Standardized uptake values of normal tissues at PET with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose: variations with body weight and a method for correction.
The DOI matches its Crossref record.
Abstract
PURPOSE: To study the relationship between standardized uptake values (SUVs) in normal tissues and body weight determined with positron emission tomography (PET). MATERIALS AND METHODS: SUVs were determined in 28 nondiabetic women with newly diagnosed untreated primary breast cancers. Body weights ranged from 45 to 107 kg. SUVs for lung, liver, marrow, spleen, blood, and normal breast were determined from images obtained with PET 50-60 minutes after injection of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG). RESULTS: There was a positive correlation between SUV and body weight for blood, (r = .75, P = .000004), liver (r = .72, P = .000081), and spleen (r = .57, P = .033), all of which had substantial F-18 activity. In heavy patients, SUVs for those normal tissues were up to twice those of lighter patients. Calculating SUV on the basis of predicted lean body mass (SUV-Lean) eliminated the weight dependence of the SUV for blood (r = .26, P = .18) and reduced weight dependence in other tissues. CONCLUSION: SUV-Lean is a weight-independent index for blood FDG accumulation at PET and may be more appropriate than SUV for quantifying F-18 activity in tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
“usually somewhat less than) SUVs normalized on the basis of total body mass (30,102,103).”
BackgroundSelf-citationYoung, H., Baum, R., Cremerius, U., Herholz, K., Hoekstra, O., Lammertsma, A. A., Pruim, J., & Price, P. (1999) · European Journal of Cancer · doi:10.1016/s0959-8049(99)00229-4 · Cited by 1,720
Pitfalls in Oncologic Diagnosis with FDG PET Imaging: Physiologic and Benign Variants
Shreve, P. D., Anzai, Y., & Wahl, R. L. (1999) · RadioGraphics · doi:10.1148/radiographics.19.1.g99ja0761 · Cited by 827
Self-citationGold Nanocages as Photothermal Transducers for Cancer Treatment
Chen, J., Glaus, C., Laforest, R., Zhang, Q., Yang, M., Gidding, M., Welch, M. J., & Xia, Y. (2010) · Small · doi:10.1002/smll.200902216 · Cited by 691
Progress and Promise of FDG-PET Imaging for Cancer Patient Management and Oncologic Drug Development
Kelloff, G. J., Hoffman, J. M., Johnson, B., Scher, H. I., Siegel, B. A., Cheng, E. Y., Cheson, B. D., O'Shaughnessy, J., Guyton, K. Z., Mankoff, D. A., et al. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-2626 · Cited by 671
A Systematic Review of the Factors Affecting Accuracy of SUV Measurements
Adams, M. C., Turkington, T. G., Wilson, J. M., & Wong, T. Z. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4923 · Cited by 662
“If SUVweight is used in monitoring response, then weight should be measured with the same scale at the PET facility—not on the basis of self-reported weight or from the patient chart.”
BackgroundInfluentialHofmann, M., Maecke, H., Börner, A., Weckesser, E., Schöffski, P., Oei, M., Schumacher, J., Henze, M., Heppeler, A., Meyer, G., et al. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100639 · Cited by 544
Mapping of human brown adipose tissue in lean and obese young men
Leitner, B. P., Huang, S., Brychta, R. J., Duckworth, C. J., Baskin, A. S., McGehee, S., Tal, I., Dieckmann, W., Gupta, G., Kolodny, G. M., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705287114 · Cited by 530
Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose
Rigo, P., Paulus, P., Kaschten, B. J., Hustinx, R., Bury, T., Jerusalem, G., Benoit, T., & Foidart-Willems, J. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01249629 · Cited by 501
FDG PET of Infection and Inflammation
