MRI Manufacturer Shift and Adaptation: Increasing the Generalizability of Deep Learning Segmentation for MR Images Acquired with Different Scanners
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Purpose To quantitatively evaluate the generalizability of a deep learning segmentation tool to MRI data from scanners of different MRI manufacturers and to improve the cross-manufacturer performance by using a manufacturer-adaptation strategy. Materials and Methods This retrospective study included 150 cine MRI datasets from three MRI manufacturers, acquired between 2017 and 2018 (n = 50 for manufacturer 1, manufacturer 2, and manufacturer 3). Three convolutional neural networks (CNNs) were trained to segment the left ventricle (LV), using datasets exclusively from images from a single manufacturer. A generative adversarial network (GAN) was trained to adapt the input image before segmentation. The LV segmentation performance, end-diastolic volume (EDV), end-systolic volume (ESV), LV mass, and LV ejection fraction (LVEF) were evaluated before and after manufacturer adaptation. Paired Wilcoxon signed rank tests were performed. Results The segmentation CNNs exhibited a significant performance drop when applied to datasets from different manufacturers (Dice reduced from 89.7% ± 2.3 [standard deviation] to 68.7% ± 10.8, P < .05, from 90.6% ± 2.1 to 59.5% ± 13.3, P < .05, from 89.2% ± 2.3 to 64.1% ± 12.0, P < .05, for manufacturer 1, 2, and 3, respectively). After manufacturer adaptation, the segmentation performance was significantly improved (from 68.7% ± 10.8 to 84.3% ± 6.2, P < .05, from 72.4% ± 10.2 to 85.7% ± 6.5, P < .05, for manufacturer 2 and 3, respectively). Quantitative LV function parameters were also significantly improved. For LVEF, the manufacturer adaptation increased the Pearson correlation from 0.005 to 0.89 for manufacturer 2 and from 0.77 to 0.94 for manufacturer 3. Conclusion A segmentation CNN well trained on datasets from one MRI manufacturer may not generalize well to datasets from other manufacturers. The proposed manufacturer adaptation can largely improve the generalizability of a deep learning segmentation tool without additional annotation. Supplemental material is available for this article. Keywords: Image Postprocessing, MR-Imaging, Segmentation © RSNA, 2020
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
A Style-Based Generator Architecture for Generative Adversarial Networks
Karras, T., Laine, S., & Aila, T. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00453 · Cited by 11,714
Deep learning in medical image analysis
Shen, D., Wu, G., & Suk, H.-I. (2017) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071516-044442 · Cited by 4,968
Bernard, O., Lalande, A., Zotti, C., Cervenansky, F., Yang, X., Heng, P.-A., Cetin, I., Lekadir, K., Camara, O., Gonzalez Ballester, M. A., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2837502 · Cited by 2,431 · cited 1×
“Deep learning methods have reported expert-level performance on many organsegmentation tasks (4,21,22).”
BackgroundBakas, S., Reyes, M., Jakab, A., Bauer, S., Rempfler, M., Crimi, A., Shinohara, R. T., Berger, C., Ha, S. M., Rozycki, M., et al. (2018) · Apollo - University of Cambridge Repository · doi:10.17863/cam.38755 · Cited by 1,441
Self-citationBakas, S., Reyes, M., Jakab, A., Bauer, S., Rempfler, M., Crimi, A., Shinohara, R. T., Berger, C., Ha, S. M., Rozycki, M., et al. (2018) · arXiv · doi:10.48550/arxiv.1811.02629 · Cited by 1,441 · cited 1×
“Deep learning methods have reported expert-level performance on many organsegmentation tasks (4,21,22).”
BackgroundSelf-citationSynthesizing Obama: learning lip sync from audio
Suwajanakorn, S., Seitz, S. M., & Kemelmacher-Shlizerman, I. (2017) · ACM Transactions on Graphics · doi:10.1145/3072959.3073640 · Cited by 1,057
Automated cardiovascular magnetic resonance image analysis with fully convolutional networks
Bai, W., Sinclair, M., Tarroni, G., Oktay, O., Rajchl, M., Vaillant, G., Lee, A. M., Aung, N., Lukaschuk, E., Sanghvi, M. M., et al. (2018) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-018-0471-x · Cited by 773 · cited 1×
“Multiple studies have demonstrated its excellent performance on the segmentation of cine MR images (4,15,19).”
BackgroundBluemke, D. A., Moy, L., Bredella, M. A., Ertl-Wagner, B. B., Fowler, K. J., Goh, V. J., Halpern, E. F., Hess, C. P., Schiebler, M. L., & Weiss, C. R. (2020) · Radiology · doi:10.1148/radiol.2019192515 · Cited by 343 · cited 1×
“The unsatisfactory generalization of CNNs across MRI data from different manufacturers has been reported previously (11) and noted in expert reviews (12,13).”
Background
Cited by
CLIP-Driven Universal Model for Organ Segmentation and Tumor Detection
Liu, J., Zhang, Y., Chen, J.-N., Xiao, J., Lu, Y., Landman, B. A., Yuan, Y., Yuille, A., Tang, Y., & Zhou, Z. (2023) · 2023 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51070.2023.01934 · Cited by 333
Guo, P., Wang, P., Zhou, J., Jiang, S., & Patel, V. M. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr46437.2021.00245 · Cited by 193
“At each institution, a local model is trained using its own data by iteratively minimizing the following loss Lrecon = ∑ (x,y)∼Dk ‖Gk(x)− y‖1, (2) Algorithm 1: FL-based MRI Reconstruction Input: D = {D1,D2, . . . ,DK}, datasets from K institution; P, the number of local epoches; Q, the number of global epoches; γ, lea…”
BackgroundEffects of MRI scanner manufacturers in classification tasks with deep learning models
Kushol, R., Parnianpour, P., Wilman, A. H., Kalra, S., & Yang, Y.-H. (2023) · Scientific Reports · doi:10.1038/s41598-023-43715-5 · Cited by 54
de Almeida, J. G., Messiou, C., Withey, S. J., Matos, C., Koh, D.-M., & Papanikolaou, N. (2025) · European Radiology · doi:10.1007/s00330-025-11654-6 · Cited by 23
“This is crucial as changes to protocol and scanner manufacturer [14, 36 – 39] can affect performance.”
Metadata
- Authors
- Yan, W., Huang, L., Xia, L., Gu, S., Yan, F., Wang, Y., & Tao, Q.
- Venue
- Radiology: Artificial Intelligence
- Published
- 2020-07-01
- Volume
- 2
- Issue
- 4
- Pages
- e190195
- ISSN
- 2638-6100 (ISSN-L)
- OpenAlex
- W3040079328
- Cited by
- 66
- References
- 10
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.