CoChat

A new macromolecule as a contrast agent for MR angiography: preparation, properties, and animal studies.

Bogdanov, A A, Weissleder, R, Frank, H W, Bogdanova, A V, Nossif, N, Schaffer, B K, Tsai, E, Papisov, M I, Brady, T J · 1993 · Radiology
Cited by 182

The DOI matches its Crossref record.

Abstract

The authors developed and evaluated a polymer as a contrast agent for magnetic resonance (MR) angiography. The agent consists of a monomethoxy ether of poly(ethylene glycol) covalently attached to poly(L-lysine) (PL), with PL serving as the carrier of gadolinium diethylenetriaminepentaacetic acid (DTPA). Immunogenicity and toxicity studies were performed in mice, and biokinetic and metabolic studies were performed in rats. Dose response studies were performed with a three-dimensional time-of-flight sequence in eight rats. No permanent immune response was elicited against Gd-DTPA or the carrier molecule, and accumulation in organs of the reiculoendothelial system was minimal. The blood half-life of the agent was 14 hours. A dose of 20 mumol of gadolinium per kilogram of body weight was sufficient to increase the vessel-muscle ratio by four- to fivefold. Contrast was substantially improved and remained unchanged 2 hours after contrast medium administration, and good visualization of four orders of vasculature was allowed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.187.3.8497616

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Bogdanov, A. A., Weissleder, R., Frank, H. W., Bogdanova, A. V., Nossif, N., Schaffer, B. K., Tsai, E., Papisov, M. I., & Brady, T. J.
Venue
Radiology
Published
1993-06
Volume
187
Issue
3
Pages
701-706
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2040831503
Cited by
182
References
0
FWCI
8.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.