PURPOSE: To evaluate the clinical and biologic safety of ultrasmall superparamagnetic iron oxide particles (AMI-227) as a contrast agent for magnetic resonance (MR) lymphography and to assess their efficacy for the differentiation of metastatic and benign nodes in patients with urologic and pelvic cancer. MATERIALS AND METHODS: Thirty adults suspected of having lymph node metastases underwent MR imaging before and 22-26 hours after intravenous infusion of AMI-227 (1.7 mg Fe/kg). Sixty histopathologically proved lymph nodes were analyzed on MR images, and 29 of these nodes were also analyzed quantitatively. RESULTS: AMI-227 was well tolerated with no major side effects. It allowed the detection of 10 additional nodes relative to those detected at MR imaging without AMI-227. None of the 27 metastatic nodes showed a decrease in signal intensity (SI) on AMI-227-enhanced images; nine of 27 metastatic nodes showed an increase in SI on T1-weighted images, probably resulting from altered capillary permeability in the tumor. A visually perceptible reduction in SI, indicating active AMI-227 uptake, was observed on postcontrast T2- and T2*-weighted images in 16 of 21 benign nodes. The SI ratio of benign nodes was lower than that of metastatic nodes on T2- and T2*-weighted images. The sensitivity of AMI-227-enhanced MR lymphography was 100%, and the specificity was 80%. CONCLUSION: AMI-227 is safe and may facilitate the differentiation of metastatic and benign nodes in patients with urologic and pelvic cancers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Bipat, S., Glas, A. S., Slors, F. J. M., Zwinderman, A. H., Bossuyt, P. M. M., & Stoker, J. (2004) · Radiology · doi:10.1148/radiol.2323031368 · Cited by 1,015
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Clinical Translation of Nanomedicine
Min, Y., Caster, J. M., Eblan, M. J., & Wang, A. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00116 · Cited by 772
Krege, S., Beyer, J., Souchon, R., Albers, P., Albrecht, W., Algaba, F., Bamberg, M., Bodrogi, I., Bokemeyer, C., Cavallin-Ståhl, E., et al. (2008) · European Urology · doi:10.1016/j.eururo.2007.12.024 · Cited by 617
Imaging Prostate Cancer: A Multidisciplinary Perspective
Hricak, H., Choyke, P. L., Eberhardt, S. C., Leibel, S. A., & Scardino, P. T. (2007) · Radiology · doi:10.1148/radiol.2431030580 · Cited by 601
Schmoll, H. J., Souchon, R., Krege, S., Albers, P., Beyer, J., Kollmannsberger, C., Fossa, S. D., Skakkebaek, N. E., de Wit, R., Fizazi, K., et al. (2004) · Annals of Oncology · doi:10.1093/annonc/mdh301 · Cited by 510
Pelvic Lymph Node Dissection in Prostate Cancer
Briganti, A., Blute, M. L., Eastham, J. H., Graefen, M., Heidenreich, A., Karnes, J. R., Montorsi, F., & Studer, U. E. (2009) · European Urology · doi:10.1016/j.eururo.2009.03.012 · Cited by 501
Chemical Design of Biocompatible Iron Oxide Nanoparticles for Medical Applications
Ling, D., & Hyeon, T. (2013) · Small · doi:10.1002/smll.201202111 · Cited by 493
Rectal Cancer: Review with Emphasis on MR Imaging
Beets-Tan, R. G. H., & Beets, G. L. (2004) · Radiology · doi:10.1148/radiol.2322021326 · Cited by 381
High-Density Lipoproteins: Nature’s Multifunctional Nanoparticles
Kuai, R., Li, D., Chen, Y. E., Moon, J. J., & Schwendeman, A. (2016) · ACS Nano · doi:10.1021/acsnano.5b07522 · Cited by 338
Wang, A. Z., Bagalkot, V., Vasilliou, C. C., Gu, F., Alexis, F., Zhang, L., Shaikh, M., Yuet, K., Cima, M. J., Langer, R., et al. (2008) · ChemMedChem · doi:10.1002/cmdc.200800091 · Cited by 312
Heesakkers, R. A., Hövels, A. M., Jager, G. J., van den Bosch, H. C., Witjes, J. A., Raat, H. P., Severens, J. L., Adang, E. M., van der Kaa, C. H., Fütterer, J. J., et al. (2008) · The Lancet Oncology · doi:10.1016/s1470-2045(08)70203-1 · Cited by 307
Lahaye, M. J., Engelen, S. M. E., Nelemans, P. J., Beets, G. L., van de Velde, C. J. H., van Engelshoven, J. M. A., & Beets-Tan, R. G. H. (2005) · Seminars in Ultrasound, CT and MRI · doi:10.1053/j.sult.2005.04.005 · Cited by 307
Anzai, Y., Piccoli, C. W., Outwater, E. K., Stanford, W., Bluemke, D. A., Nurenberg, P., Saini, S., Maravilla, K. R., Feldman, D. E., Schmiedl, U. P., et al. (2003) · Radiology · doi:10.1148/radiol.2283020872 · Cited by 289
Diagnostic precision of nanoparticle-enhanced MRI for lymph-node metastases: a meta-analysis
Will, O., Purkayastha, S., Chan, C., Athanasiou, T., Darzi, A. W., Gedroyc, W., & Tekkis, P. P. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(05)70537-4 · Cited by 260
Urinary Bladder Cancer: Preoperative Nodal Staging with Ferumoxtran-10–enhanced MR Imaging
Deserno, W. M. L. L. G., Harisinghani, M. G., Taupitz, M., Jager, G. J., Witjes, J. A., Mulders, P. F., Hulsbergen van de Kaa, C. A., Kaufmann, D., & Barentsz, J. O. (2004) · Radiology · doi:10.1148/radiol.2332031111 · Cited by 212
(2004) · PubMed · Cited by 211
Kimura, K., Tanigawa, N., Matsuki, M., Nohara, T., Iwamoto, M., Sumiyoshi, K., Tanaka, S., Takahashi, Y., & Narumi, Y. (2010) · Breast Cancer · doi:10.1007/s12282-009-0143-7 · Cited by 41
“Recently, ultrasmall superparamagnetic iron oxide (USPIO) particles have been introduced as a contrast agent for intravenous MR lymphography [12, 13].”
Background
Metadata
- Authors
- Bellin, M. F., Roy, C., Kinkel, K., Thoumas, D., Zaim, S., Vanel, D., Tuchmann, C., Richard, F., Jacqmin, D., Delcourt, A., Challier, E., Lebret, T., & Cluzel, P.
- Venue
- Radiology
- Published
- 1998-06
- Volume
- 207
- Issue
- 3
- Pages
- 799-808
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2160165139
- Cited by
- 261
- References
- 0
- FWCI
- 10.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.