Love, C., Tomas, M. B., Tronco, G. G., & Palestro, C. J. (2005) · RadioGraphics · doi:10.1148/rg.255045122 · Cited by 484
Huang, (. S.-C. (2000) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(00)00155-4 · Cited by 458
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
Kunkel, M., Reichert, T. E., Benz, P., Lehr, H., Jeong, J., Wieand, S., Bartenstein, P., Wagner, W., & Whiteside, T. L. (2003) · Cancer · doi:10.1002/cncr.11159 · Cited by 390
A review on segmentation of positron emission tomography images
Foster, B., Bagci, U., Mansoor, A., Xu, Z., & Mollura, D. J. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.014 · Cited by 370
Römer, W., Hanauske, A.-R., Ziegler, S. I., Thödtmann, R., Weber, W., Fuchs, C., Enne, W., Herz, M., Nerl, C., Garbrecht, M., et al. (1998) · PubMed · doi:10.1182/blood.v91.12.4464 · Cited by 335
FDG PET of Primary Benign and Malignant Bone Tumors: Standardized Uptake Value in 52 Lesions
Aoki, J., Watanabe, H., Shinozaki, T., Takagishi, K., Ishijima, H., Oya, N., Sato, N., Inoue, T., & Endo, K. (2001) · Radiology · doi:10.1148/radiology.219.3.r01ma08774 · Cited by 318
Positron Emission Tomography (PET) in Oncology
Gallamini, A., Zwarthoed, C., & Borra, A. (2014) · Cancers · doi:10.3390/cancers6041821 · Cited by 312
Moog, F., Bangerter, M., Kotzerke, J., Guhlmann, A., Frickhofen, N., & Reske, S. N. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.2.603 · Cited by 277
Dynamic whole-body PET imaging: principles, potentials and applications
Rahmim, A., Lodge, M. A., Karakatsanis, N. A., Panin, V. Y., Zhou, Y., McMillan, A., Cho, S., Zaidi, H., Casey, M. E., & Wahl, R. L. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4153-6 · Cited by 273
Self-citationCancer Response Criteria and Bone Metastases: RECIST 1.1, MDA and PERCIST
Costelloe, C. M., Chuang, H. H., Madewell, J. E., & Ueno, N. T. (2010) · Journal of Cancer · doi:10.7150/jca.1.80 · Cited by 270
Infection imaging using whole-body FDG-PET
Stumpe, K. D. M., Dazzi, H., Schaffner, A., & von Schulthess, G. K. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000277 · Cited by 266
Sugawara, Y., Zasadny, K. R., Neuhoff, A. W., & Wahl, R. L. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv37521 · Cited by 265
Self-citationHoekstra, C. J., Paglianiti, I., Hoekstra, O. S., Smit, E. F., Postmus, P. E., Teule, G. J. J., & Lammertsma, A. A. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050570 · Cited by 251
Karakatsanis, N. A., Lodge, M. A., Tahari, A. K., Zhou, Y., Wahl, R. L., & Rahmim, A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/20/7391 · Cited by 247
“The parametric Ki values in background regions of relatively constant but high activity have been shown to approach ‘zero’ unlike background SUV values (Zasadny and Wahl 1993), resulting in enhanced tumor contrast in Ki images.”
BackgroundInfluentialSelf-citationSugawara, Y., Braun, D. K., Kison, P. V., Russo, J. E., Zasadny, K. R., & Wahl, R. L. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050290 · Cited by 236
Self-citationFluorodeoxyglucose Uptake in the Aortic Wall at PET/CT: Possible Finding for Active Atherosclerosis
Tatsumi, M., Cohade, C., Nakamoto, Y., & Wahl, R. L. (2003) · Radiology · doi:10.1148/radiol.2293021168 · Cited by 222
Self-citationEvaluation of 18F‐2‐deoxy‐2‐fluoro‐d‐glucose Positron Emission Tomography for Gastric Cancer
Mochiki, E., Kuwano, H., Katoh, H., Asao, T., Oriuchi, N., & Endo, K. (2004) · World Journal of Surgery · doi:10.1007/s00268-003-7191-5 · Cited by 221
Australia and New Zealand Dialysis and Transplant Registry
McDonald, S. P. (2015) · Kidney International Supplements · doi:10.1038/kisup.2015.8 · Cited by 219
PET in oncology: Will it replace the other modalities?
