In five healthy subjects and 18 patients, cine magnetic resonance (MR) imaging of the heart was performed with a true fast imaging with steady-state precession (FISP) sequence. Results were compared both quantitatively and qualitatively with those at cine fast low-angle shot (FLASH) MR imaging. The blood-myocardial contrast-to-noise ratio (CNR) was 2.0 times higher and the normalized (for measurement time and pixel size) blood-myocardial CNR was 4.0 times higher for true FISP compared with FLASH MR imaging. Qualitative scores for image quality were significantly higher with true FISP MR imaging. Segmented cine true FISP MR imaging generated high-contrast MR images of the heart in healthy subjects and in patients with heart disease and produced image quality superior to that with cine FLASH MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hanicke, W., & Merboldt, K.-D. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90433-6 · Cited by 826
Rapid NMR imaging of dynamic processes using the FLASII technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030217 · Cited by 381
Measuring signal-to-noise ratios in MR imaging.
Kaufman, L., Kramer, D. M., Crooks, L. E., & Ortendahl, D. A. (1989) · Radiology · doi:10.1148/radiology.173.1.2781018 · Cited by 360
Rapid Three-Dimensional MR Imaging Using the FLASH Technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198603000-00046 · Cited by 267
Segmented turboFLASH: method for breath-hold MR imaging of the liver with flexible contrast.
Edelman, R. R., Wallner, B., Singer, A., Atkinson, D. J., & Saini, S. (1990) · Radiology · doi:10.1148/radiology.177.2.2171014 · Cited by 142
0.3‐second flash mri of the human heart
Frahm, J., Merboldt, K. D., Bruhn, H., Gyngell, M. L., Hänicke, W., & Chien, D. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130114 · Cited by 93
Chien, D., Atkinson, D. J., & Edelman, R. R. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010108 · Cited by 72
Advances in cardiac applications of subsecond flash MRI
Chien, D., Merboldt, K., Hänicke, W., Bruhn, H., Gyngell, M. L., & Frahm, J. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90022-t · Cited by 33
Cited by
Recommendations for Noninvasive Evaluation of Native Valvular Regurgitation
Zoghbi, W. A., Adams, D., Bonow, R. O., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Hahn, R. T., Han, Y., Hung, J., Lang, R. M., et al. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.01.007 · Cited by 3,556
Maceira, A., Prasad, S., Khan, M., & Pennell, D. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600572889 · Cited by 847
Myocardial scarring in asymptomatic or mildly symptomatic patients with hypertrophic cardiomyopathy
Choudhury, L., Mahrholdt, H., Wagner, A., Choi, K. M., Elliott, M. D., Klocke, F. J., Bonow, R. O., Judd, R. M., & Kim, R. J. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02602-5 · Cited by 627
Bruder, O., Wagner, A., Jensen, C. J., Schneider, S., Ong, P., Kispert, E.-M., Nassenstein, K., Schlosser, T., Sabin, G. V., Sechtem, U., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.007 · Cited by 590
Geva, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-9 · Cited by 582
“085) [115].”
Maceira, A. M., Prasad, S. K., Khan, M., & Pennell, D. J. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl336 · Cited by 561
JCS/JSCS/JATS/JSVS 2020 Guidelines on the Management of Valvular Heart Disease
Izumi, C., Eishi, K., Ashihara, K., Arita, T., Otsuji, Y., Kunihara, T., Komiya, T., Shibata, T., Seo, Y., Daimon, M., et al. (2020) · Circulation Journal · doi:10.1253/circj.cj-20-0135 · Cited by 367
Whole-body MRI at high field: technical limits and clinical potential
Schick, F. (2005) · European Radiology · doi:10.1007/s00330-005-2678-0 · Cited by 314
Ibrahim, E.-S. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-36 · Cited by 274
Cardiac Index Is Associated With Brain Aging: The Framingham Heart Study
Jefferson, A. L., Himali, J. J., Beiser, A. S., Au, R., Massaro, J. M., Seshadri, S., Gona, P., Salton, C. J., DeCarli, C., O'Donnell, C. J., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.905091 · Cited by 256
Alfakih, K., Plein, S., Bloomer, T., Jones, T., Ridgway, J., & Sivananthan, M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10329 · Cited by 246
Inversion recovery TrueFISP: Quantification of T1, T2, and spin density
Schmitt, P., Griswold, M. A., Jakob, P. M., Kotas, M., Gulani, V., Flentje, M., & Haase, A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20058 · Cited by 242
Cardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“5 Tesla the balanced SSFP gradient echo sequence is used for most functional imaging applications and volumetric assessments due to the high intrinsic contrast it achieves between blood and myocardium throughout the cardiac cycle [30-33].”
