CoChat

Automated Quantification of CT Patterns Associated with COVID-19 from Chest CT

Open access
Chaganti, Shikha, Grenier, Philippe, Balachandran, Abishek, Chabin, Guillaume, Cohen, Stuart, Flohr, Thomas, Georgescu, Bogdan, Grbic, Sasa, Liu, Siqi, Mellot, François, Murray, Nicolas, Nicolaou, Savvas, Parker, William, Re, Thomas, Sanelli, Pina, Sauter, Alexander W., Xu, Zhoubing, Yoo, Youngjin, Ziebandt, Valentin, Comaniciu, Dorin · 2020 · Radiology: Artificial Intelligence
Cited by 147

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Purpose To present a method that automatically segments and quantifies abnormal CT patterns commonly present in COVID-19, namely ground-glass opacities and consolidations. Materials and Methods In this retrospective study, the proposed method takes as input a noncontrast chest CT and segments the lesions, lungs, and lobes in three dimensions, based on a dataset of 9749 chest CT volumes. The method outputs two combined measures of the severity of lung and lobe involvement, quantifying both the extent of COVID-19 abnormalities and presence of high opacities, based on deep learning and deep reinforcement learning. The first measure of (percentage of opacity, percentage of high opacity [PO, PHO]) is global, while the second of (lung severity score, lung high opacity score [LSS, LHOS]) is lobe-wise. Evaluation of the algorithm is reported on CT studies of 200 participants (100 COVID-19 confirmed patients and 100 healthy controls) from institutions from Canada, Europe, and the United States collected between 2002 and April 2020. Ground truth is established by manual annotations of lesions, lungs, and lobes. Correlation and regression analyses were performed to compare the prediction to the ground truth. Results Pearson correlation coefficient between method prediction and ground truth for COVID-19 cases was calculated as 0.92 for PO (P < .001), 0.97 for PHO (P < .001), 0.91 for LSS (P < .001), and 0.90 for LHOS (P < .001). Ninety-eight of 100 healthy controls had a predicted PO of less than 1%; two had between 1% and 2%. Automated processing time to compute the severity scores was 10 seconds per case compared with 30 minutes required for manual annotations. Conclusion A new method segments regions of CT abnormalities associated with COVID-19 and computes (PO, PHO), as well as (LSS, LHOS) severity scores. Keywords: CT, Lung, Segmentation/Vision/Application Domain, Quantification/Vision/Application Domain, Supervised Learning, Reinforcement Learning © RSNA, 2021 Supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/ryai.2020200048

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Chaganti, S., Grenier, P., Balachandran, A., Chabin, G., Cohen, S., Flohr, T., Georgescu, B., Grbic, S., Liu, S., Mellot, F., Murray, N., Nicolaou, S., Parker, W., Re, T., Sanelli, P., Sauter, A. W., Xu, Z., Yoo, Y., Ziebandt, V., & Comaniciu, D.
Venue
Radiology: Artificial Intelligence
Published
2020-07-01
Volume
2
Issue
4
Pages
e200048
ISSN
2638-6100 (ISSN-L)
OpenAlex
W3035151116
Cited by
147
References
7
FWCI
14.23
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.