The DOI matches its Crossref record; 217 of the 217 references it cites were found in a registry or an index.
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Open accessAbstract
Exhaled human breath analysis is a very promising field of research work having great potential for diagnosis of diseases in non-invasive way. Breath analysis has attracted huge attention in the field of medical diagnosis and disease monitoring in the last two decades. VOCs/gases (Volatile Organic Compounds) in exhaled breath bear the finger-prints of metabolic and biophysical processes going on in human body. It’s a non-invasive, fast, non-hazardous, cost effective, and point of care process for disease state monitoring and environmental exposure assessment in human beings. Some VOCs/gases in exhaled breath are bio-markers of different diseases and their presence in excess amount is indicative of un-healthiness. Breath analysis has the potential for early detection of diseases. However, it is still underused and commercial device is yet not available owing to multiferrious challenges. This review is intended to provide an overview of major biomarkers (VOCs/gases) present in exhaled breath, importance of their analysis towards disease monitoring, analytical techniques involved, promising materials for breath analysis etc. Finally, related challenges and limitations along with future scope will be touched upon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–217 of 217
H2S sensing characteristics of La0.7Pb0.3Fe0.4Ni0.6O3 based nanocrystalline thick film gas sensor
Jagtap, S., Kadu, A. V., -, V. S. S., Manorama, S. V., & Chaudhari, G. N. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.11.021 · Cited by 29
Promotion on Acetone Sensing of Single SnO2 Nanobelt by Eu Doping
Chen, W., Qin, Z., Liu, Y., Zhang, Y., Li, Y., Shen, S., Wang, Z. M., & Song, H. (2017) · Nanoscale Research Letters · doi:10.1186/s11671-017-2177-7 · Cited by 29
Nanostructure Modified Gas Sensor Detection Matrix for NO Transient Conversion of NO to NO2
Özdemir, S., Osburn, T. B., & Gole, J. L. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3583368 · Cited by 28
Bhattacharyya, D., Smith, Y. R., Mohanty, S. K., & Misra, M. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0221606jes · Cited by 26
Breathomics as a diagnostic tool for pulmonary embolism
Fens, N., Douma, R. A., Sterk, P. J., & Kamphuisen, P. W. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04064.x · Cited by 25
7.1.3 Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Pratsinis, S. E., Schmid, A., & Amann, A. (2012) · Proceedings IMCS 2012 · doi:10.5162/imcs2012/7.1.3 · Cited by 24
Smith, Y. R., Bhattacharyya, D., Mohanty, S. K., & Misra, M. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0741603jes · Cited by 22
Breath profiles by electronic nose correlate with systemic markers but not ozone response
Biller, H., Holz, O., Windt, H., Koch, W., Müller, M., Jörres, R. A., Krug, N., & Hohlfeld, J. M. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.03.002 · Cited by 21
Room Temperature Detection of Acetone by a PANI/Cellulose/WO3Electrochemical Sensor
Aparicio-Martínez, E. P., Osuna, V., Dominguez, R. B., Márquez‐Lucero, A., Zaragoza‐Contreras, E. A., & Vega‐Ríos, A. (2018) · Journal of Nanomaterials · doi:10.1155/2018/6519694 · Cited by 20
Current Status of Clinical Breath Analysis
Risby, T. H. (2006) · doi:10.1364/lacsea.2006.tud1 · Cited by 20
Diagnosis of kidney failure by analysis of the concentration of ammonia in exhaled human breath
Essiet, I. O. (2013) · Journal of Emerging Trends in Engineering and Applied Sciences · Cited by 19
Xing, X., Chen, N., Yang, Y., Zhao, R., Wang, Z., Wang, Z., Zou, T., & Wang, Y. D. (2018) · physica status solidi (a) · doi:10.1002/pssa.201800100 · Cited by 19
Chung, Y., Park, H., Lee, E., Kim, S., & Kim, D. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0751613jes · Cited by 17
The characteristics of novel low-cost sensors for volatile biomarker detection
Costello, B. D. L., Ewen, R. J., Ratcliffe, N. M., & Richards, M. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037017 · Cited by 15
Jalal, A. H., Umasankar, Y., Christopher, F., Pretto, E. A., & Bhansali, S. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0111808jes · Cited by 15
Improved acetone sensing properties of electrospun Au-doped SnO2 nanofibers
Priya, M. J., Aswathy, P. M., Kavitha, M. K., Jayaraj, M. K., & Kumar, K. R. (2019) · AIP conference proceedings · doi:10.1063/1.5093844 · Cited by 9
Spray deposited gallium doped tin oxide thinfilm for acetone sensor application
Preethi, M. S., Bharath, S. P., & Bangera, K. V. (2018) · AIP conference proceedings · doi:10.1063/1.5029664 · Cited by 1
Cited by
Recent Progress on Flexible Room-Temperature Gas Sensors Based on Metal Oxide Semiconductor
Ou, L.-X., Liu, M.-Y., Zhu, L.-Y., Zhang, D. W., & Lu, H.-L. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00956-9 · Cited by 402
Electrospinning and Nanofiber Technology: Fundamentals, Innovations, and Applications
Cho, Y., Baek, J. W., Sagong, M., Ahn, S., Nam, J. S., & Kim, I. (2025) · Advanced Materials · doi:10.1002/adma.202500162 · Cited by 334
Chemiresistive Sensor Arrays for Gas/Volatile Organic Compounds Monitoring: A Review
Rath, R. J., Farajikhah, S., Oveissi, F., Dehghani, F., & Naficy, S. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202200830 · Cited by 183
Breath VOC analysis and machine learning approaches for disease screening: a review
P, H., Rangarajan, M., & Pandya, H. J. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/acb283 · Cited by 37
Binson, V. A., & Subramoniam, M. (2022) · Journal of Biomimetics, Biomaterials and Biomedical Engineering · doi:10.4028/p-dab04j · Cited by 14
Metadata
- Authors
- Das, S., & Pal, M.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2020-01-02
- Volume
- 167
- Issue
- 3
- Pages
- 037562
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W3004911392
- Cited by
- 466
- References
- 217
- FWCI
- 17.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).