Yamamuro, M., Tadamura, E., Kubo, S., Toyoda, H., Nishina, T., Ohba, M., Hosokawa, R., Kimura, T., Tamaki, N., Komeda, M., et al. (2005) · Radiology · doi:10.1148/radiol.2342031271 · Cited by 233
Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE
Feng, L., Srichai, M. B., Lim, R. P., Harrison, A., King, W., Adluru, G., Dibella, E. V. R., Sodickson, D. K., Otazo, R., & Kim, D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24440 · Cited by 232
“Breath-hold cine MRI with balanced steady– steady free precession readout, which is now considered the gold standard for imaging myocardial function, offers good spatial resolution, high blood-to-myocardium contrast, and exquisite image quality (8,9).”
Buechel, E. V., Kaiser, T., Jackson, C., Schmitz, A., & Kellenberger, C. J. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-19 · Cited by 228
Cardiovascular magnetic resonance physics for clinicians: part I
Ridgway, J. P. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-71 · Cited by 218
“5 Tesla the balanced SSFP gradient echo sequence is used for most functional imaging applications and volumetric assessments due to the high intrinsic contrast it achieves between blood and myocardium throughout the cardiac cycle [30-33].”
Cardiac MR Imaging: State of the Technology
Finn, J. P., Nael, K., Deshpande, V., Ratib, O., & Laub, G. (2006) · Radiology · doi:10.1148/radiol.2412041866 · Cited by 215
Self-citationMiller, S., Simonetti, O. P., Carr, J., Kramer, U., & Finn, J. P. (2002) · Radiology · doi:10.1148/radiol.2231010235 · Cited by 178
Self-citationBjørnerud, A., & Johansson, L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.904 · Cited by 173
“cardiac cine imaging has virtually disappeared with the introduction of true-FISP imaging.(105) With this noninvasive technique, the delineation between blood and myocardium is superior due to the inherent differences in relaxation properties between these tissues.”
MethodTadamura, E., Yamamuro, M., Kubo, S., Kanao, S., Saga, T., Harada, M., Ohba, M., Hosokawa, R., Kimura, T., Kita, T., et al. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.185.1.01850110 · Cited by 165
“Breathhold cine MRI was performed using segmented true fast imaging with steady-state precession [20, 21].”
MethodKoskenvuo, J. W., Karra, H., Lehtinen, J., Niemi, P., Pärkkä, J., Knuuti, J., & Hartiala, J. J. (2007) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00764.x · Cited by 28
Cardiac Magnetic Resonance Imaging for the Evaluation of Ventricular Function
Sarwar, A., Shapiro, M. D., Abbara, S., & Cury, R. C. (2008) · Seminars in Roentgenology · doi:10.1053/j.ro.2008.02.004 · Cited by 26
Magnetic resonance imaging in myocardial ischemia.
Viswamitra, S., Higgins, C. B., Meacham, D. F., & Mehta, J. L. (2004) · Current Opinion in Cardiology · doi:10.1097/01.hco.0000133112.66486.1d · Cited by 14
Metadata
- Authors
- Carr, J. C., Simonetti, O., Bundy, J., Li, D., Pereles, S., & Finn, J. P.
- Venue
- Radiology
- Published
- 2001-06
- Volume
- 219
- Issue
- 3
- Pages
- 828-834
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2154535327
- Cited by
- 468
- References
- 9
- FWCI
- 24.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.