentialField map estimation with a region growing scheme for iterative 3‐point water‐fat decomposition
Yu, H., Reeder, S. B., Shimakawa, A., Brittain, J. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20654 · Cited by 217
Liver fat quantification using a multi‐step adaptive fitting approach with multi‐echo GRE imaging
Zhong, X., Nickel, M. D., Kannengiesser, S. A. R., Dale, B. M., Kiefer, B., & Bashir, M. R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25054 · Cited by 216
“[9] (PDFF and R2* values in the units of % and s (1), respectively).”
BackgroundCramér–Rao bounds for three‐point decomposition of water and fat
Pineda, A. R., Reeder, S. B., Wen, Z., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20623 · Cited by 215
“[2]) we begin with the probability density function of the measurements,”
BackgroundHu, H. H., Kim, H., Nayak, K. S., & Goran, M. I. (2010) · Obesity · doi:10.1038/oby.2009.352 · Cited by 212
“In 1984, Dixon described a twodimensional imaging approach that exploited the chemicalshift difference between protons in water and fat to separate the two moieties (14).”
Assessing skeletal muscle mass: historical overview and state of the art
Heymsfield, S. B., Adamek, M., Gonzalez, M. C., Jia, G., & Thomas, D. M. (2014) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1007/s13539-014-0130-5 · Cited by 212
“, Dixon-based fat suppression) [80].”
MR spectroscopic imaging: Principles and recent advances
Posse, S., Otazo, R., Dager, S. R., & Alger, J. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23945 · Cited by 211
Advanced MRI Methods for Assessment of Chronic Liver Disease
Taouli, B., Ehman, R. L., & Reeder, S. B. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2601 · Cited by 197
“In-phase and out-of-phase imaging was first described by Dixon in 1984 [103] and is commonly used for the detection of fat, acquiring in-phase images at a TE of 4.”
MethodNonalcoholic fatty liver disease
Erickson, S. K. (2009) · Journal of Lipid Research · doi:10.1194/jlr.r800089-jlr200 · Cited by 194
Magnetic resonance imaging and spectroscopy for monitoring liver steatosis
Cowin, G. J., Jonsson, J. R., Bauer, J. D., Ash, S., Ali, A., Osland, E. J., Purdie, D. M., Clouston, A. D., Powell, E. E., & Galloway, G. J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21542 · Cited by 191
“Localizer images were used for planning of fast imaging with steady-state precession (FISP) (16), IP/OP (Dixon) images (17) acquired simultaneously, and T2-weighted images FS acquired with T2 half-Fourier acquisition single-shot turbo spin echo (HASTE) with and without FS.”
MethodYu, H., Shimakawa, A., Hines, C. D. G., McKenzie, C. A., Hamilton, G., Sirlin, C. B., Brittain, J. H., & Reeder, S. B. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22840 · Cited by 190
“Alternatively, water–fat separation can be achieved using only the magnitude of the complex source signals (12,13), including the original 2-point ‘‘Dixon’’ method (14).”
BackgroundMagnetic resonance imaging in laboratory petrophysical core analysis
Mitchell, J., Chandrasekera, T. C., Holland, D. J., Gladden, L. F., & Fordham, E. J. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.01.003 · Cited by 188
Disler, D. G., McCauley, T. R., Ratner, L. M., Kesack, C. D., & Cooper, J. A. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.169.5.9353477 · Cited by 187
Metabolic implications of pancreatic fat accumulation
Wagner, R., Eckstein, S. S., Yamazaki, H., Gerst, F., Machann, J., Jaghutriz, B. A., Schürmann, A., Solimena, M., Singer, S., Königsrainer, A., et al. (2022) · Nature Reviews Endocrinology · doi:10.1038/s41574-021-00573-3 · Cited by 185
Multiparametric imaging with heterogeneous radiofrequency fields
Cloos, M. A., Knoll, F., Zhao, T., Block, K. T., Bruno, M., Wiggins, G. C., & Sodickson, D. K. (2016) · Nature Communications · doi:10.1038/ncomms12445 · Cited by 184
Fishbein, M. H., Miner, M., Mogren, C., & Chalekson, J. (2003) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1002/j.1536-4801.2003.tb07958.x · Cited by 178
Willis, T. A., Hollingsworth, K. G., Coombs, A., Sveen, M.-L., Andersen, S., Stojkovic, T., Eagle, M., Mayhew, A., de Sousa, P. L., Dewar, L., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070993 · Cited by 176
“The quantitative Dixon technique allows fat fraction analysis [13], correcting for inhomogeneities in magnetic and radiofrequency fields which make signals on standard T1w images difficult to quantify (see Supporting Information in File S1 for more detail).”
