Digital tomosynthesis in breast imaging.
The DOI matches its Crossref record.
Abstract
PURPOSE: To describe and evaluate a method of tomosynthesis breast imaging with a full-field digital mammographic system. MATERIALS AND METHODS: In this tomosynthesis method, low-radiation-dose images were acquired as the x-ray source was moved in an arc above the stationary breast and digital detector. A step-and-expose method of imaging was used. Breast tomosynthesis and conventional images of two imaging phantoms and four mastectomy specimens were obtained. Three experienced readers scored the relative lesion visibility, lesion margin visibility, and confidence in the classification of six lesions. RESULTS: Tomosynthesis image-reconstruction algorithms allow tomographic imaging of the entire breast from a single arc of the x-ray source and at a radiation dose comparable with that in single-view mammography. Except for images of a large mass in a fatty breast, the tomosynthesis images were superior to the conventional images. CONCLUSION: Digital mammographic systems make breast tomosynthesis possible. Tomosynthesis may improve the specificity of mammography with improved lesion margin visibility and may improve early breast cancer detection, especially in women with radiographically dense breasts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Skaane, P., Bandos, A. I., Gullien, R., Eben, E. B., Ekseth, U., Haakenaasen, U., Izadi, M., Jebsen, I. N., Jahr, G., Krager, M., et al. (2013) · Radiology · doi:10.1148/radiol.12121373 · Cited by 1,012
Self-citationDedicated Breast CT: Radiation Dose and Image Quality Evaluation
Boone, J. M., Nelson, T. R., Lindfors, K. K., & Seibert, J. A. (2001) · Radiology · doi:10.1148/radiol.2213010334 · Cited by 468
Haas, B. M., Kalra, V., Geisel, J., Raghu, M., Durand, M., & Philpotts, L. E. (2013) · Radiology · doi:10.1148/radiol.13130307 · Cited by 419
Digital Breast Tomosynthesis: Observer Performance Study
Gur, D., Abrams, G. S., Chough, D. M., Ganott, M. A., Hakim, C. M., Perrin, R. L., Rathfon, G. Y., Sumkin, J. H., Zuley, M. L., & Bandos, A. I. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.2031 · Cited by 363
Dedicated Breast CT: Initial Clinical Experience
Lindfors, K. K., Boone, J. M., Nelson, T. R., Yang, K., Kwan, A. L. C., & Miller, D. F. (2008) · Radiology · doi:10.1148/radiol.2463070410 · Cited by 351
Andersson, I., Ikeda, D. M., Zackrisson, S., Ruschin, M., Svahn, T., Timberg, P., & Tingberg, A. (2008) · European Radiology · doi:10.1007/s00330-008-1076-9 · Cited by 343
Sechopoulos, I., Teuwen, J., & Mann, R. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.002 · Cited by 341
An outlook on x‐ray CT research and development
Wang, G., Yu, H., & De Man, B. (2008) · Medical Physics · doi:10.1118/1.2836950 · Cited by 341
Implementation of Breast Tomosynthesis in a Routine Screening Practice: An Observational Study
Rose, S. L., Tidwell, A. L., Bujnoch, L. J., Kushwaha, A. C., Nordmann, A. S., & Sexton, R. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9672 · Cited by 329
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Tomographic mammography using a limited number of low‐dose cone‐beam projection images
Wu, T., Stewart, A., Stanton, M., McCauley, T., Phillips, W., Kopans, D. B., Moore, R. H., Eberhard, J. W., Opsahl‐Ong, B., Niklason, L., et al. (2003) · Medical Physics · doi:10.1118/1.1543934 · Cited by 302
Self-citationSamala, R. K., Chan, H., Hadjiiski, L., Helvie, M. A., Wei, J., & Cha, K. (2016) · Medical Physics · doi:10.1118/1.4967345 · Cited by 289
A comparative study of limited‐angle cone‐beam reconstruction methods for breast tomosynthesis
Zhang, Y., Chan, H., Sahiner, B., Wei, J., Goodsitt, M. M., Hadjiiski, L. M., Ge, J., & Zhou, C. (2006) · Medical Physics · doi:10.1118/1.2237543 · Cited by 285
Contrast-enhanced Digital Mammography: Initial Clinical Experience
Jong, R. A., Yaffe, M. J., Skarpathiotakis, M., Shumak, R. S., Danjoux, N. M., Gunesekara, A., & Plewes, D. B. (2003) · Radiology · doi:10.1148/radiol.2283020961 · Cited by 278
Digital breast tomosynthesis versus digital mammography: a clinical performance study
