The DOI matches its Crossref record.
The Electrodeposition of Aluminum from Nonaqueous Solutions at Room Temperature
Open accessAbstract
The electrodeposition of aluminum in the form of white or shiny adherent plates on various metals has been accomplished at room temperature. A satisfactory plating solution is prepared by mixing two moles of anhydrous aluminum chloride with 1 mole of ethyl pyridinium bromide, preferably in a dry, oxygen‐free atmosphere, to produce a liquid to which benzene (or toluene) is added until a second layer, principally excess benzene, forms on the top of the plating solution. Using an aluminum anode, plating may be carried out in a protected atmosphere at cathode current densities of approximately 1 amp/dm 2 (about 9 amp/ft 2 ) using voltages of the order of one volt. The use of an alternating current superimposed on the direct plating current ( a ) greatly improved adherence, e.g., a copper wire plated by this procedure can be repeatedly flexed without breaking the coating; ( b ) increased thickness without brittleness; ( c ) increased maximum current density; ( d ) somewhat lowered the voltage requirement; ( e ) gave the same efficiency based on the direct current; and ( f ) changed the appearance from shiny to satiny.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deep Eutectic Solvents (DESs) and Their Applications
Smith, E. L., Abbott, A. P., & Ryder, K. S. (2014) · Chemical Reviews · doi:10.1021/cr300162p · Cited by 7,378
Ionic Liquids—New “Solutions” for Transition Metal Catalysis
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001103)39:21<3772::aid-anie3772>3.0.co;2-5 · Cited by 5,720
Applications of ionic liquids in the chemical industry
Plechkova, N. V., & Seddon, K. R. (2008) · Chem. Soc. Rev. · doi:10.1039/b006677j · Cited by 5,686
A short history of ionic liquids—from molten salts to neoteric solvents
Wilkes, J. S. (2002) · Green Chemistry · doi:10.1039/b110838g · Cited by 1,684
Understanding Ionic Liquids at the Molecular Level: Facts, Problems, and Controversies
Weingärtner, H. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200604951 · Cited by 1,543
Ionic Liquids at Electrified Interfaces
Fedorov, M. V., & Kornyshev, A. A. (2014) · Chemical Reviews · doi:10.1021/cr400374x · Cited by 1,398
Room temperature ionic liquids and their mixtures—a review
Marsh, K. N., Boxall, J. A., & Lichtenthaler, R. (2004) · Fluid Phase Equilibria · doi:10.1016/j.fluid.2004.02.003 · Cited by 1,306
Air and water stable ionic liquids in physical chemistry
Endres, F., & Zein El Abedin, S. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b600519p · Cited by 1,134
New developments in catalysis using ionic liquids
Gordon, C. M. (2001) · Applied Catalysis A: General · doi:10.1016/s0926-860x(01)00834-1 · Cited by 1,004
Ionic Liquids-Based Extraction: A Promising Strategy for the Advanced Nuclear Fuel Cycle
Sun, X., Luo, H., & Dai, S. (2012) · Chemical Reviews · doi:10.1021/cr200193x · Cited by 852
Application of ionic liquids to the electrodeposition of metals
Abbott, A. P., & McKenzie, K. J. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b607329h · Cited by 817
Preparation of Inorganic Materials Using Ionic Liquids
Ma, Z., Yu, J., & Dai, S. (2010) · Advanced Materials · doi:10.1002/adma.200900603 · Cited by 777
Chemical and biochemical transformations in ionic liquids
Jain, N., Kumar, A., Chauhan, S., & Chauhan, S. M. S. (2005) · Tetrahedron · doi:10.1016/j.tet.2004.10.070 · Cited by 726
Are Ionic Liquids Chemically Stable?
Wang, B., Qin, L., Mu, T., Xue, Z., & Gao, G. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00594 · Cited by 665
Ionische Flüssigkeiten – neue „Lösungen“ für die Übergangsmetallkatalyse
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3757(20001103)112:21<3926::aid-ange3926>3.0.co;2-u · Cited by 650
Microstructural and Dynamical Heterogeneities in Ionic Liquids
Wang, Y.-L., Li, B., Sarman, S., Mocci, F., Lu, Z.-Y., Yuan, J., Laaksonen, A., & Fayer, M. D. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00693 · Cited by 465
Advances on biomass pretreatment using ionic liquids: An overview
Tadesse, H., & Luque, R. (2011) · Energy & Environmental Science · doi:10.1039/c0ee00667j · Cited by 434
Application of ionic liquids in electrochemical sensing systems
Shiddiky, M. J. A., & Torriero, A. A. J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.064 · Cited by 408
Processing of metals and metal oxides using ionic liquids
Abbott, A. P., Frisch, G., Hartley, J., & Ryder, K. S. (2011) · Green Chemistry · doi:10.1039/c0gc00716a · Cited by 404
Ionic Liquids as Active Pharmaceutical Ingredients
Ferraz, R., Branco, L. C., Prudêncio, C., Noronha, J. P., & Petrovski, Ž. (2011) · ChemMedChem · doi:10.1002/cmdc.201100082 · Cited by 379
Progress and prospects of next-generation redox flow batteries
Zhang, C., Zhang, L., Ding, Y., Peng, S., Guo, X., Zhao, Y., He, G., & Yu, G. (2018) · Energy Storage Materials · doi:10.1016/j.ensm.2018.06.008 · Cited by 336
Ionic liquids confined in porous matrices: Physicochemical properties and applications
Singh, M. P., Singh, R. K., & Chandra, S. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2014.03.001 · Cited by 318
Halometallate ionic liquids – revisited
Estager, J., Holbrey, J. D., & Swadźba-Kwaśny, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60310e · Cited by 308
Metal-containing ionic liquids and ionic liquid crystals based on imidazolium moiety
Lin, I. J. B., & Vasam, C. S. (2005) · Journal of Organometallic Chemistry · doi:10.1016/j.jorganchem.2005.03.007 · Cited by 292
Ionic Liquids in Chemical Analysis
Koel, M. (2005) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340500304016 · Cited by 290
An overview and prospective on Al and Al-ion battery technologies
Elia, G. A., Kravchyk, K. V., Kovalenko, M. V., Chacón, J., Holland, A., & Wills, R. G. A. (2021) · Journal of Power Sources · doi:10.1016/j.jpowsour.2020.228870 · Cited by 263
Application of ionic liquids for liquid–liquid microextraction
Zhang, P., Hu, L., Lu, R., Zhou, W., & Gao, H. (2013) · Analytical Methods · doi:10.1039/c3ay40597d · Cited by 50
Metadata
- Authors
- Hurley, F. H., & WIer, T. P.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 1951
- Volume
- 98
- Issue
- 5
- Pages
- 207
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W1972945634
- Cited by
- 277
- References
- 0
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.