Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare single- versus four-channel helical computed tomographic (CT) aortography. MATERIALS AND METHODS: Forty-eight patients with aortic aneurysm or dissection underwent four- and one-channel CT angiography. Scan pairs covered the thoracic inlet to the diaphragm (n = 10) and supraceliac abdominal aorta (n = 19) or thoracic inlet (n = 19) to the femoral arterial bifurcations. For four-channel CT, nominal section thickness and pitch were 2.5 mm and 6.0, respectively, and for one-channel CT, 3.0 mm and 2.0 to the infrarenal aorta and 5.0 mm and 2.0 to the femoral arteries. Effective section thickness, scanning duration, scanning coverage, dose of iodinated contrast material, and mean aortoiliac attenuation were compared. Data were summarized as speed (coverage/duration), scanning efficiency (speed/section thickness), and contrast efficiency (mean aortic attenuation/dose of contrast material). RESULTS: At four- versus one-channel CT, CT angiography was 2.6 times faster, scanning efficiency was 4.1 times greater, contrast efficiency was 2.5 times greater, dose of contrast material was reduced (mean, 57%; 97 vs 232 mL) without a significant change in aortic enhancement, and sections were thinner (mean, 40%; 3.2 vs 5.3 mm) despite a 59% shorter scanning duration (22 vs 56 seconds). CONCLUSION: Substantially reduced doses of contrast medium, shorter scanning durations, and narrower effective sections result with four- versus one-channel CT aortography. No advantages of one-channel CT aortography were demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional spiral CT angiography of the abdomen: initial clinical experience.
Rubin, G. D., Dake, M. D., Napel, S. A., McDonnell, C. H., & Jeffrey, R. B. (1993) · Radiology · doi:10.1148/radiology.186.1.8416556 · Cited by 362
Self-citationAortic Aneurysmal Disease: Assessment of Stent-Graft Treatment—CT versus Conventional Angiography
Armerding, M. D., Rubin, G. D., Beaulieu, C. F., et al. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap28138 · Cited by 176
Self-citationRubin, G. D., Walker, P. J., Dake, M. D., Napel, S., Jeffrey, R. B., McDonnell, C. H., Mitchell, R. S., & Miller, D. C. (1993) · Journal of Vascular Surgery · doi:10.1016/0741-5214(93)90075-w · Cited by 166
Self-citationCost Identification of Abdominal Aortic Aneurysm Imaging by Using Time and Motion Analyses
Rubin, G. D., Armerding, M. D., Dake, M. D., & Napel, S. A. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap4863 · Cited by 45
Self-citation
Cited by
Atherosclerotic Vascular Disease Conference: Writing Group III: Pathophysiology
Faxon, D. P., Fuster, V., Libby, P., Beckman, J. A., Hiatt, W. R., Thompson, R. W., Topper, J. N., Annex, B. H., Rundback, J. H., Fabunmi, R. P., et al. (2004) · Circulation · doi:10.1161/01.cir.0000128520.37674.ef · Cited by 414
Peripheral Artery Disease: Current Insight Into the Disease and Its Diagnosis and Management
Olin, J. W., & Sealove, B. A. (2010) · Mayo Clinic Proceedings · doi:10.4065/mcp.2010.0133 · Cited by 349
Multi–Detector Row CT Angiography of Lower Extremity Arterial Inflow and Runoff: Initial Experience
Rubin, G. D., Schmidt, A. J., Logan, L. J., & Sofilos, M. C. (2001) · Radiology · doi:10.1148/radiol.2211001325 · Cited by 302
Self-citationStavropoulos, S. W., & Charagundla, S. R. (2007) · Radiology · doi:10.1148/radiol.2433051649 · Cited by 243
Ota, H., Takase, K., Igarashi, K., Chiba, Y., Haga, K., Saito, H., & Takahashi, S. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.1.1820201 · Cited by 198
Metadata
- Authors
- Rubin, G. D., Shiau, M. C., Leung, A. N., Kee, S. T., Logan, L. J., & Sofilos, M. C.
- Venue
- Radiology
- Published
- 2000-06
- Volume
- 215
- Issue
- 3
- Pages
- 670-676
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1967246654
- Cited by
- 248
- References
- 4
- FWCI
- 23.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.