Hoh, C. K., Schiepers, C., Seltzer, M. A., Gambhir, S. S., Silverman, D. H. S., Czernin, J., Maddahi, J., & Phelps, M. E. (1997) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(97)80042-6 · Cited by 211
Saunders, C. A. B., Dussek, J. E., O’Doherty, M. J., & Maisey, M. N. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(98)01257-0 · Cited by 201
Sugawara, Y., Fisher, S. J., Zasadny, K. R., Kison, P. V., Baker, L. H., & Wahl, R. L. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.1.173 · Cited by 199
Self-citation[18F]3′-deoxy-3′-fluorothymidine PET for the diagnosis and grading of brain tumors
Choi, S. J., Kim, J. S., Kim, J. H., Oh, S. J., Lee, J. G., Kim, C. J., Ra, Y. S., Yeo, J. S., Ryu, J. S., & Moon, D. H. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1742-3 · Cited by 189
Tumor-Specific Positron Emission Tomography Imaging in Patients: [18F] Fluorodeoxyglucose and Beyond
Mankoff, D. A., Eary, J. F., Link, J. M., Muzi, M., Rajendran, J. G., Spence, A. M., & Krohn, K. A. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-0074 · Cited by 175
FDG-PET imaging in mild traumatic brain injury: a critical review
Byrnes, K. R., Wilson, C. M., Brabazon, F., von Leden, R., Jurgens, J. S., Oakes, T. R., & Selwyn, R. G. (2014) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2013.00013 · Cited by 171
Monitoring response to treatment in patients utilizing PET
Avril, N. E., & Weber, W. A. (2005) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2004.09.006 · Cited by 171
Comparison of simplified quantitative analyses of FDG uptake
Graham, M. M., Peterson, L. M., & Hayward, R. M. (2000) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(00)00143-8 · Cited by 169
Utech, C. I., Young, C. S., & Winter, P. F. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01249621 · Cited by 165
“Differential uptake ratio (DUR) was calculated for axillary nodal uptake, utilizing a previously described methodology [22].”
Methodde Wit, M., Bumann, D., Beyer, W., Herbst, K., Clausen, M., & Hossfeld, D. K. (1997) · Annals of Oncology · doi:10.1093/annonc/8.suppl_1.s57 · Cited by 164
(2004) · PubMed · Cited by 141
Büsing, K. A., Schönberg, S. O., Brade, J., & Wasser, K. (2013) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2012.10.014 · Cited by 111
“It has been reported that SUV generated by normalization of F-FDG uptake to patient total body weight (SUVTBW) overestimates F-FDG uptake in heavy patients as their fraction of body fat (with low FDG uptake) is often increased [43].”
BackgroundRole of Optimal Quantification of FDG PET Imaging in the Clinical Practice of Radiology
Ziai, P., Hayeri, M. R., Salei, A., Salavati, A., Houshmand, S., Alavi, A., & Teytelboym, O. M. (2016) · RadioGraphics · doi:10.1148/rg.2016150102 · Cited by 106
(2005) · PubMed · Cited by 103
Low-count whole-body PET with deep learning in a multicenter and externally validated study
Chaudhari, A. S., Mittra, E., Davidzon, G. A., Gulaka, P., Gandhi, H., Brown, A., Zhang, T., Srinivas, S., Gong, E., Zaharchuk, G., et al. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00497-2 · Cited by 83
Effects of blood glucose level on 18F-FDG uptake for PET/CT in normal organs: A systematic review
Sprinz, C., Altmayer, S., Zanon, M., Watte, G., Irion, K., Marchiori, E., & Hochhegger, B. (2018) · PLOS ONE · doi:10.1371/journal.pone.0193140 · Cited by 82
Sprinz, C., Zanon, M., Altmayer, S., Watte, G., Irion, K., Marchiori, E., & Hochhegger, B. (2018) · Scientific Reports · doi:10.1038/s41598-018-20529-4 · Cited by 59
PET/CT mediastinal and liver FDG uptake: Effects of biological and procedural factors
Malladi, A., Viner, M., Jackson, T., Mercier, G., & Subramaniam, R. M. (2013) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.12015 · Cited by 35
Comparison of FDG-PET/CT images between chronic renal failure patients on hemodialysis and controls.
(2015) · Europe PMC (PubMed Central) · Cited by 19
Zhao, J., Xue, Q., Chen, X., You, Z., Wang, Z., Yuan, J., Liu, H., & Hu, L. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00363-w · Cited by 12
Metadata
- Authors
- Zasadny, K. R., & Wahl, R. L.
- Venue
- Radiology
- Published
- 1993-12
- Volume
- 189
- Issue
- 3
- Pages
- 847-850
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1987002881
- Cited by
- 635
- References
- 0
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.