First-pass cardiac perfusion: evaluation with ultrafast MR imaging.
The DOI matches its Crossref record.
Abstract
The authors studied cardiac perfusion by administering gadolinium diethylenetriaminepentaacetic acid (DTPA) in conjunction with an ultrafast imaging technique that produces strongly T1-weighted images. The method consisted of a 180 degrees inversion pulse, followed by a gradient-echo acquisition with a very short repetition time (less than 4 msec). Each image was acquired throughout a small fraction of the cardiac cycle. The method was applied in an isolated perfused rat heart model (acquisition time = 116 msec) and in human subjects without known cardiac disease (acquisition time = 125 msec). Fast, high-resolution images (128 X 128 matrix) were created by combining sequentially acquired small matrixes. After bolus administration of Gd-DTPA in the perfused rat heart model, contrast was pronounced between the nonperfused myocardium and perfused normal myocardium. First-pass wash-in and washout phases of the contrast material were observed in the perfused rat heart model and in human subjects. Results demonstrated the clinical feasibility of first-pass perfusion studies of the heart. The studies can be performed on a conventional whole-body imaging system with standard hardware.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M. (1999) · Circulation · doi:10.1161/01.cir.100.19.1992 · Cited by 2,581
An Improved MR Imaging Technique for the Visualization of Myocardial Infarction
Simonetti, O. P., Kim, R. J., Fieno, D. S., Hillenbrand, H. B., Wu, E., Bundy, J. M., Finn, J. P., & Judd, R. M. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja50215 · Cited by 1,358
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578
Otazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571
MicroRNA therapy stimulates uncontrolled cardiac repair after myocardial infarction in pigs
Gabisonia, K., Prosdocimo, G., Aquaro, G. D., Carlucci, L., Zentilin, L., Secco, I., Ali, H., Braga, L., Gorgodze, N., Bernini, F., et al. (2019) · Nature · doi:10.1038/s41586-019-1191-6 · Cited by 478
Studies of Gd‐DTPA relaxivity and proton exchange rates in tissue
Donahue, K. M., Burstein, D., Manning, W. J., & Gray, M. L. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320110 · Cited by 339
Self-citationMagnetic resonance mapping demonstrates benefits of VEGF–induced myocardial angiogenesis
Pearlman, J. D., Hibberd, M. G., Chuang, M. L., Harada, K., Lopez, J. J., Gladstone, S. R., Friedman, M., Sellke, F. W., & Simons, M. (1995) · Nature Medicine · doi:10.1038/nm1095-1085 · Cited by 326
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Christodoulou, A. G., Shaw, J. L., Nguyen, C., Yang, Q., Xie, Y., Wang, N., & Li, D. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0217-y · Cited by 323
Manning, W. J., Atkinson, D. J., Grossman, W., Paulin, S., & Edelman, R. R. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90754-w · Cited by 305
Self-citationWater diffusion and exchange as they influence contrast enhancement
Donahue, K. M., Weisskoff, R. M., & Burstein, D. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070114 · Cited by 270
Self-citationOn the Applications of Robust PCA in Image and Video Processing
Bouwmans, T., Javed, S., Zhang, H., Lin, Z., & Otazo, R. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2853589 · Cited by 255
Early Contrast-Enhanced MRI Predicts Late Functional Recovery After Reperfused Myocardial Infarction
Rogers, W. J., Kramer, C. M., Geskin, G., Hu, Y.-L., Theobald, T. M., Vido, D. A., Petruolo, S., & Reichek, N. (1999) · Circulation · doi:10.1161/01.cir.99.6.744 · Cited by 244
Cohen, M. S., & Weisskoff, R. M. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90094-3 · Cited by 234
Gerber, B. L., Raman, S. V., Nayak, K., Epstein, F. H., Ferreira, P., Axel, L., & Kraitchman, D. L. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-18 · Cited by 219
“Thus, perfused tissue appears brighter during the first pass of the gadolinium-based contrast agent[5].”
Cardiac MR Imaging: State of the Technology
Finn, J. P., Nael, K., Deshpande, V., Ratib, O., & Laub, G. (2006) · Radiology · doi:10.1148/radiol.2412041866 · Cited by 215
Noninvasive Assessment of Myocardial Perfusion
Salerno, M., & Beller, G. A. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.109.854893 · Cited by 211
Cardiovascular magnetic resonance artefacts
Ferreira, P. F., Gatehouse, P. D., Mohiaddin, R. H., & Firmin, D. N. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-41 · Cited by 191
Functional Magnetic Resonance Imaging in Medicine and Physiology
Moonen, C. T. W., van Zijl, P. C. M., Frank, J. A., Le Bihan, D., & Becker, E. D. (1990) · Science · doi:10.1126/science.2218514 · Cited by 185
Clinical quantitative cardiac imaging for the assessment of myocardial ischaemia
on behalf of the Quantitative Cardiac Imaging Study Group, Dewey, M., Siebes, M., Kachelrieß, M., Kofoed, K. F., Maurovich-Horvat, P., Nikolaou, K., Bai, W., Kofler, A., Manka, R., et al. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0341-8 · Cited by 184
Cardiovascular magnetic resonance imaging: Current and emerging applications
Lima, J. A. C., & Desai, M. Y. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.06.033 · Cited by 183
Metadata
- Authors
- Atkinson, D. J., Burstein, D., & Edelman, R. R.
- Venue
- Radiology
- Published
- 1990-03
- Volume
- 174
- Issue
- 3
- Pages
- 757-762
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2120040975
- Cited by
- 359
- References
- 0
- FWCI
- 13.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.