Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Open accessAbstract
Exhaled human breath analysis is a very promising field of research work having great potential for diagnosis of diseases in non-invasive way. Breath analysis has attracted huge attention in the field of medical diagnosis and disease monitoring in the last two decades. VOCs/gases (Volatile Organic Compounds) in exhaled breath bear the finger-prints of metabolic and biophysical processes going on in human body. It’s a non-invasive, fast, non-hazardous, cost effective, and point of care process for disease state monitoring and environmental exposure assessment in human beings. Some VOCs/gases in exhaled breath are bio-markers of different diseases and their presence in excess amount is indicative of un-healthiness. Breath analysis has the potential for early detection of diseases. However, it is still underused and commercial device is yet not available owing to multiferrious challenges. This review is intended to provide an overview of major biomarkers (VOCs/gases) present in exhaled breath, importance of their analysis towards disease monitoring, analytical techniques involved, promising materials for breath analysis etc. Finally, related challenges and limitations along with future scope will be touched upon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Bootstrap methods: another look at the jackknife
Efron, B. (1979) · The Annals of Statistics · doi:10.1214/aos/1176344552 · Cited by 17,602
The L-Arginine-Nitric Oxide Pathway
Epstein, F. H., Moncada, S., & Higgs, A. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312303292706 · Cited by 6,678 · cited 1×
“—Nitric oxide (NO) has a critical role to play in the cell-signaling and its increased concentration in breath may be indicative of the pathophysiology of many diseases.(36,37) A large concentration of NO in exhaled breath is correlated with asthma.”
BackgroundKernel Methods for Pattern Analysis
Shawe-Taylor, J., & Cristianini, N. (2004) · Cambridge University Press eBooks · doi:10.1017/cbo9780511809682 · Cited by 6,587
Carbon Nanotubes: Present and Future Commercial Applications
De Volder, M. F. L., Tawfick, S. H., Baughman, R. H., & Hart, A. J. (2013) · Science · doi:10.1126/science.1222453 · Cited by 5,587
Nitric oxide as a secretory product of mammalian cells
Nathan, C. (1992) · The FASEB Journal · doi:10.1096/fasebj.6.12.1381691 · Cited by 4,350
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
Highly sensitive and selective gas sensors using p-type oxide semiconductors: Overview
Kim, H.-J., & Lee, J.-H. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.11.005 · Cited by 2,258
Two's company, three's a crowd: can H 2 S be the third endogenous gaseous transmitter?
Wang, R. (2002) · The FASEB Journal · doi:10.1096/fj.02-0211hyp · Cited by 1,807
Reduced Graphene Oxide Molecular Sensors
Robinson, J. T., Perkins, F. K., Snow, E. S., Wei, Z., & Sheehan, P. E. (2008) · Nano Letters · doi:10.1021/nl8013007 · Cited by 1,772
Adsorption ofH2O,NH3, CO,NO2, and NO on graphene: A first-principles study
Leenaerts, O., Partoens, B., & Peeters, F. M. (2008) · Physical Review B · doi:10.1103/physrevb.77.125416 · Cited by 1,709
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Practical Chemical Sensors from Chemically Derived Graphene
Fowler, J. D., Allen, M. J., Tung, V. C., Yang, Y., Kaner, R. B., & Weiller, B. H. (2009) · ACS Nano · doi:10.1021/nn800593m · Cited by 1,447
Grain size effects on gas sensitivity of porous SnO2-based elements
Xu, C., Tamaki, J., Miura, N., & Yamazoe, N. (1991) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(91)80207-z · Cited by 1,426
Sensing Behavior of Atomically Thin-Layered MoS2 Transistors
Late, D. J., Huang, Y.-K., Liu, B., Acharya, J., Shirodkar, S. N., Luo, J., Yan, A., Charles, D., Waghmare, U. V., Dravid, V. P., et al. (2013) · ACS Nano · doi:10.1021/nn400026u · Cited by 1,374
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Quantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025
Intrinsic Response of Graphene Vapor Sensors
Dan, Y., Lu, Y., Kybert, N. J., Luo, Z., & Johnson, A. T. C. (2009) · Nano Letters · doi:10.1021/nl8033637 · Cited by 973
Fabrication of Flexible MoS2 Thin‐Film Transistor Arrays for Practical Gas‐Sensing Applications
He, Q., Zeng, Z., Yin, Z., Li, H., Wu, S., Huang, X., & Zhang, H. (2012) · Small · doi:10.1002/smll.201201224 · Cited by 925
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Carbon Nanotube Gas and Vapor Sensors
Kauffman, D. R., & Star, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704488 · Cited by 828
Human exhaled air analytics: biomarkers of diseases
Buszewski, B., Kęsy, M., Ligor, T., & Amann, A. (2007) · Biomedical Chromatography · doi:10.1002/bmc.835 · Cited by 792
Flexible Graphene-Based Wearable Gas and Chemical Sensors
Singh, E., Meyyappan, M., & Nalwa, H. S. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07063 · Cited by 776
Peng, G., Hakim, M., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., Tisch, U., & Haick, H. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605810 · Cited by 775
Aldehyde Sources, Metabolism, Molecular Toxicity Mechanisms, and Possible Effects on Human Health
O'Brien, P. J., Siraki, A. G., & Shangari, N. (2005) · Critical Reviews in Toxicology · doi:10.1080/10408440591002183 · Cited by 738
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
(1936) · Nature · doi:10.1038/137559c0 · Cited by 694
Recent progress in carbon nanotube-based gas sensors
Zhang, T., Mubeen, S., Myung, N. V., et al. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/33/332001 · Cited by 666
Di Natale, C., Macagnano, A., Martinelli, E., Paolesse, R., D'Arcangelo, G., Roscioni, C., Finazzi-Agrò, A., & D'Amico, A. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00086-1 · Cited by 663
Righettoni, M., Tricoli, A., & Pratsinis, S. E. (2010) · Analytical Chemistry · doi:10.1021/ac902695n · Cited by 630
Noninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Gas sensing characteristics of multi-wall carbon nanotubes
Varghese, O. K., Kichambre, P. D., Gong, D., Ong, K. G., Dickey, E. C., & Grimes, C. A. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00923-6 · Cited by 590
Hydrogen sulfide (H2S) - the third gas of interest for pharmacologists.
