Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 370

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Inferior Vena Caval Filters: Review of a 26-year Single-Center Clinical Experience

Athanasoulis, Christos A., Kaufman, John A., Halpern, Elkan F., Waltman, Arthur C., Geller, Stuart C., Fan, Chieh-Min·2000·Radiology

Abstract

PURPOSE: To review a 26-year single-center clinical experience with inferior vena caval filters. MATERIALS AND METHODS: During 1973-1998, 1,765 filters were implanted in 1,731 patients. Hospital files were reviewed, and data were collected about the indications, safety, effectiveness, numbers, and types of caval filters. Fatal post-filter pulmonary embolism (PE) was considered the primary outcome. Morbidity and mortality were determined as secondary outcomes. Survival and morbidity-free survival curves were calculated. RESULTS: The prevalence of observed post-filter PE was 5.6%. It was fatal in 3.7% of patients. In most patients, fatal PE occurred soon after filter insertion (median, 4.0 days; 95% CI: 2.2, 5.8 days). Major complications occurred in 0.3% of procedures. The prevalence of observed post-filter caval thrombosis was 2.7%. The 30-day mortality rate was 17.0% overall, higher among patients with neoplasms (19.5%) as compared with those without neoplasms (14.3%; P =.004). Filter efficacy and associated morbidity were not different in 46 patients with suprarenal filters. The rate of filters placed for prophylaxis was 4.7% overall and increased to 16.4% in 1998. From 1980 to 1996, there was a fivefold increase in the number of caval filter implants. In recent years, more filters were implanted in younger patients. CONCLUSION: Inferior vena caval filters provide protection from life-threatening PE, with minimal morbidity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.216.1.r00jl1254

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 370

Metadata

Authors
Athanasoulis, C. A., Kaufman, J. A., Halpern, E. F., Waltman, A. C., Geller, S. C., & Fan, C.-M.
Venue
Radiology
Published
2000-07
Volume
216
Issue
1
Pages
54-66
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2028593097
Cited by
370
References
13
FWCI
8.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inferior Vena Caval Filters: Review of a 26-year Single-Center Clinical Experience. https://app.cochat.ai/papers/10.1148/radiology.216.1.r00jl1254
The paper
Athanasoulis, C. A., Kaufman, J. A., Halpern, E. F., Waltman, A. C., Geller, S. C., & Fan, C.-M. (2000). Inferior Vena Caval Filters: Review of a 26-year Single-Center Clinical Experience. Radiology. https://doi.org/10.1148/radiology.216.1.r00jl1254

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.