The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Measurement of the Distribution Volume of Gadopentetate Dimeglumine at Echo-planar MR Imaging to Quantify Myocardial Infarction: Comparison with99mTc-DTPA Autoradiography in Rats
Abstract
PURPOSE: To measure the fractional distribution volume of gadopentetate dimeglumine in normal and reperfused infarcted myocardium at magnetic resonance (MR) imaging by using the fractional distribution volume of technetium 99m-diethylenetriaminepentaacetic acid (DTPA) as an independent reference. MATERIALS AND METHODS: Rats were subjected to 1 hour of coronary artery occlusion and 1 hour of reperfusion before inversion-recovery echo-planar imaging or autoradiography. Regional change in relaxation rate (delta R1) ratios for myocardium over blood were compared with radioactivity ratios for myocardium over blood after the injection of 99mTc-DTPA. RESULTS: Both delta R1 and radioactivity ratios demonstrated equilibrium distribution and hence represent partition coefficients (lambda). The fractional distribution volumes were greater in infarcted myocardium (0.90 +/- 0.05 for gadopentetate dimeglumine and 0.89 +/- 0.04 for 99mTc-DTPA) than in normal myocardium (0.23 +/- 0.02 for gadopentetate dimeglumine and 0.16 +/- 0.01 for 99mTc-DTPA). Area at risk at autoradiography was not significantly different from that at histomorphometry. The infarction size defined by using triphenyltetrazolium chloride was 13% +/- 4 smaller than that defined by using autoradiography. CONCLUSION: The fractional distribution volumes of gadopentetate dimeglumine and 99mTc-DTPA are similar and indicate extracellular distribution in normal myocardium and intracellular as well as extracellular distribution in reperfused infarction. Because the failure of cells to exclude these agents is indicative of necrosis, contrast medium-enhanced MR imaging may be useful to quantify myocardial infarction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent
Weinmann, H., Brasch, R., Press, W., & Wesbey, G. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.3.619 · Cited by 1,231
Kim, R. J., Chen, E.-L., Lima, J. A. C., & Judd, R. M. (1996) · Circulation · doi:10.1161/01.cir.94.12.3318 · Cited by 662
Lima, J. A. C., Judd, R. M., Bazille, A., Schulman, S. P., Atalar, E., & Zerhouni, E. A. (1995) · Circulation · doi:10.1161/01.cir.92.5.1117 · Cited by 474
Studies of Gd‐DTPA relaxivity and proton exchange rates in tissue
Donahue, K. M., Burstein, D., Manning, W. J., & Gray, M. L. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320110 · Cited by 339
Water diffusion and exchange as they influence contrast enhancement
Donahue, K. M., Weisskoff, R. M., & Burstein, D. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070114 · Cited by 270
Zhao, M., Zhang, H., Robinson, T. F., Factor, S. M., Sonnenblick, E. H., & Eng, C. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80137-7 · Cited by 242
Weissleder, R., Lee, A. S., Khaw, B. A., Shen, T., & Brady, T. J. (1992) · Radiology · doi:10.1148/radiology.182.2.1732953 · Cited by 186
Significance of subendocardial S-T segment elevation caused by coronary stenosis in the dog
Guyton, R. A., McClenathan, J. H., Newman, G. E., & Michaelis, L. L. (1977) · The American Journal of Cardiology · doi:10.1016/0002-9149(77)90159-x · Cited by 170
Saeed, M., Wendland, M. F., Masui, T., & Higgins, C. B. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310105 · Cited by 122
Self-citation
Cited by
Design and validation of Segment - freely available software for cardiovascular image analysis
Heiberg, E., Sjögren, J., Ugander, M., Carlsson, M., Engblom, H., & Arheden, H. (2010) · BMC Medical Imaging · doi:10.1186/1471-2342-10-1 · Cited by 929
Self-citationCardiac MRI Endpoints in Myocardial Infarction Experimental and Clinical Trials
Ibanez, B., Aletras, A. H., Arai, A. E., Arheden, H., Bax, J., Berry, C., Bucciarelli-Ducci, C., Croisille, P., Dall'Armellina, E., Dharmakumar, R., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.05.024 · Cited by 369
Self-citationSado, D. M., Flett, A. S., Banypersad, S. M., White, S. K., Maestrini, V., Quarta, G., Lachmann, R. H., Murphy, E., Mehta, A., Hughes, D. A., et al. (2012) · Heart · doi:10.1136/heartjnl-2012-302346 · Cited by 357
Roujol, S., Weingärtner, S., Foppa, M., Chow, K., Kawaji, K., Ngo, L. H., Kellman, P., Manning, W. J., Thompson, R. B., & Nezafat, R. (2014) · Radiology · doi:10.1148/radiol.14140296 · Cited by 317
Sickle cell anemia mice develop a unique cardiomyopathy with restrictive physiology
Bakeer, N., James, J., Roy, S., Wansapura, J., Shanmukhappa, S. K., Lorenz, J. N., Osinska, H., Backer, K., Huby, A.-C., Shrestha, A., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1600311113 · Cited by 79
Metadata
- Authors
- Arheden, H., Saeed, M., Higgins, C. B., Gao, D.-W., Bremerich, J., Wyttenbach, R., Dae, M. W., & Wendland, M. F.
- Venue
- Radiology
- Published
- 1999-06
- Volume
- 211
- Issue
- 3
- Pages
- 698-708
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2164111588
- Cited by
- 358
- References
- 17
- FWCI
- 6.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of the Distribution Volume of Gadopentetate Dimeglumine at Echo-planar MR Imaging to Quantify Myocardial Infarction: Comparison with99mTc-DTPA Autoradiography in Rats. https://app.cochat.ai/papers/10.1148/radiology.211.3.r99jn41698
- The paper
- Arheden, H., Saeed, M., Higgins, C. B., Gao, D.-W., Bremerich, J., Wyttenbach, R., Dae, M. W., & Wendland, M. F. (1999). Measurement of the Distribution Volume of Gadopentetate Dimeglumine at Echo-planar MR Imaging to Quantify Myocardial Infarction: Comparison with99mTc-DTPA Autoradiography in Rats. Radiology. https://doi.org/10.1148/radiology.211.3.r99jn41698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.