Łowicka, E., & Bełtowski, J. (2007) · PubMed · Cited by 557
Vanadium Pentoxide Nanobelts: Highly Selective and Stable Ethanol Sensor Materials
Liu, J., Wang, X., Peng, Q., & Li, Y. (2005) · Advanced Materials · doi:10.1002/adma.200400993 · Cited by 546
Hydrogen sulfide as a gasotransmitter
Gadalla, M. M., & Snyder, S. H. (2010) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2010.06580.x · Cited by 498
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Role of Defects in Single-Walled Carbon Nanotube Chemical Sensors
Robinson, J. A., Snow, E. S., Bǎdescu, Ş. C., Reinecke, T. L., & Perkins, F. K. (2006) · Nano Letters · doi:10.1021/nl0612289 · Cited by 455
Ethane Evolution: A New Index of Lipid Peroxidation
Riely, C. A., Cohen, G., & Lieberman, M. (1974) · Science · doi:10.1126/science.183.4121.208 · Cited by 449
Kharitonov, S., Yates, D., & Barnes, P. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08020295 · Cited by 410
An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD
Dragonieri, S., Annema, J. T., Schot, R., van der Schee, M. P. C., Spanevello, A., Carratú, P., Resta, O., Rabe, K. F., & Sterk, P. J. (2009) · Lung Cancer · doi:10.1016/j.lungcan.2008.08.008 · Cited by 407
The selected ion flow tube (SIFT); A technique for studying ion-neutral reactions
Adams, N. G., & Smith, D. (1976) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(76)80133-7 · Cited by 397
Shin, J., Choi, S., Lee, I., Youn, D., Park, C. O., Lee, J., Tuller, H. L., & Kim, I. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201202729 · Cited by 391
Is overexpression of HER-2 a predictor of prognosis in colorectal cancer?
Kavanagh, D. O., Chambers, G., O' Grady, L., Barry, K. M., Waldron, R. P., Bennani, F., Eustace, P. W., & Tobbia, I. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-1 · Cited by 367
Current status of clinical breath analysis
Risby, T. H., & Solga, S. F. (2006) · Applied Physics B · doi:10.1007/s00340-006-2280-4 · Cited by 363
Ferroelectric WO3 Nanoparticles for Acetone Selective Detection
Wang, L., Teleki, A., Pratsinis, S. E., & Gouma, P. I. (2008) · Chemistry of Materials · doi:10.1021/cm800761e · Cited by 357
Detection of H2S down to ppb levels at room temperature using sensors based on ZnO nanorods
Wang, C., Chu, X., & Wu, M. M. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.03.011 · Cited by 340
An investigation on electronic nose diagnosis of lung cancer
D’Amico, A., Pennazza, G., Santonico, M., Martinelli, E., Roscioni, C., Galluccio, G., Paolesse, R., & Di Natale, C. (2010) · Lung Cancer · doi:10.1016/j.lungcan.2009.11.003 · Cited by 330
Diagnosis of lung cancer by the analysis of exhaled breath with a colorimetric sensor array
Mazzone, P. J., Hammel, J., Dweik, R., Na, J., Czich, C., Laskowski, D., & Mekhail, T. (2007) · Thorax · doi:10.1136/thx.2006.072892 · Cited by 329
Exhaled Nitric Oxide in Chronic Obstructive Pulmonary Disease
MAZIAK, W., LOUKIDES, S., CULPITT, S., SULLIVAN, P., KHARITONOV, S. A., & BARNES, P. J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.3.97-05009 · Cited by 324
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
CLINICAL ASSESSMENT OF BAD BREATH: CURRENT CONCEPTS
ROSENBERG, M. (1996) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1996.0239 · Cited by 316
Choi, S.-J., Lee, I., Jang, B.-H., Youn, D.-Y., Ryu, W.-H., Park, C. O., & Kim, I.-D. (2013) · Analytical Chemistry · doi:10.1021/ac303148a · Cited by 311
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Measurement of Oral Malodor: Current Methods and Future Prospects
Rosenberg, M., & McCulloch, C. A. G. (1992) · Journal of Periodontology · doi:10.1902/jop.1992.63.9.776 · Cited by 308
Exhaled Ethane, a Marker of Lipid Peroxidation, Is Elevated in Chronic Obstructive Pulmonary Disease
PAREDI, P., KHARITONOV, S. A., LEAK, D., WARD, S., CRAMER, D., & BARNES, P. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9909025 · Cited by 297
Synthesis and H2S Sensing Properties of CuO−SnO2 Core/Shell PN-Junction Nanorods
Xue, X., Xing, L., Chen, Y., Shi, S., Wang, Y., & Wang, T. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp8037818 · Cited by 277
A nanomaterial-based breath test for distinguishing gastric cancer from benign gastric conditions
Xu, Z.-Q., Broza, Y. Y., Ionsecu, R., Tisch, U., Ding, L., Liu, H., Song, Q., Pan, Y.-Y., Xiong, F.-X., Gu, K.-S., et al. (2013) · British Journal of Cancer · doi:10.1038/bjc.2013.44 · Cited by 271
Baron, R., & Saffell, J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00620 · Cited by 270
Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling
Karl, T., Prazeller, P., Mayr, D., Jordan, A., Rieder, J., Fall, R., & Lindinger, W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.762 · Cited by 264
Electrical conductivity and gas sensing properties of MoO3
Sunu, S. S., Prabhu, E., Jayaraman, V, Gnanasekar, K. I., Seshagiri, T. K., & Gnanasekaran, T. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.02.048 · Cited by 260
Exhaled nitric oxide: a new lung function test.