Gennaro, G., Toledano, A., di Maggio, C., Baldan, E., Bezzon, E., La Grassa, M., Pescarini, L., Polico, I., Proietti, A., Toffoli, A., et al. (2010) · European Radiology · doi:10.1007/s00330-009-1699-5 · Cited by 257
Review of Terahertz Tomography Techniques
Guillet, J. P., Recur, B., Frederique, L., Bousquet, B., Canioni, L., Manek-Hönninger, I., Desbarats, P., & Mounaix, P. (2014) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-014-0057-0 · Cited by 254
Mammographic density. Measurement of mammographic density
Yaffe, M. J. (2008) · Breast Cancer Research · doi:10.1186/bcr2102 · Cited by 235
“Another possible source of volumetric data is tomosynthesis, a technique that uses projection images obtained at different angles about the breast (Figure 5) on a specialized digital mammography system to reconstruct quasi three-dimensional planar images, essentially of the X-ray attenuation coefficient of the breast…”
MethodBreast density implications and supplemental screening
Vourtsis, A., & Berg, W. A. (2019) · European Radiology · doi:10.1007/s00330-018-5668-8 · Cited by 217
Combined Optical and X-ray Tomosynthesis Breast Imaging
Fang, Q., Selb, J., Carp, S. A., Boverman, G., Miller, E. L., Brooks, D. H., Moore, R. H., Kopans, D. B., & Boas, D. A. (2011) · Radiology · doi:10.1148/radiol.10082176 · Cited by 207
Self-citationGilbert, F. J., Tucker, L., Gillan, M. G., Willsher, P., Cooke, J., Duncan, K. A., Michell, M. J., Dobson, H. M., Lim, Y. Y., Purushothaman, H., et al. (2015) · Health Technology Assessment · doi:10.3310/hta19040 · Cited by 195
Michell, M. J., Iqbal, A., Wasan, R. K., Evans, D. R., Peacock, C., Lawinski, C. P., Douiri, A., Wilson, R., & Whelehan, P. (2012) · Clinical Radiology · doi:10.1016/j.crad.2012.03.009 · Cited by 185
Conant, E. F., Beaber, E. F., Sprague, B. L., Herschorn, S. D., Weaver, D. L., Onega, T., Tosteson, A. N. A., McCarthy, A. M., Poplack, S. P., Haas, J. S., et al. (2016) · Breast Cancer Research and Treatment · doi:10.1007/s10549-016-3695-1 · Cited by 184
“The ability to scroll through the multiple reconstructed images minimizes the impact of overlapping structure which limits two-dimensional mammographic imaging [3].”
BackgroundSidky, E. Y., Pan, X., Reiser, I. S., Nishikawa, R. M., Moore, R. H., & Kopans, D. B. (2009) · Medical Physics · doi:10.1118/1.3232211 · Cited by 181
Self-citationChest tomosynthesis: Technical principles and clinical update
Dobbins, J. T., & McAdams, H. P. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.05.054 · Cited by 164
Clinical Digital Breast Tomosynthesis System: Dosimetric Characterization
Feng, S. S. J., & Sechopoulos, I. (2012) · Radiology · doi:10.1148/radiol.11111789 · Cited by 162
Digital Breast Tomosynthesis Is Comparable to Mammographic Spot Views for Mass Characterization
Noroozian, M., Hadjiiski, L., Rahnama-Moghadam, S., Klein, K. A., Jeffries, D. O., Pinsky, R. W., Chan, H.-P., Carson, P. L., Helvie, M. A., & Roubidoux, M. A. (2012) · Radiology · doi:10.1148/radiol.11101763 · Cited by 160
Dang, P. A., Freer, P. E., Humphrey, K. L., Halpern, E. F., & Rafferty, E. A. (2014) · Radiology · doi:10.1148/radiol.13130765 · Cited by 159
Evaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA
Gallas, B. D., Chan, H.-P., D’Orsi, C. J., Dodd, L. E., Giger, M. L., Gur, D., Krupinski, E. A., Metz, C. E., Myers, K. J., Obuchowski, N. A., et al. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.12.016 · Cited by 81
“One might say that the earlier work by Niklason et al (43) in 1997 on DBT occurred near the end of the exploratory phase.”
Metadata
- Authors
- Niklason, L. T., Christian, B. T., Niklason, L. E., Kopans, D. B., Castleberry, D. E., Opsahl-Ong, B. H., Landberg, C. E., Slanetz, P. J., Giardino, A. A., Moore, R., Albagli, D., DeJule, M. C., Fitzgerald, P. F., Fobare, D. F., Giambattista, B. W., Kwasnick, R. F., Liu, J., Lubowski, S. J., Possin, G. E., Richotte, J. F., Wei, C. Y., & Wirth, R. F.
- Venue
- Radiology
- Published
- 1997-11
- Volume
- 205
- Issue
- 2
- Pages
- 399-406
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2007930540
- Cited by
- 763
- References
- 0
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.