CoChat

A Multichannel Deep Neural Network Model Analyzing Multiscale Functional Brain Connectome Data for Attention Deficit Hyperactivity Disorder Detection

Open access
Chen, Ming, Li, Hailong, Wang, Jinghua, Dillman, Jonathan R., Parikh, Nehal A., He, Lili · 2019 · Radiology: Artificial Intelligence
Cited by 50

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

PURPOSE: To develop a multichannel deep neural network (mcDNN) classification model based on multiscale brain functional connectome data and demonstrate the value of this model by using attention deficit hyperactivity disorder (ADHD) detection as an example. MATERIALS AND METHODS: In this retrospective case-control study, existing data from the Neuro Bureau ADHD-200 dataset consisting of 973 participants were used. Multiscale functional brain connectomes based on both anatomic and functional criteria were constructed. The mcDNN model used the multiscale brain connectome data and personal characteristic data (PCD) as joint features to detect ADHD and identify the most predictive brain connectome features for ADHD diagnosis. The mcDNN model was compared with single-channel deep neural network (scDNN) models and the classification performance was evaluated through cross-validation and hold-out validation with the metrics of accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). RESULTS: In the cross-validation, the mcDNN model using combined features (fusion of the multiscale brain connectome data and PCD) achieved the best performance in ADHD detection with an AUC of 0.82 (95% confidence interval [CI]: 0.80, 0.83) compared with scDNN models using the features of the brain connectome at each individual scale and PCD, independently. In the hold-out validation, the mcDNN model achieved an AUC of 0.74 (95% CI: 0.73, 0.76). CONCLUSION: An mcDNN model was developed for multiscale brain functional connectome data, and its utility for ADHD detection was demonstrated. By fusing the multiscale brain connectome data, the mcDNN model improved ADHD detection performance considerably over the use of a single scale.© RSNA, 2019.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/ryai.2019190012

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 50

Metadata

Authors
Chen, M., Li, H., Wang, J., Dillman, J. R., Parikh, N. A., & He, L.
Venue
Radiology: Artificial Intelligence
Published
2019-12-01
Volume
2
Issue
1
Pages
e190012
ISSN
2638-6100 (ISSN-L)
OpenAlex
W2994664327
Cited by
50
References
12
FWCI
3.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.