Barnes, P. J., & Kharitonov, S. A. (1996) · Thorax · doi:10.1136/thx.51.3.233 · Cited by 259
Shehada, N., Brönstrup, G., Funka, K., Christiansen, S., Leja, M., & Haick, H. (2015) · Nano Letters · doi:10.1021/nl504482t · Cited by 255
Kim, S.-J., Choi, S.-J., Jang, J.-S., Kim, N.-H., Hakim, M., Tuller, H. L., & Kim, I.-D. (2016) · ACS Nano · doi:10.1021/acsnano.6b01196 · Cited by 249
Breath Analysis for Clinical Diagnosis and Therapeutic Monitoring
(2005) · doi:10.1142/5796 · Cited by 247
Mazzone, P. J., Wang, X.-F., Xu, Y., Mekhail, T., Beukemann, M. C., Na, J., Kemling, J. W., Suslick, K. S., & Sasidhar, M. (2012) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318233d80f · Cited by 247
A review of the current literature on aetiology and measurement methods of halitosis
van den Broek, A. M. W. T., Feenstra, L., & de Baat, C. (2007) · Journal of Dentistry · doi:10.1016/j.jdent.2007.04.009 · Cited by 245
Kim, N.-H., Choi, S.-J., Yang, D.-J., Bae, J., Park, J., & Kim, I.-D. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.12.011 · Cited by 245
Selective sensing of NH 3 by Si-doped α-MoO 3 for breath analysis
Güntner, A. T., Righettoni, M., & Pratsinis, S. E. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.09.094 · Cited by 241
NH3 gas sensing performance enhanced by Pt-loaded on mesoporous WO3
Wang, Y., Liu, J., Cui, X., Gao, Y., Ma, J., Sun, Y., Sun, P., Liu, F., Liang, X., Zhang, T., et al. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.07.085 · Cited by 241
Kwak, D., Wang, M., Koski, K. J., Zhang, L., Sokol, H., Maric, R., & Lei, Y. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b20502 · Cited by 240
Diskin, A. M., pan l, P., & Smith, D. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/308 · Cited by 237
H2S sensors based on tungsten oxide nanostructures
Rout, C. S., Hegde, M., & Rao, C. N. R. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.07.013 · Cited by 237
Peng, G., Trock, E., & Haick, H. (2008) · Nano Letters · doi:10.1021/nl801577u · Cited by 228
Tisch, U., Schlesinger, I., Ionescu, R., Nassar, M., Axelrod, N., Robertman, D., Tessler, Y., Azar, F., Marmur, A., Aharon-Peretz, J., et al. (2013) · Nanomedicine · doi:10.2217/nnm.12.105 · Cited by 223
Sub-ppm H2S sensing at room temperature using CuO thin films
Ramgir, N. S., Ganapathi, S. K., Kaur, M., Datta, N., Muthe, K. P., Aswal, D. K., Gupta, S. K., & Yakhmi, J. V. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.09.043 · Cited by 221
O'CONNOR, T., IRELAND, L. S., HARRISON, D. J., & HAYES, J. D. (1999) · Biochemical Journal · doi:10.1042/bj3430487 · Cited by 217
Diagnosis of head-and-neck cancer from exhaled breath
Hakim, M., Billan, S., Tisch, U., Peng, G., Dvrokind, I., Marom, O., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2011) · British Journal of Cancer · doi:10.1038/bjc.2011.128 · Cited by 217
Li, S., Lin, P., Zhao, L., Wang, C., Liu, D., Liu, F., Sun, P., Liang, X., Liu, F., Yan, X., et al. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.11.081 · Cited by 215
Enhanced H2S sensing characteristics of SnO2 nanowires functionalized with CuO
Hwang, I.-S., Choi, J.-K., Kim, S. J., Dong, K., Kwon, J.-H., Ju, B., & Lee, J. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.07.052 · Cited by 212
Applications of breath gas analysis in medicine
Amann, A., Poupart, G., Telser, S., Ledochowski, M., Schmid, A., & Mechtcheriakov, S. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.08.010 · Cited by 208
Popov, T. A. (2011) · Annals of Allergy, Asthma & Immunology · doi:10.1016/j.anai.2011.02.016 · Cited by 206
Choi, K.-I., Kim, H.-J., Kang, Y. C., & Lee, J.-H. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.12.111 · Cited by 198
Montuschi, P., Santonico, M., Mondino, C., Pennazza, G., Mantini, G., Martinelli, E., Capuano, R., Ciabattoni, G., Paolesse, R., Di Natale, C., et al. (2010) · Chest · doi:10.1378/chest.09-1836 · Cited by 198
Non-invasive Breath Analysis of Pulmonary Nodules
Peled, N., Hakim, M., Bunn, P. A., Miller, Y. E., Kennedy, T. C., Mattei, J., Mitchell, J. D., Hirsch, F. R., & Haick, H. (2012) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e3182637d5f · Cited by 194