MethodNakayama, T., Yoshimitsu, K., Irie, H., Aibe, H., Tajima, T., Nishie, A., Asayama, Y., Matake, K., Kakihara, D., Matsuura, S., et al. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20369 · Cited by 168
Wokke, B. H., van den Bergen, J. C., Versluis, M. J., Niks, E. H., Milles, J., Webb, A. G., van Zwet, E. W., Aartsma-Rus, A., Verschuuren, J. J., & Kan, H. E. (2014) · Neuromuscular Disorders · doi:10.1016/j.nmd.2014.01.015 · Cited by 166
Machann, J., Thamer, C., Schnoedt, B., Stefan, N., Haring, H., Claussen, C. D., Fritsche, A., & Schick, F. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20825 · Cited by 162
“The Dixon technique (11,12) utilizes the phase shift between water and fat resonances due to their different Larmor frequencies.”
MethodQuadriceps intramuscular fat fraction rather than muscle size is associated with knee osteoarthritis
Kumar, D., Karampinos, D. C., MacLeod, T. D., Lin, W., Nardo, L., Li, X., Link, T. M., Majumdar, S., & Souza, R. B. (2014) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.12.005 · Cited by 160
Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification
Lee, D. H. (2017) · Clinical and Molecular Hepatology · doi:10.3350/cmh.2017.0042 · Cited by 160
Characterisation of liver fat in the UK Biobank cohort
Wilman, H. R., Kelly, M., Garratt, S., Matthews, P. M., Milanesi, M., Herlihy, A., Gyngell, M., Neubauer, S., Bell, J. D., Banerjee, R., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172921 · Cited by 159
“Furthermore the PDFF measurements used in this study were derived from MRI images captured using the DIXON technique [20,21], however the IDEAL method [22] is now considered a more robust and accurate method for measuring liver PDFF, therefore the acquisition sequences used by the UKBiobank have been altered to reflec…”
MethodQuantification of Liver Fat Content with Ultrasound: A WFUMB Position Paper
Ferraioli, G., Berzigotti, A., Barr, R. G., Choi, B. I., Cui, X. W., Dong, Y., Gilja, O. H., Lee, J. Y., Lee, D. H., Moriyasu, F., et al. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.06.002 · Cited by 159
Feasibility of MR-Based Body Composition Analysis in Large Scale Population Studies
West, J., Dahlqvist Leinhard, O., Romu, T., Collins, R., Garratt, S., Bell, J. D., Borga, M., & Thomas, L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163332 · Cited by 158
Fischer, M. A., Pfirrmann, C. W. A., Espinosa, N., Raptis, D. A., & Buck, F. M. (2014) · European Radiology · doi:10.1007/s00330-014-3121-1 · Cited by 112
“This algorithm was shown to provide stable water- and fat-signal separation for dual-echo imaging using phase information to resolve the ambiguity of fat and water signal in chemical-shift imaging [3, 13].”
MethodMRI in the assessment of adipose tissues and muscle composition: how to use it
Huber, F. A., Del Grande, F., Rizzo, S., Guglielmi, G., & Guggenberger, R. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2020.02.06 · Cited by 102
Heusch, P., Buchbender, C., Beiderwellen, K., Nensa, F., Hartung-Knemeyer, V., Lauenstein, T. C., Bockisch, A., Forsting, M., Antoch, G., & Heusner, T. A. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.01.008 · Cited by 96
Costa, D. N., Pedrosa, I., McKenzie, C., Reeder, S. B., & Rofsky, N. M. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3182 · Cited by 87
Machann, J., Bachmann, O. P., Brechtel, K., Dahl, D. B., Wietek, B., Klumpp, B., Häring, H., Claussen, C. D., Jacob, S., & Schick, F. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10255 · Cited by 73
“Besides (1)H MRS, several magnetic resonance imaging (MRI) techniques, such as inversion recovery techniques (18–20), chemical shift selective imaging (21), phase-sensitive techniques (22,23), or spectral spatial excitation (24–29), allow a separate depiction of water or fat component in any site of the human body.”
BackgroundSmall animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Metadata
- Authors
- Dixon, W. T.
- Venue
- Radiology
- Published
- 1984-10
- Volume
- 153
- Issue
- 1
- Pages
- 189-194
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2066125032
- Cited by
- 2,276
- References
- 0
- FWCI
- 31.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.