CoChat

Combining Initial Radiographs and Clinical Variables Improves Deep Learning Prognostication in Patients with COVID-19 from the Emergency Department

Open access
Kwon, Young Joon (Fred), Toussie, Danielle, Finkelstein, Mark, Cedillo, Mario A., Maron, Samuel Z., Manna, Sayan, Voutsinas, Nicholas, Eber, Corey, Jacobi, Adam, Bernheim, Adam, Gupta, Yogesh Sean, Chung, Michael S., Fayad, Zahi A., Glicksberg, Benjamin S., Oermann, Eric K., Costa, Anthony B. · 2021 · Radiology: Artificial Intelligence
Cited by 53

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Purpose To train a deep learning classification algorithm to predict chest radiograph severity scores and clinical outcomes in patients with coronavirus disease 2019 (COVID-19). Materials and Methods In this retrospective cohort study, patients aged 21–50 years who presented to the emergency department (ED) of a multicenter urban health system from March 10 to 26, 2020, with COVID-19 confirmation at real-time reverse-transcription polymerase chain reaction screening were identified. The initial chest radiographs, clinical variables, and outcomes, including admission, intubation, and survival, were collected within 30 days (n = 338; median age, 39 years; 210 men). Two fellowship-trained cardiothoracic radiologists examined chest radiographs for opacities and assigned a clinically validated severity score. A deep learning algorithm was trained to predict outcomes on a holdout test set composed of patients with confirmed COVID-19 who presented between March 27 and 29, 2020 (n = 161; median age, 60 years; 98 men) for both younger (age range, 21–50 years; n = 51) and older (age >50 years, n = 110) populations. Bootstrapping was used to compute CIs. Results The model trained on the chest radiograph severity score produced the following areas under the receiver operating characteristic curves (AUCs): 0.80 (95% CI: 0.73, 0.88) for the chest radiograph severity score, 0.76 (95% CI: 0.68, 0.84) for admission, 0.66 (95% CI: 0.56, 0.75) for intubation, and 0.59 (95% CI: 0.49, 0.69) for death. The model trained on clinical variables produced an AUC of 0.64 (95% CI: 0.55, 0.73) for intubation and an AUC of 0.59 (95% CI: 0.50, 0.68) for death. Combining chest radiography and clinical variables increased the AUC of intubation and death to 0.88 (95% CI: 0.79, 0.96) and 0.82 (95% CI: 0.72, 0.91), respectively. Conclusion The combination of imaging and clinical information improves outcome predictions. Supplemental material is available for this article. Keywords: Adults, Conventional Radiography, Infection, Lung, Pleura, Prognosis, Thorax © RSNA, 2020

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/ryai.2020200098

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 53

Metadata

Authors
Kwon, Y. J. (., Toussie, D., Finkelstein, M., Cedillo, M. A., Maron, S. Z., Manna, S., Voutsinas, N., Eber, C., Jacobi, A., Bernheim, A., Gupta, Y. S., Chung, M. S., Fayad, Z. A., Glicksberg, B. S., Oermann, E. K., & Costa, A. B.
Venue
Radiology: Artificial Intelligence
Published
2021-03-01
Volume
3
Issue
2
Pages
e200098
ISSN
2638-6100 (ISSN-L)
OpenAlex
W3112660304
Cited by
53
References
11
FWCI
4.71
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.