Duy, L. T., Kim, D., Trung, T. Q., Dang, V. Q., Kim, B., Moon, H. K., & Lee, N. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201401992 · Cited by 192
CuO Nanosheets for Sensitive and Selective Determination of H2S with High Recovery Ability
Zhang, F., Zhu, A., Luo, Y., Tian, Y., Yang, J., & Qin, Y. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp106098z · Cited by 192
Jeevitha, G., Abhinayaa, R., Mangalaraj, D., Ponpandian, N., Meena, P., Mounasamy, V., & Madanagurusamy, S. (2019) · Nanoscale Advances · doi:10.1039/c9na00048h · Cited by 192
ZnO hollow spheres: Preparation, characterization, and gas sensing properties
Zhang, J., Wang, S., Wang, Y., Xu, M., Xia, H., Zhang, S., Huang, W., Guo, X., & Wu, S. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.03.014 · Cited by 191
Point-of-care breath test for biomarkers of active pulmonary tuberculosis
Phillips, M., Basa-Dalay, V., Blais, J., Bothamley, G., Chaturvedi, A., Modi, K. D., Pandya, M., Natividad, M. P. R., Patel, U., Ramraje, N. N., et al. (2012) · Tuberculosis · doi:10.1016/j.tube.2012.04.002 · Cited by 190
Breath Ammonia Measurement in Helicobacter pylori Infection
Kearney, D. J., Hubbard, T., & Putnam, D. (2002) · Digestive Diseases and Sciences · doi:10.1023/a:1020568227868 · Cited by 188
Analysis of volatile organic compounds in exhaled breath to diagnose ventilator-associated pneumonia
Schnabel, R., Fijten, R., Smolinska, A., Dallinga, J., Boumans, M.-L., Stobberingh, E., Boots, A., Roekaerts, P., Bergmans, D., & van Schooten, F. J. (2015) · Scientific Reports · doi:10.1038/srep17179 · Cited by 182
Liu, W., Xu, L., Sheng, K., Zhou, X., Dong, B., Lu, G., & Song, H. (2018) · NPG Asia Materials · doi:10.1038/s41427-018-0029-2 · Cited by 182
Current status of midinfrared quantum and interband cascade lasers for clinical breath analysis
Tittel, F. K. (2010) · Optical Engineering · doi:10.1117/1.3498768 · Cited by 181
The Novel Selected-ion Flow Tube Approach to Trace Gas Analysis of Air and Breath
Smith, D. C., & Španěl, P. (1996) · Rapid Communications in Mass Spectrometry · Cited by 177
Exhaled breath analysis for lung cancer.
Dent, A. G., Sutedja, T. G., & Zimmerman, P. V. (2013) · PubMed · doi:10.3978/j.issn.2072-1439.2013.08.44 · Cited by 175
Hydrogen sulfide: its production and functions
Kimura, H. (2011) · Experimental Physiology · doi:10.1113/expphysiol.2011.057455 · Cited by 170
Highly sensitive NH3 sensor using Pt catalyzed silica coating over WO3 thick films
Srivastava, V., & Jain, K. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2008.01.066 · Cited by 167
Airway nitric oxide in asthmatic children and patients with cystic fibrosis
Dotsch, J., Demirakca, S., Terbrack, H., Huls, G., Rascher, W., & Kuhl, P. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09122537 · Cited by 166
Jang, J., Choi, S., Kim, S., Hakim, M., & Kim, I. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201600797 · Cited by 165
Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity
Wang, T., Pysanenko, A., Dryahina, K., Španěl, P., & Smith, D. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037013 · Cited by 164
Exhaled Pentane and Nitric Oxide Levels in Patients With Obstructive Sleep Apnea
Olopade, C. O., Christon, J. A., Zakkar, M., Swedler, W. I., Rubinstein, I., Hua, C.-W., & Scheff, P. A. (1997) · Chest · doi:10.1378/chest.111.6.1500 · Cited by 158
A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs
Kao, K.-W., Hsu, M.-C., Chang, Y.-H., Gwo, S., & Yeh, J. A. (2012) · Sensors · doi:10.3390/s120607157 · Cited by 158
Suehiro, J., Zhou, G., Imakiire, H., Ding, W., & Hara, M. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.09.048 · Cited by 157
Breath Ammonia Analysis: Clinical Application and Measurement
Hibbard, T., & Killard, A. J. (2011) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2011.521729 · Cited by 157
Li, F., Zhang, T., Gao, X. G., Wang, R., & Li, B. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.06.077 · Cited by 157
