Flowing cerebrospinal fluid in normal and hydrocephalic states: appearance on MR images.
The DOI matches its Crossref record.
Abstract
The signal intensity of the cerebrospinal fluid (CSF) in the cerebral aqueduct and lateral ventricles on magnetic resonance (MR) images was evaluated in 16 healthy individuals and in 32 patients with various forms of hydrocephalus (20 with chronic normal pressure hydrocephalus [NPH], seven with acute communicating hydrocephalus, and five with hydrocephalus ex vacuo [atrophy]). The low signal intensity frequently observed in the cerebral aqueduct is believed to reflect the pulsatile motion of CSF, which is related to the cardiac cycle. While this "aqueductal flow void phenomenon" can be observed in healthy individuals, it is most pronounced in patients with chronic, communicating NPH; is less evident in patients with acute, communicating hydrocephalus; and is least evident in patients with atrophy. Ventricular compliance is known to be essentially normal in atrophy; mildly decreased in acute, communicating hydrocephalus; and severely decreased in NPH. The degree of aqueductal signal loss is believed to reflect the velocity of the pulsatile CSF motion, which in turn depends on the relative ventricular compliance and surface area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new look at cerebrospinal fluid circulation
Brinker, T., Stopa, E., Morrison, J., & Klinge, P. (2014) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-11-10 · Cited by 819
“It was applied to the study of CSF flow along the aqueduct, a small canal connecting the third and fourth cerebral ventricles [147,148].”
MethodEcho-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
The pulsating brain: A review of experimental and clinical studies of intracranial pulsatility
Wagshul, M. E., Eide, P. K., & Madsen, J. R. (2011) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-8-5 · Cited by 473
Neuroimaging and Early Diagnosis of Alzheimer Disease: A Look to the Future
Petrella, J. R., Coleman, R. E., & Doraiswamy, P. M. (2003) · Radiology · doi:10.1148/radiol.2262011600 · Cited by 427
Radiological assessment of hydrocephalus: new theories and implications for therapy
Greitz, D. (2004) · Neurosurgical Review · doi:10.1007/s10143-004-0326-9 · Cited by 393
To beat or not to beat: roles of cilia in development and disease
Ibanez-Tallon, I. (2003) · Human Molecular Genetics · doi:10.1093/hmg/ddg061 · Cited by 350
Orešković, D., & Klarica, M. (2010) · Brain Research Reviews · doi:10.1016/j.brainresrev.2010.04.006 · Cited by 338
Diagnosis and management of normal-pressure hydrocephalus
Vanneste, J. A. L. (2000) · Journal of Neurology · doi:10.1007/s004150050003 · Cited by 268
Walchenbach, R., Geiger, E., Thomeer, R. T. W. M., & Vanneste, J. A. L. (2002) · PubMed · doi:10.1136/jnnp.72.4.503 · Cited by 234
CSF Flow in the Brain in the Context of Normal Pressure Hydrocephalus
Bradley, W. G. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4124 · Cited by 202
“This outflow results in a normal MR imaging CSF flow void in the aqueduct.(4) The systolic expansion forces CSF and venous blood out of the fixed volume of the skull by the Monro-Kellie hypothesis.”
BackgroundSelf-citationA Model of Pulsations in Communicating Hydrocephalus
Egnor, M., Zheng, L., Rosiello, A., Gutman, F., & Davis, R. (2002) · Pediatric Neurosurgery · doi:10.1159/000063533 · Cited by 201
Luetmer, P. H., Huston, J., Friedman, J. A., Dixon, G. R., Petersen, R. C., Jack, C. R., McClelland, R. L., & Ebersold, M. J. (2002) · Neurosurgery · doi:10.1097/00006123-200203000-00020 · Cited by 198
“However, flow voids on T2-weighted images are dependent on magnetic field strength, slice thickness, TE, and motion compensation techniques, such as cardiac gating and gradient moment nulling, as well as differences between standard spin echo and fast spin echo pulse sequences (4, 18, 32).”
BackgroundBalédent, O., Gondry-Jouet, C., Meyer, M.-E., De Marco, G., Le Gars, D., Henry-Feugeas, M.-C., & Idy-Peretti, I. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000100892.87214.49 · Cited by 195
“Although our spatial resolution was not as good as in specific aqueductal flow studies,6,9 it was as accurate as the resolutions used in other quantitative studies.20,27 In our study, the cervical CSF peak flush occurred earlier in the CH group than in the healthy volunteer group, indicating diminished intracranial co…”
ResultInfluential
Metadata
- Authors
- Bradley, W. G., Kortman, K. E., & Burgoyne, B.
- Venue
- Radiology
- Published
- 1986-06
- Volume
- 159
- Issue
- 3
- Pages
- 611-616
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2144855997
- Cited by
- 236
- References
- 0
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.