Effects of Porous Carbon Morphology, Agglomerate Structure and Relative Humidity on Local Oxygen Transport Resistance
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The morphology and ionomer distribution in the polymer electrolyte membrane fuel cell (PEMFC) cathode electrode (used in Toyota Mirai) are quantified with nano-scale resolution X-ray computed tomography (nano-CT). Using the nano-CT data, different shapes, sizes and compositions of agglomerates are extracted. Statistical information from multiple techniques, including transmission electron microscopy (TEM), ultra-small angle X-ray scattering (USAXS), and Brunauer-Emmett-Teller (BET) gas adsorption porosimetry are combined to reconstruct the high surface-area porous carbon (HSC) support, exterior (on the surface of carbon) and interior (inside carbon pores) catalysts, ionomer, and primary pores in the extracted agglomerates. Application of capillary condensation theory to the reconstructed agglomerate structure is shown to accurately represent the experimentally-observed relative humidity (RH) dependence of the electrochemically-active surface area (ECA). Direct numerical simulations (DNS) show that the high local O 2 transport resistance ( ) under dry conditions is mainly associated with the reduced ECA. We demonstrate that the agglomerate shape and size affect only if the primary pores are poorly accessible (i.e., capillary-condensed water filled primary pores result in lower for lower aspect ratio agglomerates). We also estimate associated with the location of catalyst (whether inside or on the surface of HSC).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carbon supports for low-temperature fuel cell catalysts
Antolini, E. (2009) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2008.09.030 · Cited by 1,295
Kongkanand, A., & Mathias, M. F. (2016) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.6b00216 · Cited by 1,202
Koh, S., & Strasser, P. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0742784 · Cited by 783
Boosting Fuel Cell Performance with Accessible Carbon Mesopores
Yarlagadda, V., Carpenter, M. K., Moylan, T. E., Kukreja, R. S., Koestner, R., Gu, W., Thompson, L., & Kongkanand, A. (2018) · ACS Energy Letters · doi:10.1021/acsenergylett.8b00186 · Cited by 686
Soboleva, T., Zhao, X., Malek, K., Xie, Z., Navessin, T., & Holdcroft, S. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am900600y · Cited by 424
Park, Y.-C., Tokiwa, H., Kakinuma, K., Watanabe, M., & Uchida, M. (2016) · Journal of Power Sources · doi:10.1016/j.jpowsour.2016.02.091 · Cited by 389
Modelling the PEM fuel cell cathode
BROKA, K., & EKDUNGE, P. (1997) · Journal of Applied Electrochemistry · doi:10.1023/a:1018476612810 · Cited by 243
Ohma, A., Mashio, T., Sato, K., Iden, H., Ono, Y., Sakai, K., Akizuki, K., Takaichi, S., & Shinohara, K. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2011.04.058 · Cited by 209
Relationship among Microstructure, Ionomer Property and Proton Transport in Pseudo Catalyst Layers
Iden, H., Sato, K., Ohma, A., & Shinohara, K. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3598141 · Cited by 76
Cited by
New roads and challenges for fuel cells in heavy-duty transportation
Cullen, D. A., Neyerlin, K. C., Ahluwalia, R. K., Mukundan, R., More, K. L., Borup, R. L., Weber, A. Z., Myers, D. J., & Kusoglu, A. (2021) · Nature Energy · doi:10.1038/s41560-021-00775-z · Cited by 1,277
Self-citationElectrocatalysis in Alkaline Media and Alkaline Membrane-Based Energy Technologies
Yang, Y., Peltier, C. R., Zeng, R., Schimmenti, R., Li, Q., Huang, X., Yan, Z., Potsi, G., Selhorst, R., Lu, X., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00331 · Cited by 544
Pore-scale modeling of complex transport phenomena in porous media
Chen, L., He, A., Zhao, J., Kang, Q., Li, Z.-Y., Carmeliet, J., Shikazono, N., & Tao, W.-Q. (2022) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2021.100968 · Cited by 399
The Controllable Design of Catalyst Inks to Enhance PEMFC Performance: A Review
Guo, Y., Pan, F., Chen, W., Ding, Z., Yang, D., Li, B., Ming, P., & Zhang, C. (2021) · Electrochemical Energy Reviews · doi:10.1007/s41918-020-00083-2 · Cited by 175
“A high level of dispersion of catalyst particles and ionomers on Ketjen Black may be attributed to the fact that a large portion of the Pt in the interior of the carbon particles [71, 72].”
BackgroundVan Cleve, T., Khandavalli, S., Chowdhury, A., Medina, S., Pylypenko, S., Wang, M., More, K. L., Kariuki, N., Myers, D. J., Weber, A. Z., et al. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b17614 · Cited by 148
Self-citationVan Cleve, T., Wang, G., Mooney, M., Cetinbas, C. F., Kariuki, N., Park, J., Farghaly, A., Myers, D., & Neyerlin, K. C. (2021) · Journal of Power Sources · doi:10.1016/j.jpowsour.2020.228889 · Cited by 66
Self-citation
Metadata
- Authors
- Cetinbas, F. C., Ahluwalia, R. K., Kariuki, N. N., De Andrade, V., & Myers, D. J.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2019-09-23
- Volume
- 167
- Issue
- 1
- Pages
- 013508
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2975291351
- Cited by
- 79
- References
- 9
- FWCI
- 2.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.