Cheng, L., Ma, S. Y., Li, X. B., Luo, J. L., Li, W. Q., Li, F., Mao, Y. Z., Wang, T. T., & Li, Y. F. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.04.063 · Cited by 154
Tunable Reverse‐Biased Graphene/Silicon Heterojunction Schottky Diode Sensor
Singh, A. K., Uddin, M. A., Sudarshan, T. S., et al. (2013) · Small · doi:10.1002/smll.201302818 · Cited by 153
Grisolı́a, S., Báguena, R., & Mayor, F. (1976) · Wiley eBooks · Cited by 150
Turner, C., Španěl, P., & Smith, D. C. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/007 · Cited by 150
Wang, X., Gu, D., Li, X., Lin, S., Zhao, S., Rumyantseva, M. N., & Gaskov, A. M. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.11.080 · Cited by 150
Chen, X., Cao, M., Li, Y., et al. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/8/001 · Cited by 148
Dragonieri, S., van der Schee, M. P., Massaro, T., Schiavulli, N. A., Brinkman, P., Pinca, A., Carratù, P., Spanevello, A., Resta, O., Musti, M., et al. (2011) · Lung Cancer · doi:10.1016/j.lungcan.2011.08.009 · Cited by 146
Zhang, D., Jiang, C., & Sun, Y. (2016) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2016.12.222 · Cited by 144
Nanosensor and Breath Analyzer for Ammonia Detection in Exhaled Human Breath
Gouma, P., Kalyanasundaram, K., Yun, X., Stanaćević, M., & Wang, L. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2036050 · Cited by 142
Liang, X., Kim, T. H., Yoon, J., Kwak, C.-H., & Lee, J. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.11.130 · Cited by 140
Tian, K., Wang, X., Yu, Z., Li, H., & Guo, X. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07069 · Cited by 140
Lipid peroxidation and plasma antioxidant micronutrients in Crohn disease
Wendland, B. E., Aghdassi, E., Tam, C., Carrrier, J., Steinhart, A. H., Wolman, S. L., Baron, D., & Allard, J. P. (2001) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/74.2.259 · Cited by 139
Sun, P., Cai, Y., Du, S., Xu, X., You, L., Ma, J., Liu, F., Liang, X., Sun, Y., & Lu, G. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.03.019 · Cited by 139
Carbon nanotube sensors for exhaled breath components
Kuzmych, O., Allen, B. L., & Star, A. (2007) · Nanotechnology · doi:10.1088/0957-4484/18/37/375502 · Cited by 139
Kim, N. H., Choi, S., Kim, S., Cho, H., Jang, J., Koo, W., Kim, M., & Kim, I. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.10.021 · Cited by 139
A nanomaterial-based breath test for short-term follow-up after lung tumor resection
Broza, Y. Y., Kremer, R., Tisch, U., Gevorkyan, A., Shiban, A., Best, L. A., & Haick, H. (2012) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2012.07.009 · Cited by 138
Cardiovascular Biomarkers in Exhaled Breath
Cikach, F. S., & Dweik, R. A. (2012) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.05.005 · Cited by 137
Role of hydrogen sulfide in secondary neuronal injury
Wang, J., Li, Y., Song, J., & Pang, H. (2013) · Neurochemistry International · doi:10.1016/j.neuint.2013.11.002 · Cited by 136
Ionescu, R., Broza, Y. Y., Shaltieli, H., Sadeh, D., Zilberman, Y., Feng, X., Glass‐Marmor, L., Lejbkowicz, I., Müllen, K., Miller, A., et al. (2011) · ACS Chemical Neuroscience · doi:10.1021/cn2000603 · Cited by 135
A breath test for malignant mesothelioma using an electronic nose
Chapman, E. A., Thomas, P. S., Stone, E. C. A., Lewis, C. R., & Yates, D. H. (2011) · European Respiratory Journal · doi:10.1183/09031936.00040911 · Cited by 133
Jeong, S., Yoon, J., Kim, T.-H., Jeong, H.-M., Lee, C.-S., Kang, Y. C., & Lee, J. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta09397c · Cited by 133
One-pot hydrothermal synthesis of CuO–ZnO composite hollow spheres for selective H2S detection
Kim, S.-J., Na, C. W., Hwang, I.-S., & Lee, J. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.01.045 · Cited by 130
Hanouneh, I. A., Zein, N. N., Cikach, F. S., Dababneh, L., Grove, D., Alkhouri, N., López, R., & Dweik, R. A. (2013) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2013.08.048 · Cited by 130
Diet and oxidative stress in breast, colon and prostate cancer patients: a case-control study.
