The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Normal Brain and Brain Tumor: Multicomponent Apparent Diffusion Coefficient Line Scan Imaging
Abstract
Magnetic resonance line scan diffusion imaging of the brain, with diffusion weighting between 5 and 5,000 sec/mm(2), was performed in healthy subjects and patients with a 1.5-T machine. For each voxel, biexponential signal decay fits produced two apparent diffusion constants and respective signal amplitudes. Images based on these parameters show potential for use in the differentiation of gray and white matter, edema, and tumor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast magnetic resonance diffusion-weighted imaging of acute human stroke
Warach, S., Chien, D., Li, W., Ronthal, M., & Edelman, R. R. (1992) · Neurology · doi:10.1212/wnl.42.9.1717 · Cited by 881
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
Cited by
MRI quantification of non-gaussian water diffusion by kurtosis analysis
Jensen, J. H., & Helpern, J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1518 · Cited by 1,251
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856
“The most basic (and popular) model used to analyze the apparent bi-exponential decay observed at high b values is the dual tensor model (Assaf and Cohen, 1998; Clark and Le Bihan, 2000; Maier et al., 2001; Niendorf et al., 1996; Ronen et al., 2003).”
BackgroundDiffusion MRI at 25: exploring brain tissue structure and function
Le Bihan, D., & Johansen-Berg, H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.006 · Cited by 498
Provenzale, J. M., Mukundan, S., & Barboriak, D. P. (2006) · Radiology · doi:10.1148/radiol.2393042031 · Cited by 402
Diffusion-weighted magnetic resonance imaging and its application to cancer
Charles-Edwards, E. M. (2006) · Cancer Imaging · doi:10.1102/1470-7330.2006.0021 · Cited by 350
Metadata
- Authors
- Maier, S. E., Bogner, P., Bajzik, G., Mamata, H., Mamata, Y., Repa, I., Jolesz, F. A., & Mulkern, R. V.
- Venue
- Radiology
- Published
- 2001-06
- Volume
- 219
- Issue
- 3
- Pages
- 842-849
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2072083906
- Cited by
- 158
- References
- 2
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Normal Brain and Brain Tumor: Multicomponent Apparent Diffusion Coefficient Line Scan Imaging. https://app.cochat.ai/papers/10.1148/radiology.219.3.r01jn02842
- The paper
- Maier, S. E., Bogner, P., Bajzik, G., Mamata, H., Mamata, Y., Repa, I., Jolesz, F. A., & Mulkern, R. V. (2001). Normal Brain and Brain Tumor: Multicomponent Apparent Diffusion Coefficient Line Scan Imaging. Radiology. https://doi.org/10.1148/radiology.219.3.r01jn02842
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.