Abstract
We report on the preparation and properties of "blue" sputtered iridium oxide films (blue SIROF) and compare their properties with those of previous "black" SIROF's as well as anodically grown iridium oxide films (AIROF's). Blue SIROF's are prepared by reactive d‐c sputtering of iridium in argon/oxygen, mixture, at deposition rates of about 200 Å/min onto substrates held at 238 K. The physical properties of blue SIROF show characteristics similar to AIROF's. In contrast to SIROF's previously deposited in pure oxygen onto substrates held at 289 K, the new films have an optical absorption spectrum which peaks at 610 nm. The cyclic voltammograms, the magnitude of the electronic conductivity change, and their density are closer to those of AIROF's than previous SIROF's. As electrochromic display electrodes, the blue SIROF's have an improved open‐circuit bleached state and written‐state memory, as well as an improved appearance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yamanaka, K. (1989) · Japanese Journal of Applied Physics · doi:10.1143/jjap.28.632 · Cited by 280
Electrodeposited iridium oxide for neural stimulation and recording electrodes
Meyer, R. D., Cogan, S. F., Nguyen, T. H., & Rauh, R. D. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918271 · Cited by 255
“have not been extensively evaluated except as electrochromic coatings [16] and pH sensing electrodes [17].”
BackgroundAnodic deposition of a robust iridium-based water-oxidation catalyst from organometallic precursors
Blakemore, J. D., Schley, N. D., Olack, G. W., Incarvito, C. D., Brudvig, G. W., & Crabtree, R. H. (2011) · Chem. Sci. · doi:10.1039/c0sc00418a · Cited by 225
Negi, S., Bhandari, R., Rieth, L., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 201
Sputtered iridium oxide films for neural stimulation electrodes
Cogan, S. F., Ehrlich, J., Plante, T. D., Smirnov, A., Shire, D. B., Gingerich, M., & Rizzo, J. F. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31223 · Cited by 188
Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1747881 · Cited by 154
Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138
Mailley, S. C., Hyland, M., Mailley, P., McLaughlin, J. M., & McAdams, E. T. (2002) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(02)00098-x · Cited by 84
Metadata
- Authors
- Kang, K. S., & Shay, J. L.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 1983-04-01
- Volume
- 130
- Issue
- 4
- Pages
- 766-769
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2047681619
- Cited by
- 58
- References
- 0
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.