Hietanen, E. K., Bartsch, H. S., Béréziat, J., Camus, A. ‐., McClinton, S., Eremin, O., Davidson, L., & Boyle, P. (1994) · PubMed · Cited by 127
Volatile metabolites in the exhaled breath of healthy volunteers: their levels and distributions
Smith, D. C., Turner, C., & Španěl, P. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/1/014004 · Cited by 127
Cho, Y. H., Ko, Y. N., Kang, Y. C., Kim, I., & Lee, J. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.01.021 · Cited by 127
Koo, W., Choi, S., Kim, N. H., Jang, J., & Kim, I. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.09.095 · Cited by 124
Toombs, C. F., Insko, M. A., Wintner, E. A., Deckwerth, T. L., Usansky, H. H., Jamil, K., Goldstein, B., Cooreman, M. P., & Szabó, C. (2010) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2010.03636.x · Cited by 121
Abokifa, A. A., Haddad, K., Fortner, J. D., Lo, C. S., & Biswas, P. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta09535j · Cited by 121
Morning Breath Odor: Influence of Treatments on Sulfur Gases
Suarez, F. L., Furne, J. K., Springfield, J. R., & Levitt, M. D. (2000) · Journal of Dental Research · doi:10.1177/00220345000790100701 · Cited by 118
Acetone, ammonia and hydrogen cyanide in exhaled breath of several volunteers aged 4–83 years
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/1/011001 · Cited by 116
Godish, T. (2019) · CRC Press eBooks · doi:10.1201/9781351073486 · Cited by 116
Moon, H. G., Choi, Y. R., Shim, Y., Choi, K.-I., Lee, J., Kim, J.-S., Yoon, S.-J., Park, H., Kang, C., & Jang, H. W. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am402456s · Cited by 114
Koo, W., Choi, S., Jang, J., et al. (2017) · Scientific Reports · doi:10.1038/srep45074 · Cited by 114
Ma, J., Mei, L., Chen, Y., Li, Q., Wang, T., Xu, Z. Q., Duan, X., & Zheng, W. (2012) · Nanoscale · doi:10.1039/c2nr33201a · Cited by 113
Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications
Hemmingsson, T. E., Linnarsson, D., & Gambert, R. (2004) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-1158-z · Cited by 112
Ultrasensitive and selective C2H5OH sensors using Rh-loaded In2O3 hollow spheres
Kim, S. J., Hwang, I.-S., Na, C. W., Kim, I., Kang, Y. C., & Lee, J. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm14252f · Cited by 109
Minitha, C. R., Anithaa, V. S., Vijayakumar, S., & Kumar, R. T. R. (2018) · ACS Omega · doi:10.1021/acsomega.7b02085 · Cited by 108
Nixon, C. C., Schwartz, B. H., Dixit, D., Zack, J. A., & Vatakis, D. N. (2015) · Scientific Reports · doi:10.1038/srep09798 · Cited by 104
Alkhouri, N., Cikach, F. S., Eng, K., Moses, J., Patel, N., Chen, Y., Hanouneh, I. A., Grove, D., López, R., & Dweik, R. A. (2013) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0b013e3283650669 · Cited by 102
Taucher, J., Hansel, A., Jordan, A., Fall, R., Futrell, J. H., & Lindinger, W. (1997) · Rapid Communications in Mass Spectrometry · Cited by 102
Smith, D. C., Španěl, P., Enderby, B., Lenney, W., Turner, C., & Davies, S. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/4/1/017101 · Cited by 101
Classification of breast cancer precursors through exhaled breath
Shuster, G., Gallimidi, Z., Heyman‐Reiss, A., Dovgolevsky, E., Billan, S., Abdah‐Bortnyak, R., Kuten, A., Engel, A., Shiban, A., Tisch, U., et al. (2010) · Breast Cancer Research and Treatment · doi:10.1007/s10549-010-1317-x · Cited by 101
Beccaria, M., Bobak, C. A., Boitumelo, M., Mellors, T. R., Purcaro, G., Franchina, F. A., Rees, C. A., Nasir, M., Black, A. D., & Hill, J. E. (2018) · Journal of Breath Research · doi:10.1088/1752-7163/aae80e · Cited by 100
Crofford, O. B., Mallard, R., Winton, R. E., Rogers, N. L., Jackson, J. C., & Keller, U. (1977) · PubMed Central · Cited by 98
Perovskite hexagonal YMnO3 nanopowder as p-type semiconductor gas sensor for H2S detection
Balamurugan, C., & Lee, D.-W. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.07.018 · Cited by 98
Monitoring ammonia to assess halitosis
Amano, A., Yoshida, Y., Oho, T., & Koga, T. (2002) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1067/moe.2002.126911 · Cited by 98
Bilayer SnO2–WO3 nanofilms for enhanced NH3 gas sensing performance
Toàn, N. V., Hung, C. M., Duy, N. V., Hòa, N. Đ., Le, D. T. T., & Hiếu, N. V. (2017) · Materials Science and Engineering B · doi:10.1016/j.mseb.2017.08.004 · Cited by 98
Navale, S. T., Liu, C., Gaikar, P. S., Patil, V. B., Sagar, R. U. R., Du, B., Mane, R. S., & Stadler, F. J. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.01.195 · Cited by 97
Enhanced ammonia sensing at room temperature with reduced graphene oxide/tin oxide hybrid films
Ghosh, R., Nayak, A. K., Santra, S., Pradhan, D., & Guha, P. K. (2015) · RSC Advances · doi:10.1039/c5ra06696d · Cited by 95
Narjinary, M. B., Rana, P., Sen, A., & Pal, M. (2016) · Materials & Design · doi:10.1016/j.matdes.2016.11.042 · Cited by 94
Self-citationChoi, S., Kim, S., Cho, H., Jang, J., Lin, Y., Tuller, H. L., Rutledge, G. C., & Kim, I. (2016) · Small · doi:10.1002/smll.201502905 · Cited by 89
