Oxidation State Changes and Structure of Electrochromic Iridium Oxide Films
Open accessThe DOI matches its Crossref record.
Abstract
Oxidation state changes, completeness of oxidation, and densities of anodically formed, electrochromic iridium oxide films have been determined by combined gravimetric, coulometric, and reflection spectroscopy analyses. The results show that the oxidation state of Ir ions in the oxide is changed from III to IV during the anodic coloration process [0.25 to 1.25V (RHE)], rather than II to IV as previously postulated, and that virtually all Ir ions in the film are accessible for electrochemical oxidation and reduction. The mean density of the oxide film is 2.0g cm −3 , as compared to 11.68 for bulk crystalline . The structure of the film was shown by electron microscopy to consist of oxide grains 0.05–0.1 μm in diameter, surrounded by voids. In addition, the presence of a high density of microvoids ∼25Å in diameter was detected. The highly porous structure of the film permits ready access of the electrolyte to the oxide grains throughout the entire film and facilitates the rapid coloration and bleaching (∼40 msec) observed in aqueous electrolytes. The apparent accessibility of all Ir ions in the film also implies rapid transport, within the oxide grains, of the mobile charge‐compensating ions which must be injected and ejected to preserve electroneutrality. Mechanisms of ion and electron transport are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oxygen electrocatalysts for water electrolyzers and reversible fuel cells: status and perspective
Park, S., Shao, Y., Liu, J., & Wang, Y. (2012) · Energy & Environmental Science · doi:10.1039/c2ee22554a · Cited by 578
Electrochromic materials and devices for energy efficient windows
Lampert, C. M. (1984) · Solar Energy Materials · doi:10.1016/0165-1633(84)90024-8 · Cited by 575
Electrodeposited iridium oxide for neural stimulation and recording electrodes
Meyer, R. D., Cogan, S. F., Nguyen, T. H., & Rauh, R. D. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918271 · Cited by 255
“AIROF has density of 2 g/cm [ 32 ], which is only 20% of the bulk density of the oxide, and the density of EIROF is presumably of this order.”
BackgroundOver-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210
Negi, S., Bhandari, R., Rieth, L., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 201
A voltammetric investigation of the charge storage reactions of hydrous iridium oxide layers
Burke, L. D., & Whelan, D. P. (1984) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(84)80159-x · Cited by 198
Transition metal oxide electrochromic materials and displays: a review
Dautremont-Smith, W. C. (1982) · Displays · doi:10.1016/0141-9382(82)90061-0 · Cited by 195
Sputtered iridium oxide films for neural stimulation electrodes
Cogan, S. F., Ehrlich, J., Plante, T. D., Smirnov, A., Shire, D. B., Gingerich, M., & Rizzo, J. F. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31223 · Cited by 188
Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138
Metadata
- Authors
- McIntyre, J. D. E., Peck, W. F., & Nakahara, S.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 1980-06-01
- Volume
- 127
- Issue
- 6
- Pages
- 1264-1268
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W1967852799
- Cited by
- 103
- References
- 0
- FWCI
- 11.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.