Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.
The DOI matches its Crossref record.
Abstract
Continuous computed tomographic (CT) scanning of organ volumes during a single breath hold was studied. The authors modified the table feed mechanism of a continuously rotating CT scanner to allow patient transport at low, but accurately controlled, speeds (0.1-11.0 mm/sec) during continuous 1-second scanning. An algorithm was designed to reconstruct artifact-free images for arbitrary table positions from the helical data by interpolating between adjacent scans. Section sensitivity profiles were enlarged; the section width for a 10-mm section and a speed of 10.0 mm/sec was increased by a factor of 1.3, compared with the nominal value. Clinical examples were presented for studies of lung nodules and studies enhanced with contrast medium. Major advantages are the possibility of continuous scanning of extended volumes within a breath-hold period and retrospective, arbitrary selection of anatomic levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study
Huber-Wagner, S., Lefering, R., Qvick, L.-M., Körner, M., Kay, M. V., Pfeifer, K.-J., Reiser, M., Mutschler, W., & Kanz, K.-G. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60232-4 · Cited by 890
Time‐resolved contrast‐enhanced 3D MR angiography
Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360304 · Cited by 877
State of the Art: Iterative CT Reconstruction Techniques
Geyer, L. L., Schoepf, U. J., Meinel, F. G., Nance, J. W., Bastarrika, G., Leipsic, J. A., Paul, N. S., Rengo, M., Laghi, A., & De Cecco, C. N. (2015) · Radiology · doi:10.1148/radiol.2015132766 · Cited by 704
Kalender, W. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r03 · Cited by 689
Self-citationGoldstein, S. A., Evangelista, A., Abbara, S., Arai, A., Asch, F. M., Badano, L. P., Bolen, M. A., Connolly, H. M., Cuéllar-Calàbria, H., Czerny, M., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.11.015 · Cited by 641
Flohr, T., Petersilka, M., Henning, A., Ulzheimer, S., Ferda, J., & Schmidt, B. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.10.030 · Cited by 581
Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Hu, H., He, H. D., Foley, W. D., & Fox, S. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap3755 · Cited by 509
Principles of CT and CT Technology
Goldman, L. W. (2007) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.107.042978 · Cited by 445
Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT
Achenbach, S., Ulzheimer, S., Baum, U., Kachelrieß, M., Ropers, D., Giesler, T., Bautz, W., Daniel, W. G., Kalender, W. A., & Moshage, W. (2000) · Circulation · doi:10.1161/01.cir.102.23.2823 · Cited by 434
Self-citationIterative deblurring for CT metal artifact reduction
Wang, G., Snyder, D. L., O'Sullivan, J. A., & Vannier, M. W. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538943 · Cited by 409
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Micro-Computed Tomography—Current Status and Developments
Ritman, E. L. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140130 · Cited by 360
Radiation Exposure at Chest CT: A Statement of the Fleischner Society
Mayo, J. R., Aldrich, J., & Müller, N. L. (2003) · Radiology · doi:10.1148/radiol.2281020874 · Cited by 359
Mutic, S., Palta, J. R., Butker, E. K., Das, I. J., Huq, M. S., Loo, L.-N. D., Salter, B. J., McCollough, C. H., & Van Dyk, J. (2003) · Medical Physics · doi:10.1118/1.1609271 · Cited by 344
Handbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
Algorithm for image reconstruction in multi-slice helical CT
Taguchi, K., & Aradate, H. (1998) · Medical Physics · doi:10.1118/1.598230 · Cited by 286
Multimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Dual-Modality Imaging: Combining Anatomy and Function
Townsend, D. W. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.051276 · Cited by 282
Automated detection of lung nodules in CT scans: Preliminary results
Armato, S. G., Giger, M. L., & MacMahon, H. (2001) · Medical Physics · doi:10.1118/1.1387272 · Cited by 250
Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures
Müller, R., & Rüegsegger, P. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)91884-j · Cited by 240
Dose in x-ray computed tomography
Kalender, W. A. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/3/r129 · Cited by 235
“The trend continued into the 1990s which began with the introduction of spiral volumetric CT (Kalender et al 1990).”