Inflammometry to assess airway diseases
Pavord, I. D., Shaw, D. E., Gibson, P. G., & Taylor, D. R. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61421-x · Cited by 88
Chakraborty, S., & Pal, M. (2019) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2019.02.153 · Cited by 88
Self-citationHighly Sensitive Nitric Oxide Sensing Using Three‐Dimensional Graphene/Ionic Liquid Nanocomposite
Ng, S. R., Guo, C., & Li, C. M. (2010) · Electroanalysis · doi:10.1002/elan.201000344 · Cited by 87
Bioelectronic sniffers for ethanol and acetaldehyde in breath air after drinking
Mitsubayashi, K., Matsunaga, H., Nishio, G., Toda, S., & Nakanishi, Y. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.007 · Cited by 87
Yebo, N. A., Sree, S. P., Levrau, E., Detavernier, C., Hens, Z., Martens, J. A., & Baets, R. (2012) · Optics Express · doi:10.1364/oe.20.011855 · Cited by 86
Methods of NO detection in exhaled breath
Cristescu, S. M., Mandon, J., Harren, F. J. M., Meriläinen, P., & Högman, M. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/1/017104 · Cited by 84
Gholizadeh, A., Voiry, D., Weisel, C. P., Gow, A. J., Laumbach, R. J., Kipen, H. M., Chhowalla, M., & Javanmard, M. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.22 · Cited by 83
Lamote, K., Brinkman, P., Vandermeersch, L., Vynck, M., Sterk, P. J., Langenhove, H. R. V., Thas, O., Cleemput, J. V., Nackaerts, K., & van Meerbeeck, J. P. (2017) · Oncotarget · doi:10.18632/oncotarget.21335 · Cited by 83
Neuroprotection in cerebral ischemia by neutralization of 3-aminopropanal
Ivanova, S., Batliwalla, F., Mocco, J., Kiss, S., Huang, J., Mack, W. J., Coon, A. L., Eaton, J. W., Al‐Abed, Y., Gregersen, P. K., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082609299 · Cited by 82
Molybdenum trioxide nanopaper as a dual gas sensor for detecting trimethylamine and hydrogen sulfide
Li, H., Huang, L., Wang, X., Lee, C.-S., Yoon, J., Zhou, J., Guo, X., & Lee, J. (2017) · RSC Advances · doi:10.1039/c6ra26280e · Cited by 82
Samara, M. A., Tang, W. H. W., Cikach, F. S., Gul, Z., Tranchito, L. J., Paschke, K. M., Viterna, J., Wu, Y., Laskowski, D. M., & Dweik, R. A. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.12.033 · Cited by 81
Gender and age specific differences in exhaled isoprene levels
Lechner, M., Moser, B., Niederseer, D., Karlseder, A., Holzknecht, B., Fuchs, M., Colvin, S., Tilg, H., & Rieder, J. (2006) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.01.007 · Cited by 79
Breath Isoprene in Patients with Heart Failure
McGrath Lawrence, T., Robin, P., & Bernard, S. (2001) · European Journal of Heart Failure · doi:10.1016/s1388-9842(01)00128-3 · Cited by 78
Sun, C., Maduraiveeran, G., & Dutta, P. K. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.05.090 · Cited by 76
Storer, M., Dummer, J. F., Lunt, H., Scotter, J., McCartin, F., Cook, J., Swanney, M. P., Kendall, D., Logan, F. J., & Epton, M. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/4/046011 · Cited by 73
A novel MVA-mediated pathway for isoprene production in engineered E. coli
Yang, J., Nie, Q., Liu, H., Xian, M., & Liu, H. (2016) · BMC Biotechnology · doi:10.1186/s12896-016-0236-2 · Cited by 73
Giardina, M., & Olesik, S. V. (2003) · Analytical Chemistry · doi:10.1021/ac025984k · Cited by 72
3-Aminopropanal, formed during cerebral ischaemia, is a potent lysosomotropic neurotoxin
Li, W., Yuan, X., Ivanova, S., Tracey, K. J., Eaton, J. W., & Brunk, U. T. (2003) · Biochemical Journal · doi:10.1042/bj20021520 · Cited by 71
One-dimensional CuO–SnO2 p–n heterojunctions for enhanced detection of H2S
Giebelhaus, I., Varechkina, E., Fischer, T., Rumyantseva, M. N., Ivanov, V. K., Gaskov, A. M., Morante, J. R., Arbiol, J., Tyrra, W., & Mathur, S. (2013) · Journal of Materials Chemistry A · doi:10.1039/c3ta11867c · Cited by 71
Shinpo, K., Kikuchi, S., Sasaki, H., Ogata, A., Moriwaka, F., & Tashiro, K. (2000) · Brain Research · doi:10.1016/s0006-8993(00)02047-3 · Cited by 70
Timms, C., Thomas, P. S., & Yates, D. H. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/1/016003 · Cited by 68
Room temperature ppb level H2S detection of a single Sb-doped SnO2 nanoribbon device
Ma, J., Liu, Y., Zhang, H., Ai, P., Gong, N., Wu, Y., & Yu, D. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.04.025 · Cited by 67
O'Connor, T., Ireland, L. S., Harrison, D. J., et al. (1999) · Biochemical Journal · doi:10.1042/0264-6021:3430487 · Cited by 66
Methods for measuring ethane and pentane in expired air from rats and humans
Knutson, M. D., Handelman, G. J., & Viteri, F. E. (2000) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(99)00230-0 · Cited by 64
Electrochemical sensor system for breath analysis of aldehydes, CO and NO
Obermeier, J., Trefz, P., Wex, K., Sabel, B., Schubert, J. K., & Miekisch, W. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/1/016008 · Cited by 63
Breath pentane and plasma lipid peroxides in ischemic heart disease
