Coronary artery stenoses: three-dimensional imaging with electrocardiographically triggered, contrast agent-enhanced, electron-beam CT.
The DOI matches its Crossref record.
Abstract
PURPOSE: To compare electron-beam computed tomography (CT) and coronary angiography for depiction of coronary artery stenoses. MATERIALS AND METHODS: In 27 patients (age range, 50-70 years), electrocardiographically triggered axial electron-beam CT scans of the heart were obtained during breath hold and intravenous administration of contrast agent. Coronary arteries were reconstructed three-dimensionally. Electron-beam CT and angiographic results were compared. RESULTS: Significant enhancement within the vessel lumen (P < .001) permitted selective reconstruction of the inner coronary artery lumen. Nine of 11 high-grade stenoses and all five occlusions in the proximal left anterior descending artery and three of five high-grade right coronary artery stenoses were clearly identified. Recognition of stenosis of the left circumflex artery was not reliable. Success after percutaneous transfemoral coronary angioplasty was documented in five of five patients by visualizing the increase in vessel diameter at repeat investigation. CONCLUSION: Contrast-enhanced electron-beam CT yields promising results concerning the visualization of coronary artery stenoses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Self-citationNoninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT
Achenbach, S., Ulzheimer, S., Baum, U., Kachelrieß, M., Ropers, D., Giesler, T., Bautz, W., Daniel, W. G., Kalender, W. A., & Moshage, W. (2000) · Circulation · doi:10.1161/01.cir.102.23.2823 · Cited by 434
Self-citationPrognostic Value of Cardiac Computed Tomography Angiography
Hulten, E. A., Carbonaro, S., Petrillo, S. P., Mitchell, J. D., & Villines, T. C. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.10.011 · Cited by 412
Radiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CT
Hunold, P., Vogt, F. M., Schmermund, A., Debatin, J. F., Kerkhoff, G., Budde, T., Erbel, R., Ewen, K., & Barkhausen, J. (2003) · Radiology · doi:10.1148/radiol.2261011365 · Cited by 405
Achenbach, S., Moshage, W., Ropers, D., Nossen, J., & Daniel, W. G. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392702 · Cited by 382
Self-citationHou, Z.-H., Lu, B., Gao, Y., Jiang, S.-L., Wang, Y., Li, W., & Budoff, M. J. (2012) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2012.06.006 · Cited by 321
“to obtain noninvasive coronary angiograms in 1995 (4), cardiac CT has evolved to become a highly accurate method in the diagnosis of CAD, comparable to conventional invasive coronary angiography (5).”
MethodHong, C., Becker, C. R., Huber, A., Schoepf, U. J., Ohnesorge, B., Knez, A., Brüning, R., & Reiser, M. F. (2001) · Radiology · doi:10.1148/radiol.2203010055 · Cited by 255
ECG‐correlated image reconstruction from subsecond multi‐slice spiral CT scans of the heart
Kachelrieß, M., Ulzheimer, S., & Kalender, W. A. (2000) · Medical Physics · doi:10.1118/1.1286552 · Cited by 225
Noncardiac Findings in Cardiac Imaging With Multidetector Computed Tomography
Onuma, Y., Tanabe, K., Nakazawa, G., Aoki, J., Nakajima, H., Ibukuro, K., & Hara, K. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.04.071 · Cited by 215
Computed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Schmermund, A., Rensing, B. J., Sheedy, P. F., Bell, M. R., & Rumberger, J. A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00132-6 · Cited by 180
“Maximal intensity projections have been used to detect calcium (2), but they may not always permit reliable detection of stenoses because of the overlap of different structures in the planar projection format.”
BackgroundMethodResultInfluentialThematic review series: Patient-Oriented Research. Imaging atherosclerosis: state of the art
Crouse, J. R. (2006) · Journal of Lipid Research · doi:10.1194/jlr.r600012-jlr200 · Cited by 66
“(135) in 1995, and contrast-enhanced imaging of arterial lumens”
van Geuns, R.-J. M., Oudkerk, M., Rensing, B. J. W. M., Bongaerts, A. H. H., de Bruin, H. G., Wielopolski, P. A., van Ooijen, P., de Feyter, P. J., & Serruys, P. W. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02389-5 · Cited by 24
Metadata
- Authors
- Moshage, W. E., Achenbach, S., Seese, B., Bachmann, K., & Kirchgeorg, M.
- Venue
- Radiology
- Published
- 1995-09
- Volume
- 196
- Issue
- 3
- Pages
- 707-714
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2065989492
- Cited by
- 205
- References
- 0
- FWCI
- 11.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.