BackgroundSelf-citationX-ray computed tomography: from medical imaging to dimensional metrology
Villarraga-Gómez, H., Herazo, E. L., & Smith, S. T. (2019) · Precision Engineering · doi:10.1016/j.precisioneng.2019.06.007 · Cited by 233
A PC program for estimating organ dose and effective dose values in computed tomography
Kalender, W. A., Schmidt, B., Zankl, M., & Schmidt, M. (1999) · European Radiology · doi:10.1007/s003300050709 · Cited by 231
Self-citationECG‐correlated image reconstruction from subsecond multi‐slice spiral CT scans of the heart
Kachelrieß, M., Ulzheimer, S., & Kalender, W. A. (2000) · Medical Physics · doi:10.1118/1.1286552 · Cited by 225
Self-citationScharf, J., Chouchane, M., Finegan, D. P., Lu, B., Redquest, C., Kim, M.-C., Yao, W., Franco, A. A., Gostovic, D., Liu, Z., et al. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01081-9 · Cited by 219
Kachelriess, M., & Kalender, W. A. (1998) · Medical Physics · doi:10.1118/1.598453 · Cited by 212
Self-citationPositron Emission Tomography/Computed Tomography
Townsend, D. W. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.003 · Cited by 206
Technical approaches to the optimisation of CT
Kalender, W. A., Buchenau, S., Deak, P., Kellermeier, M., Langner, O., van Straten, M., Vollmar, S., & Wilharm, S. (2008) · Physica Medica · doi:10.1016/j.ejmp.2008.01.012 · Cited by 199
Self-citationComputed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Mahesh, M. (2002) · RadioGraphics · doi:10.1148/radiographics.22.4.g02jl14949 · Cited by 196
Desjardins, B., & Kazerooni, E. A. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.4.1820993 · Cited by 192
Diagnostic criteria for fatty infiltration of the liver on contrast-enhanced helical CT.
Jacobs, J. E., Birnbaum, B. A., Shapiro, M. A., Langlotz, C. P., Slosman, F., Rubesin, S. E., & Horii, S. C. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.3.9725292 · Cited by 181
Relationship between Noise, Dose, and Pitch in Cardiac Multi–Detector Row CT
Primak, A. N., McCollough, C. H., Bruesewitz, M. R., Zhang, J., & Fletcher, J. G. (2006) · RadioGraphics · doi:10.1148/rg.266065063 · Cited by 180
Kawamata, A., Fujishita, M., Ariji, Y., & Ariji, E. (2000) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/s1079-2104(00)70089-8 · Cited by 168
Rubin, G. D., Walker, P. J., Dake, M. D., Napel, S., Jeffrey, R. B., McDonnell, C. H., Mitchell, R. S., & Miller, D. C. (1993) · Journal of Vascular Surgery · doi:10.1016/0741-5214(93)90075-w · Cited by 166
Van Hoe, L., Gryspeerdt, S., Marchal, G., Baert, A. L., & Mertens, L. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.165.6.7484581 · Cited by 159
Diagnostic Performance of Multidetector Computed Tomography for Suspected Acute Appendicitis
Pickhardt, P. J., Lawrence, E. M., Pooler, B. D., & Bruce, R. J. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-12-201106210-00006 · Cited by 158
“The introduction of single-detector spiral or helical CT in the 1990s allowed for volumetric imaging with improved diagnostic capabilities (6).”
BackgroundApplication of the Suchey-Brooks method to three-dimensional imaging of the pubic symphysis
Telmon, N., Gaston, A., Chemla, P., Blanc, A., Joffre, F., & Rougé, D. (2005) · Journal of Forensic Sciences · doi:10.1520/jfs2004326 · Cited by 101
Hagspiel, K. D., Flors, L., Hanley, M., & Norton, P. T. (2015) · Techniques in Vascular and Interventional Radiology · doi:10.1053/j.tvir.2014.12.002 · Cited by 88
“Multidetector CTA (MDCTA) allows the acquisition of a 3-dimensional (3D)volume during the peak enhancement phase of the vessels of interest following intravenous injection of iodinated contrast material.(5,6) State-of-the-art CT systems have gantry rotation times under 300 ms and can cover the entire abdomen and pelvi…”
Roski, F., Hammel, J., Mei, K., Baum, T., Kirschke, J. S., Laugerette, A., Kopp, F. K., Bodden, J., Pfeiffer, D., Pfeiffer, F., et al. (2019) · European Radiology · doi:10.1007/s00330-019-06263-z · Cited by 70
Metadata
- Authors
- Kalender, W. A., Seissler, W., Klotz, E., & Vock, P.
- Venue
- Radiology
- Published
- 1990-07
- Volume
- 176
- Issue
- 1
- Pages
- 181-183
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2028648047
- Cited by
- 1,036
- References
- 0
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.