Mendis, S., Sobotka, P. A., Leia, F. L., & Euler, D. E. (1995) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(95)00053-z · Cited by 61
Quantification of hydrogen cyanide in humid air by selected ion flow tube mass spectrometry
Španěl, P., Wang, T., & Smith, D. C. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1566 · Cited by 61
BaTiO3 nanostructures for H2S gas sensor: Influence of band-gap, size and shape on sensing mechanism
Patil, R. S., More, P. V., Jain, G. H., Khanna, P. K., & Gaikwad, V. B. (2017) · Vacuum · doi:10.1016/j.vacuum.2017.08.008 · Cited by 60
Benzene in the blood and breath of normal people and occupationally exposed workers
Brugnone, F., Perbellini, L., Faccini, G., et al. (1989) · American Journal of Industrial Medicine · doi:10.1002/ajim.4700160406 · Cited by 59
Detection of amines with chromium-doped WO3 mesoporous material
Zamani, C., Casals, O., Andreu, T., Morante, J. R., & Romano-Rodriguez, A. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.04.051 · Cited by 58
Incalzi, R. A., Pennazza, G., Scarlata, S., Santonico, M., Petriaggi, M., Chiurco, D., Pedone, C., Arnaldo, & D'Amico (2012) · PLoS ONE · doi:10.1371/journal.pone.0045396 · Cited by 56
Kim, K., Kim, S., Cho, H., Kim, N. H., Jang, J., Choi, S., & Kim, I. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.09.192 · Cited by 55
Breath condensate ammonium is lower in children with chronic asthma
MacGregor, G., Ellis, S., Andrews, J., Imrie, M., Innes, A., Greening, A. P., & Cunningham, S. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00106204 · Cited by 52
Diskin, A. M., Španěl, P., & Smith, D. C. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/314 · Cited by 47
Exhaled breath analysis for gastric cancer diagnosis in Colombian patients
Acevedo, C. M. D., Jaimes‐Mogollón, A. L., Guerrero, Ó. E. G., Welearegay, T. G., Marín, J. D. M., Cáceres-Tarazona, J. M., Sánchez-Acevedo, Z. C., Sáenz, K. D. J. B., Çindemir, U., Österlund, L., et al. (2018) · Oncotarget · doi:10.18632/oncotarget.25331 · Cited by 47
Highly Sensitive and Selective H2S Chemical Sensor Based on ZnO Nanomaterial
Galstyan, V., Poli, N., & Comini, E. (2019) · Applied Sciences · doi:10.3390/app9061167 · Cited by 42
Mesoporous WO3 Nanofibers With Crystalline Framework for High-Performance Acetone Sensing
Xu, H., Gao, J., Li, M., Zhao, Y., Zhang, M., Zhao, T., Wang, L., Jiang, W., Zhu, G., Qian, X., et al. (2019) · Frontiers in Chemistry · doi:10.3389/fchem.2019.00266 · Cited by 42
Electronic Nose Breathprints Are Independent of Acute Changes in Airway Caliber in Asthma
Lázár, Z., Fens, N., van der Maten, J., van der Schee, M. P., Wagener, A. H., de Nijs, S. B., Dijkers, E., & Sterk, P. J. (2010) · Sensors · doi:10.3390/s101009127 · Cited by 41
Kim, I., Choi, S., Kim, S., & Jang, J.-S. (2015) · KAIST research series · doi:10.1007/978-94-017-9981-2_2 · Cited by 41
Enhanced acetone gas sensing properties by aurelia-like SnO 2 micro-nanostructures
Yu, H. Y., Wang, S., Xiao, C., Xiao, B., Wang, P., Li, Z., & Zhang, M. (2015) · CrystEngComm · doi:10.1039/c5ce00448a · Cited by 39
Thangamuthu, M., Manickam, P., Balamurugan, M., Karnewar, S., Benjamin, A. R., Venkatesh, K., Kanagavel, V., Kotamraju, S., & Karunakaran, C. (2012) · Talanta · doi:10.1016/j.talanta.2012.08.033 · Cited by 39
CURRENT STATUS OF CLINICAL BREATH ANALYSIS
Risby, T. H. (2005) · doi:10.1142/9789812701954_0017 · Cited by 35
Facile synthesis of Ca 2+ /Au co-doped SnO 2 nanofibers and their application in acetone sensor
Jiang, Z., Yin, M., & Wang, C. (2017) · Materials Letters · doi:10.1016/j.matlet.2017.02.031 · Cited by 34
Cited by
Recent Progress on Flexible Room-Temperature Gas Sensors Based on Metal Oxide Semiconductor
Ou, L.-X., Liu, M.-Y., Zhu, L.-Y., Zhang, D. W., & Lu, H.-L. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00956-9 · Cited by 402
Electrospinning and Nanofiber Technology: Fundamentals, Innovations, and Applications
Cho, Y., Baek, J. W., Sagong, M., Ahn, S., Nam, J. S., & Kim, I. (2025) · Advanced Materials · doi:10.1002/adma.202500162 · Cited by 334
Chemiresistive Sensor Arrays for Gas/Volatile Organic Compounds Monitoring: A Review
Rath, R. J., Farajikhah, S., Oveissi, F., Dehghani, F., & Naficy, S. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202200830 · Cited by 183
Breath VOC analysis and machine learning approaches for disease screening: a review
P, H., Rangarajan, M., & Pandya, H. J. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/acb283 · Cited by 37
Binson, V. A., & Subramoniam, M. (2022) · Journal of Biomimetics, Biomaterials and Biomedical Engineering · doi:10.4028/p-dab04j · Cited by 14
Metadata
- Authors
- Das, S., & Pal, M.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2020-01-02
- Volume
- 167
- Issue
- 3
- Pages
- 037562
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W3004911392
- Cited by
- 466
- References
- 217
- FWCI
- 17.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.