Percutaneous inferior vena caval filters: follow-up of seven designs in 320 patients.
The DOI matches its Crossref record.
Abstract
Three hundred twenty-four percutaneous inferior vena caval (IVC) filters of different designs were placed in 320 patients from April 1985 through June 1992. No acute mortality or substantial morbidity was attributed to filter placement. Radiologic or pathologic follow-up data were obtained in 227 (71%) patients (230 filters); clinical follow-up data only were obtained in 50 (16%) patients (50 filters). One hundred twenty (43%) patients died; post-filter-placement pulmonary emboli (PE) were related to the cause of death in eight. At IVC filter imaging studies, 26 of 137 (19%) filters demonstrated caval thrombus; 12 of 132 (9%) filters had delayed penetration through the IVC wall of greater than 3 mm; 13 of 230 (6%) filters migrated more than 1 cm; and five of 230 (2%) filters had fracture of a strut or leg. Deep venous thrombosis (DVT) at the insertion puncture site or in the lower extremity was noted in 26 of 117 (22%) cases of filter placement. Among patients without imaging studies, clinical suspicion of complications included PE in four patients, IVC thrombus in 14 patients, and lower-extremity DVT in 10 patients. Long-term clinical and radiologic follow-up of all IVC filters is indicated due to the relatively high prevalence of some complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Rogers, F. B., Cipolle, M. D., Velmahos, G., Rozycki, G., & Luchette, F. A. (2002) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200207000-00032 · Cited by 713
Vena caval filters: a comprehensive review
Streiff, M. B. (2000) · Blood · doi:10.1182/blood.v95.12.3669 · Cited by 370
Inferior Vena Caval Filters: Review of a 26-year Single-Center Clinical Experience
Athanasoulis, C. A., Kaufman, J. A., Halpern, E. F., Waltman, A. C., Geller, S. C., & Fan, C.-M. (2000) · Radiology · doi:10.1148/radiology.216.1.r00jl1254 · Cited by 370
Caplin, D. M., Nikolic, B., Kalva, S. P., Ganguli, S., Saad, W. E. A., & Zuckerman, D. A. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2011.07.012 · Cited by 278
The role of vena caval filters in the management of venous thromboembolism
HANN, C., & STREIFF, M. (2005) · Blood Reviews · doi:10.1016/j.blre.2004.08.002 · Cited by 202
White, R. H., Zhou, H., Kim, J., & Romano, P. S. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.13.2033 · Cited by 195
“However, an increasing number of vena cava filters are being used in patients with venous thromboembolism who meet less strictly defined indications, such as medically unstable patients, those with a large burden of clot, and patients deemed to be at increased risk for recurrent thromboembolism or anticoagulant-relate…”
BackgroundEvidence-based evaluation of inferior vena cava filter complications based on filter type
Idakoji, I., Kuo, W., & Deso, S. (2016) · Seminars in Interventional Radiology · doi:10.1055/s-0036-1583208 · Cited by 93
Metadata
- Authors
- Ferris, E. J., McCowan, T. C., Carver, D. K., & McFarland, D. R.
- Venue
- Radiology
- Published
- 1993-09
- Volume
- 188
- Issue
- 3
- Pages
- 851-856
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2011389832
- Cited by
- 301
- References
- 0
- FWCI
- 9.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.