Preclinical evaluation of Gd-EOB-DTPA as a contrast agent in MR imaging of the hepatobiliary system.
The DOI matches its Crossref record.
Abstract
Gadolinium diethylenetriaminepentaacetic acid (DTPA) covalently linked to the lipophilic ethoxybenzyl moiety (Gd-EOB-DTPA) was designed for use as a contrast agent in hepatobiliary magnetic resonance imaging. With T1 relaxivity values of 8.7 L/mmol.second in plasma and 16.6 L/mmol.second in rat liver tissue and a median lethal dose of 10 mmol/kg when administered intravenously in mice and rats, Gd-EOB-DTPA has a fairly high margin of safety. In rats and monkeys, biodistribution studies performed 7 days after administration of 0.25 mmol/kg revealed very little retention of gadolinium (less than 1%) in the tissues, indicating complete elimination via renal and biliary excretion. Biliary excretion was inhibited by coadministration of sulfobromophthalein, indicating the involvement of a carrier-mediated transport system based on the enzyme glutathione-S-transferase. In rats, the biliary transport maximum was 5 mumol gadolinium/min.kg. High T1 relaxivity of Gd-EOB-DTPA in rat liver in vivo can be explained by transient interaction with intracellular components and by increased microviscosity inside the hepatocyte.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
Rohrer, M., Bauer, H., Mintorovitch, J., Requardt, M., & Weinmann, H.-J. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000184756.66360.d3 · Cited by 1,682
Self-citationVillaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Classification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Metal-Based X-ray Contrast Media
Yu, S.-B., & Watson, A. D. (1999) · Chemical Reviews · doi:10.1021/cr980441p · Cited by 433
Primovist, Eovist: What to expect?
Van Beers, B. E., Pastor, C. M., & Hussain, H. K. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2012.01.031 · Cited by 407
Huppertz, A., Balzer, T., Blakeborough, A., Breuer, J., Giovagnoni, A., Heinz-Peer, G., Laniado, M., Manfredi, R. M., Mathieu, D. G., Mueller, D., et al. (2004) · Radiology · doi:10.1148/radiol.2301020269 · Cited by 396
Ringe, K. I., Husarik, D. B., Sirlin, C. B., & Merkle, E. M. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4392 · Cited by 388
For the European EOB-study group, Hammerstingl, R., Huppertz, A., Breuer, J., Balzer, T., Blakeborough, A., Carter, R., Fusté, L. C., Heinz-Peer, G., Judmaier, W., et al. (2008) · European Radiology · doi:10.1007/s00330-007-0716-9 · Cited by 384
Huppertz, A., Haraida, S., Kraus, A., Zech, C. J., Scheidler, J., Breuer, J., Helmberger, T. K., & Reiser, M. F. (2005) · Radiology · doi:10.1148/radiol.2342040278 · Cited by 370
Kitao, A., Zen, Y., Matsui, O., Gabata, T., Kobayashi, S., Koda, W., Kozaka, K., Yoneda, N., Yamashita, T., Kaneko, S., et al. (2010) · Radiology · doi:10.1148/radiol.10092214 · Cited by 340
Contrast Agents for MR Imaging of the Liver
Semelka, R. C., & Helmberger, T. K. G. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja2427 · Cited by 337
Reimer, P., Schneider, G., & Schima, W. (2004) · European Radiology · doi:10.1007/s00330-004-2236-1 · Cited by 287
Metal complexes as diagnostic tools
Reichert, D. E., Lewis, J. S., & Anderson, C. J. (1999) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(98)00207-0 · Cited by 263
Kobayashi, H., Kawamoto, S., Jo, S.-K., Bryant, H. L., Brechbiel, M. W., & Star, R. A. (2003) · Bioconjugate Chemistry · doi:10.1021/bc025633c · Cited by 262
Kitao, A., Matsui, O., Yoneda, N., Kozaka, K., Shinmura, R., Koda, W., Kobayashi, S., Gabata, T., Zen, Y., Yamashita, T., et al. (2011) · European Radiology · doi:10.1007/s00330-011-2165-8 · Cited by 258
Ichikawa, T., Saito, K., Yoshioka, N., Tanimoto, A., Gokan, T., Takehara, Y., Kamura, T., Gabata, T., Murakami, T., Ito, K., et al. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181caea5b · Cited by 234
van Montfoort, J. E., Stieger, B., Meijer, D. K. F., Weinmann, H.-J., Meier, P. J., & Fattinger, K. E. (1999) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)34879-7 · Cited by 223
“Gadoxetate is in phase III of clinical trials and has been evaluated for the detection of liver metastases, hepatocellular carcinomas, hemangiomas, and cholestasis (Schuhmann-Giampieri et al., 1992; Ni et al., 1994; Vogl et al., 1996; Reimer et al., 1997; Schmitz et al., 1997).”
InfluentialSelf-citationGadobenate Dimeglumine (Gd-BOPTA): An Overview
KIRCHIN, M. A., PIROVANO, G. P., & SPINAZZI, A. (1998) · Investigative Radiology · doi:10.1097/00004424-199811000-00003 · Cited by 218
Cruite, I., Schroeder, M., Merkle, E. M., & Sirlin, C. B. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4538 · Cited by 205
“Previous reports have suggested that liver enzymes, such as glutathione-S-transferase (an intracellular transport protein for Gd-EOB-DTPA [7]) play a role in the paradoxical contrast uptake by HCCs [29], whereas a more recent small human study suggested that the uptake is determined by expression of OATP1B3 receptors,…”
BackgroundWatanabe, H., Kanematsu, M., Goshima, S., Kondo, H., Onozuka, M., Moriyama, N., & Bae, K. T. (2011) · Radiology · doi:10.1148/radiol.10100621 · Cited by 189
Gadoxetate acid-enhanced MR imaging for HCC: A review for clinicians
Chanyaputhipong, J., Low, S.-C. A., & Chow, P. K. H. (2011) · International Journal of Hepatology · doi:10.4061/2011/489342 · Cited by 41
Metadata
- Authors
- Schuhmann-Giampieri, G., Schmitt-Willich, H., Press, W. R., Negishi, C., Weinmann, H. J., & Speck, U.
- Venue
- Radiology
- Published
- 1992-04
- Volume
- 183
- Issue
- 1
- Pages
- 59-64
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1964911576
- Cited by
- 380
- References
- 0
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.