Hepatic hemangiomas: a multi-institutional study of appearance on T2-weighted and serial gadolinium-enhanced gradient-echo MR images.
The DOI matches its Crossref record.
Abstract
PURPOSE: To define the appearance of hepatic hemangiomas on T2-weighted and serial gadolinium-enhanced gradient-echo magnetic resonance (MR) images. MATERIALS AND METHODS: In four university hospitals, with 1.0- or 1.5-T MR imaging, T2-weighted and T1-weighted gradient-echo images were obtained in 66 adult patients before and at 1, 45, and 90 seconds and 10 minutes after injection of a gadolinium chelate. Hemangiomas were categorized as small (< 1.5-cm-diameter), medium (1.5-5.0-cm), and large (> 5.0-cm) tumors. RESULTS: In all, 154 hemangiomas were depicted (81 small, 56 medium, and 17 large tumors). All 154 lesions were hyperintense on T2-weighted images. Three patterns of contrast enhancement were observed: (a) uniform enhancement at 1 second (35 of 81 small lesions and no medium or large lesions), (b) peripheral nodular enhancement progressing centripetally to uniform enhancement (75 of all 154 lesions), and (c) peripheral nodular enhancement with persistent hypointensity centrally (44 of all 154 lesions, including 16 of 17 large lesions). CONCLUSION: Three patterns of enhancement of hemangiomas were observed. High signal intensity on T2-weighted images provided complementary information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
EASL Clinical Practice Guidelines on the management of benign liver tumours
(2016) · Journal of Hepatology · doi:10.1016/j.jhep.2016.04.001 · Cited by 534
Grazioli, L., Morana, G., Kirchin, M. A., & Schneider, G. (2005) · Radiology · doi:10.1148/radiol.2361040338 · Cited by 354
Contrast Agents for MR Imaging of the Liver
Semelka, R. C., & Helmberger, T. K. G. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja2427 · Cited by 337
Self-citationKrinsky, G. A., Lee, V. S., Theise, N. D., Weinreb, J. C., Rofsky, N. M., Diflo, T., & Teperman, L. W. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma40445 · Cited by 332
Reimer, P., Schneider, G., & Schima, W. (2004) · European Radiology · doi:10.1007/s00330-004-2236-1 · Cited by 287
Gadobenate Dimeglumine (Gd-BOPTA): An Overview
KIRCHIN, M. A., PIROVANO, G. P., & SPINAZZI, A. (1998) · Investigative Radiology · doi:10.1097/00004424-199811000-00003 · Cited by 218
d’Assignies, G., Fina, P., Bruno, O., Vullierme, M.-P., Tubach, F., Paradis, V., Sauvanet, A., Ruszniewski, P., & Vilgrain, V. (2013) · Radiology · doi:10.1148/radiol.13121628 · Cited by 212
Spinazzi, A., Lorusso, V., Pirovano, G., & Kirchin, M. (1999) · Academic Radiology · doi:10.1016/s1076-6332(99)80451-6 · Cited by 204
Utility of diffusion‐weighted MRI in distinguishing benign and malignant hepatic lesions
Miller, F. H., Hammond, N., Siddiqi, A. J., Shroff, S., Khatri, G., Wang, Y., Merrick, L. B., & Nikolaidis, P. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22235 · Cited by 188
Taouli, B., Sandberg, A., Stemmer, A., Parikh, T., Wong, S., Xu, J., & Lee, V. S. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21876 · Cited by 167
Time to Progression of Pancreatic Cancer: Evaluation with Multi-Detector Computed Tomography
Ahn, S. J., Choi, S. J., & Kim, H. S. (2017) · Journal of Gastrointestinal Cancer · doi:10.1007/s12029-016-9876-7 · Cited by 32
Metadata
- Authors
- Semelka, R. C., Brown, E. D., Ascher, S. M., Patt, R. H., Bagley, A. S., Li, W., Edelman, R. R., Shoenut, J. P., & Brown, J. J.
- Venue
- Radiology
- Published
- 1994-08
- Volume
- 192
- Issue
- 2
- Pages
- 401-406
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2023972266
- Cited by
- 309
- References
- 0
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.