Computer-aided Diagnosis Applied to US of Solid Breast Nodules by Using Neural Networks
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: To increase the capabilities of ultrasonographic (US) technology for the differential diagnosis of solid breast tumors by using a neural network. MATERIALS AND METHODS: One hundred forty US images of solid breast nodules were evaluated. When a sonogram was obtained, an analog video signal from the VCR output of the scanner was transmitted to a notebook computer. A frame grabber connected to the printer port of the computer was then used to digitize the data. The suspicious tumor region on the digitized US image was manually selected. The texture information of the subimage was extracted, and a neural network classifier with autocorrelation features was used to classify the tumor as benign or malignant. In this experiment, 140 pathologically proved tumors (52 malignant and 88 benign tumors) were sampled with k-fold cross-validation (k = 10) to evaluate the performance with receiver operating characteristic curves. RESULTS: The accuracy of neural networks for classifying malignancies was 95.0% (133 of 140 tumors), the sensitivity was 98% (51 of 52), the specificity was 93% (82 of 88), the positive predictive value was 89% (51 of 57), and the negative predictive value was 99% (82 of 83). CONCLUSION: This system differentiated solid breast nodules with relatively high accuracy and helped inexperienced operators to avoid misdiagnoses. Because the neural network is trainable, it could be optimized if a larger set of tumor images is supplied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning representations by back-propagating errors
Rumelhart, D. E., Hinton, G. E., & Williams, R. J. (1986) · Nature · doi:10.1038/323533a0 · Cited by 31,892
Solid breast nodules: use of sonography to distinguish between benign and malignant lesions.
Stavros, A. T., Thickman, D., Rapp, C. L., Dennis, M. A., Parker, S. H., & Sisney, G. A. (1995) · Radiology · doi:10.1148/radiology.196.1.7784555 · Cited by 1,780
Pisani, P., Parkin, D. M., & Ferlay, J. (1993) · International Journal of Cancer · doi:10.1002/ijc.2910550604 · Cited by 583
Weiss, S. M., & Kapouleas, I. (1989) · International Joint Conference on Artificial Intelligence · Cited by 506
Back-propagation algorithm which varies the number of hidden units
Hirose, Y., Yamashita, K., & Hijiya, S. (1991) · Neural Networks · doi:10.1016/0893-6080(91)90032-z · Cited by 503
Sahiner, B., Chan, H.-P., Petrick, N., Wei, D., Helvie, M. A., Adler, D. D., & Goodsitt, M. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538937 · Cited by 420
Garra, B. (1993) · Ultrasonic Imaging · doi:10.1006/uimg.1993.1017 · Cited by 222
An adaptive density-weighted contrast enhancement filter for mammographic breast mass detection
Petrick, N., Chan, H.-P., Sahiner, B., & Wei, D. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.481441 · Cited by 201
Analysis of mammographic microcalcifications using gray-level image structure features
Dhawan, A. P., Chitre, Y. S., & Bonasso, C. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500063 · Cited by 186
Use of non-Rayleigh statistics for the identification of tumors in ultrasonic B-scans of the breast
Shankar, P. M., Reid, J. M., Ortega, H., Piccoli, C. W., & Goldberg, B. B. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251119 · Cited by 174
Zheng, B., Qian, W., & Clarke, L. P. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538936 · Cited by 97
Cited by
Assessment of tumor heterogeneity: an emerging imaging tool for clinical practice?
Davnall, F., Yip, C. S. P., Ljungqvist, G., Selmi, M., Ng, F., Sanghera, B., Ganeshan, B., Miles, K. A., Cook, G. J., & Goh, V. (2012) · Insights into Imaging · doi:10.1007/s13244-012-0196-6 · Cited by 878
Automated breast cancer detection and classification using ultrasound images: A survey
Cheng, H. D., Shan, J., Ju, W., Guo, Y., & Zhang, L. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2009.05.012 · Cited by 728
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Quantitative Ultrasound in Soft Tissues
(2013) · Springer eBooks · doi:10.1007/978-94-007-6952-6 · Cited by 302
Metadata
- Authors
- Chen, D.-R., Chang, R.-F., & Huang, Y.-L.
- Venue
- Radiology
- Published
- 1999-11
- Volume
- 213
- Issue
- 2
- Pages
- 407-412
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2154434563
- Cited by
- 183
- References
- 11
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.