The effects of magnetic resonance (MR) pulse sequences and timing parameters on tumor-liver contrast were studied in an animal model of metastatic liver cancer. Six spin-echo (SE), three inversion-recovery (IR), and four gradient-echo (GRE) sequences were evaluated at 0.6 T before and after injection of super-paramagnetic iron oxide. GRE techniques, irrespective of echo time and flip angle, showed the greatest change in signal intensity (enhancement) of the liver after administration of iron oxide. Single-acquisition GRE sequences (16 seconds) matched the contrast-to-noise ratio (C/N) performance of the most effective 6.4-minute SE sequences. Multiexcitation GRE sequences showed tumor-liver C/Ns per unit time that were significantly (P less than .05) higher than those achieved with SE and IR sequences. GRE sequences, which recruit intravoxel dephasing as an additional source of transverse relaxation enhancement (T2*), show a higher C/N per unit time and in this respect seem superior to SE and IR sequences for MR imaging with superparamagnetic iron oxide.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.172.2.2748820

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Fretz, C. J., Elizondo, G., Weissleder, R., Hahn, P. F., Stark, D. D., & Ferrucci, J. T.
Venue
Radiology
Published
1989-08
Volume
172
Issue
2
Pages
393-397
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2077018882
Cited by
78
References
0
FWCI
3.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.