Rotator cuff tears: diagnostic performance of MR imaging.
The DOI matches its Crossref record.
Abstract
To determine the diagnostic performance of magnetic resonance (MR) imaging in the evaluation of suspected rotator cuff tears, eight asymptomatic volunteers and 32 patients with rotator cuff tendonopathy who underwent surgery were examined with MR imaging. Twenty-four of these patients also underwent contrast arthrography. The ability of MR imaging to depict the size of cuff tears and the quality of torn tendon edges was also evaluated. The MR imaging and arthrographic studies were reviewed without knowledge of surgical results or of the other studies. A scoring system was developed and a score assigned to each patient's MR study. The sensitivity of MR imaging for all tears (partial and full thickness) was 0.91, and the specificity was 0.88; whereas the sensitivity and specificity of arthrography were each 0.71. The scoring system improved the sensitivity to 1.0 and the specificity to 0.92. Linear regression analysis showed excellent correlation between preoperative assessment of the size of rotator cuff tears and measurement at surgery (r = .95).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Abnormal findings on magnetic resonance images of asymptomatic shoulders.
Sher, J. S., Uribe, J. W., Posada, A., Murphy, B. J., & Zlatkin, M. B. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199501000-00002 · Cited by 1,139
Self-citationde Jesus, J. O., Parker, L., Frangos, A. J., & Nazarian, L. N. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1241 · Cited by 608
Quantitative Assessment of the Muscles of the Rotator Cuff with Magnetic Resonance Imaging
ZANETTI, M., GERBER, C., & HODLER, J. (1998) · INVESTIGATIVE RADIOLOGY · doi:10.1097/00004424-199803000-00006 · Cited by 511
TEEFEY, S. A., RUBIN, D. A., MIDDLETON, W. D., HILDEBOLT, C. F., LEIBOLD, R. A., & YAMAGUCHI, K. (2004) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200404000-00007 · Cited by 476
Diagnostic values of clinical diagnostic tests in subacromial impingement syndrome
Çalış, M., Akgün, K., Birtane, M., Karacan, I., Çalış, H., & Tüzün, F. (2000) · Annals of the Rheumatic Diseases · doi:10.1136/ard.59.1.44 · Cited by 335
Reilly, P., Macleod, I., Macfarlane, R., Windley, J., & Emery, R. (2006) · The Annals of The Royal College of Surgeons of England · doi:10.1308/003588406x94968 · Cited by 309
Lenza, M., Buchbinder, R., Takwoingi, Y., Johnston, R. V., Hanchard, N. C., & Faloppa, F. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009020.pub2 · Cited by 267
Graichen, H., Bonel, H., Stammberger, T., Haubner, M., Rohrer, H., Englmeier, K. H., Reiser, M., & Eckstein, F. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.172.4.10587151 · Cited by 214
Magnetic Resonance Imaging of the Shoulder in Asymptomatic Professional Baseball Pitchers
Miniaci, A., Mascia, A. T., Salonen, D. C., & Becker, E. J. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300012501 · Cited by 200
“The rotator cuff tendons were evaluated according to a modified grading system adopted from Farley et al.,5 Neumann et al.,19 and Zlatkin et al.32 In this classification system, not only was the signal pattern of the tendon evaluated, but also the extent of the signal toward a tendon margin: grade 0 (normal), tendon w…”
BackgroundMR imaging of the rotator cuff: peritendinous and bone abnormalities in an asymptomatic population.
Needell, S. D., Zlatkin, M. B., Sher, J. S., Murphy, B. J., & Uribe, J. W. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.4.8610564 · Cited by 199
Self-citationPainful shoulder: comparison of physical examination and ultrasonographic findings
Naredo, E., Aguado, P., De Miguel, E., Uson, J., Mayordomo, L., Gijon-Baños, J., & Martin-Mola, E. (2002) · Annals of the Rheumatic Diseases · doi:10.1136/ard.61.2.132 · Cited by 190
Is local subacromial corticosteroid injection beneficial in subacromial impingement syndrome?
Akgün, K., Birtane, M., & Akarırmak, Ü. (2004) · Clinical Rheumatology · doi:10.1007/s10067-004-0930-7 · Cited by 113
Frost, P., Andersen, J. H., & Lundorf, E. (1999) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(99)90090-3 · Cited by 63
Metadata
- Authors
- Zlatkin, M. B., Iannotti, J. P., Roberts, M. C., Esterhai, J. L., Dalinka, M. K., Kressel, H. Y., Schwartz, J. S., & Lenkinski, R. E.
- Venue
- Radiology
- Published
- 1989-07
- Volume
- 172
- Issue
- 1
- Pages
- 223-229
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2007499800
- Cited by
- 264
- References
- 0
- FWCI
- 13.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.