Pancreatic tumors: evaluation with endoscopic US, CT, and MR imaging.

Müller, M F, Meyenberger, C, Bertschinger, P, Schaer, R, Marincek, B · 1994 · Radiology
Cited by 499

The DOI matches its Crossref record.

Abstract

PURPOSE: To compare the value of endosonography (endoscopic ultrasound [US]), dynamic computed tomography (CT), and magnetic resonance (MR) imaging in the evaluation of pancreatic tumors. MATERIALS AND METHODS: Forty-nine consecutive patients with clinical suspicion of pancreatic tumor underwent endoscopic US (n = 49), CT (n = 46), and MR imaging (n = 25). The final diagnosis of a malignant (n = 22), benign (n = 2), or inflammatory (n = 9) tumor, or no (n = 16) tumor was made at surgery (n = 28) and/or a combination of biopsy (n = 9) and 9-24-month follow-up (n = 12). RESULTS: The sensitivity was 94% for endoscopic US, 69% for CT, and 83% for MR imaging. Specificity was 100% for endoscopic US, 64% for CT, and 100% for MR imaging. Accuracy was 96% for endoscopic US, 67% for CT, and 84% for MR imaging. The sensitivity for the detection of tumors less than 3 cm in diameter was 93% for endoscopic US (n = 15), 53% for CT (n = 15), and 67% for MR imaging (n = 12). CONCLUSION: Endoscopic US is more accurate than dynamic CT and MR imaging in the diagnosis of pancreatic tumor, particularly for tumors less than 3 cm in diameter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.190.3.8115622

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Müller, M. F., Meyenberger, C., Bertschinger, P., Schaer, R., & Marincek, B.
Venue
Radiology
Published
1994-03
Volume
190
Issue
3
Pages
745-751
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2064027311
Cited by
499
References
0
FWCI
6.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.