Renal Volume Measurements: Accuracy and Repeatability of US Compared with That of MR Imaging
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the accuracy and repeatability of ultrasonography (US) with the ellipsoid formula in calculating the renal volume. MATERIALS AND METHODS: The renal volumes in 20 volunteers aged 19-51 years were determined by using US with the ellipsoid formula and magnetic resonance (MR) imaging with the voxel-count method by two independent observers for each modality. The observers performed all measurements twice, with an interval between the first and second examinations. The voxel-count method was the reference standard. Repeatability was evaluated by calculating the SD of the difference (method of Bland and Altman). RESULTS: Renal volume was underestimated with US by 45 mL (25%) on average. A comparable underestimation was found when the ellipsoid formula was applied to MR images. This indicates that the inaccuracy of US renal volume measurements (a) occurred because the kidney does not resemble an ellipsoid and (b) was not primarily related to the imaging modality. Intra- and interobserver variations in US volume measurements were poor; the SD of the difference was 21-32 mL. For comparison, the SD of the difference in reference-standard measurements was 5-10 mL. CONCLUSION: Use of US with the ellipsoid formula is not appropriate for accurate and reproducible calculation of renal volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Kidney dimensions at sonography: correlation with age, sex, and habitus in 665 adult volunteers.
Emamian, S. A., Nielsen, M. B., Pedersen, J. F., & Ytte, L. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.160.1.8416654 · Cited by 454
Renovascular Hypertension: Anatomic and Renal Function Changes During Drug Therapy
Dean, R. H. (1981) · Archives of Surgery · doi:10.1001/archsurg.1981.01380230032005 · Cited by 291
Kohn, M. I., Tanna, N. K., Herman, G. T., Resnick, S. M., Mozley, P. D., Gur, R. E., Alavi, A., Zimmerman, R. A., & Gur, R. C. (1991) · Radiology · doi:10.1148/radiology.178.1.1984289 · Cited by 273
Jack, C. R., Bentley, M. D., Twomey, C. K., & Zinsmeister, A. R. (1990) · Radiology · doi:10.1148/radiology.176.1.2353093 · Cited by 197
Madaio, P. D. M. P. (1990) · Kidney International · doi:10.1038/ki.1990.236 · Cited by 186
Reliability of in vivo volume measures of hippocampus and other brain structures using MRI
Bartzokis, G., Mintz, J., Marx, P., Osborn, D., Gutkind, D., Chiang, F., Phelan, C., & Marder, S. R. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90218-3 · Cited by 114
In vitro evaluation of three-dimensional ultrasonography in volume estimation of abdominal organs
Gilja, O. H., Thune, N., Matre, K., Hausken, T., Ødegaard, S., & Berstad, A. (1994) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)90080-9 · Cited by 114
Emamian, S. A., Nielsen, M. B., & Pedersen, J. F. (1995) · Acta Radiologica · doi:10.1177/028418519503600414 · Cited by 112
Gilja, O. H., Smievoll, A. I., Thune, N., Matre, K., Hausken, T., Ødegaard, S., & Berstad, A. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00082-4 · Cited by 105
Evaluation of in vitro measurement accuracy of a three-dimensional ultrasound scanner.
King, D. L., King, D., & Shao, M. Y. (1991) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1991.10.2.77 · Cited by 102
In vitro measurement of kidney size: comparison of ultrasonography and MRI
Bakker, J., Olree, M., Kaatee, R. S. J. P., de Lange, E. E., & Beek, F. J. A. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00212-3 · Cited by 98
Self-citationComputerized Volume Measurement of Brain Structure
Ashtari, M., Zito, J. L., GOLD, B. I., Lieberman, J. A., Borenstein, M., & Herman, P. G. (1990) · Investigative Radiology · doi:10.1097/00004424-199007000-00009 · Cited by 86
Mitchell, J. R., Karlik, S. J., Lee, D. H., & Fenster, A. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040218 · Cited by 83
Reliability and exactness of MRI‐based volumetry: A phantom study
Luft, A. R., Skalej, M., Welte, D., Kolb, R., & Klose, U. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060421 · Cited by 72
How reliable are ultrasound measurements of renal length in adults?
Ablett, M. J., Coulthard, A., Lee, R. E. J., Richardson, D. L., Bellas, T., Owen, J. P., Keir, M. J., & Butler, T. J. (1995) · British Journal of Radiology · doi:10.1259/0007-1285-68-814-1087 · Cited by 64
Observer variability in the sonographic measurement of renal length in childhood
Sargent, M. A., & Wilson, B. P. M. (1992) · Clinical Radiology · doi:10.1016/s0009-9260(05)80382-4 · Cited by 42
Interobserver variation in the sonographic estimation of renal volume in children
Sargent, M. A., Long, G., Karmali, M., & Cheng, S. M. (1997) · Pediatric Radiology · doi:10.1007/s002470050207 · Cited by 29
Cited by
Applying the right statistics: analyses of measurement studies
Bland, J. M., & Altman, D. G. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.122 · Cited by 1,311
Irazabal, M. V., Rangel, L. J., Bergstralh, E. J., Osborn, S. L., Harmon, A. J., Sundsbak, J. L., Bae, K. T., Chapman, A. B., Grantham, J. J., Mrug, M., et al. (2015) · Journal of the American Society of Nephrology · doi:10.1681/asn.2013101138 · Cited by 625
Chapman, A. B., Devuyst, O., Eckardt, K.-U., Gansevoort, R. T., Harris, T., Horie, S., Kasiske, B. L., Odland, D., Pei, Y., Perrone, R. D., et al. (2015) · Kidney International · doi:10.1038/ki.2015.59 · Cited by 611
Normal Values for Renal Length and Volume as Measured by Magnetic Resonance Imaging
Cheong, B., Muthupillai, R., Rubin, M. F., & Flamm, S. D. (2007) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.00930306 · Cited by 265
Beland, M. D., Walle, N. L., Machan, J. T., & Cronan, J. J. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4104 · Cited by 170
“Estimates of volume can be made on the basis of the ellipsoid formula, but this method has an inherent defect because the kidney is not actually ellipsoid [5].”
Background
Metadata
- Authors
- Bakker, J., Olree, M., Kaatee, R., de Lange, E. E., Moons, K. G. M., Beutler, J. J., & Beek, F. J. A.
- Venue
- Radiology
- Published
- 1999-06
- Volume
- 211
- Issue
- 3
- Pages
- 623-628
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2150877210
- Cited by
- 248
- References
- 18
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.