The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Impact of Platinum Loading and Catalyst Layer Structure on PEMFC Performance
Abstract
Reducing Pt in proton exchange membrane fuel cells is the subject of intense research and development. Recently, researchers have observed significant performance loss due to a transport limitation at the Pt surface. This is investigated here with loading studies that fix electrode thickness and bulk properties. Within these layers, the impact of Pt dispersion is probed by varying the wt% of Pt/C while holding Pt loading and electrode thickness constant by diluting with carbon, effectively varying the average distance between Pt particles while maintaining gas phase loss in the catalyst layer. Results elucidate how the electrode structure impacts local transport loss. It is demonstrated that local transport loss is not fully captured with a normalized Pt area. Additional geometric considerations that account for ionomer surface area relative to the Pt particles are required to resolve performance loss at low Pt loading as electrode structure varies. Furthermore, within this ionomer layer an interfacial resistance at both the gas and Pt interfaces are necessary to account for performance trends observed. These results demonstrate that residual performance loss associated with low cathode Pt loading can be mitigated by electrode design, where oxygen flux through the gas/ionomer interface to the Pt surface is minimized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gasteiger, H. A., Kocha, S. S., Sompalli, B., & Wagner, F. T. (2005) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2004.06.021 · Cited by 4,876
Improved Oxygen Reduction Activity on Pt 3 Ni(111) via Increased Surface Site Availability
Stamenkovic, V. R., Fowler, B., Mun, B. S., Wang, G., Ross, P. N., Lucas, C. A., & Marković, N. M. (2007) · Science · doi:10.1126/science.1135941 · Cited by 4,421
Transient analysis of polymer electrolyte fuel cells
Wang, Y., & Wang, C.-Y. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.022 · Cited by 310
Ohma, A., Mashio, T., Sato, K., Iden, H., Ono, Y., Sakai, K., Akizuki, K., Takaichi, S., & Shinohara, K. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2011.04.058 · Cited by 209
Fuel cell catalyst layers containing short-side-chain perfluorosulfonic acid ionomers
Peron, J., Edwards, D., Haldane, M., Luo, X., Zhang, Y., Holdcroft, S., & Shi, Z. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2010.06.050 · Cited by 77
Cited by
Kongkanand, A., & Mathias, M. F. (2016) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.6b00216 · Cited by 1,202
Kodama, K., Nagai, T., Kuwaki, A., Jinnouchi, R., & Morimoto, Y. (2021) · Nature Nanotechnology · doi:10.1038/s41565-020-00824-w · Cited by 894
Ott, S., Orfanidi, A., Schmies, H., Anke, B., Nong, H. N., Hübner, J., Gernert, U., Gliech, M., Lerch, M., & Strasser, P. (2020) · Nature Materials · doi:10.1038/s41563-019-0487-0 · Cited by 727
Lazaridis, T., Stühmeier, B. M., Gasteiger, H. A., & El-Sayed, H. A. (2022) · Nature Catalysis · doi:10.1038/s41929-022-00776-5 · Cited by 396
The Key to High Performance Low Pt Loaded Electrodes
Orfanidi, A., Madkikar, P., El-Sayed, H. A., Harzer, G. S., Kratky, T., & Gasteiger, H. A. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.1621704jes · Cited by 276
Metadata
- Authors
- Owejan, J. P., Owejan, J. E., & Gu, W.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2013
- Volume
- 160
- Issue
- 8
- Pages
- F824-F833
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2008932415
- Cited by
- 423
- References
- 5
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Platinum Loading and Catalyst Layer Structure on PEMFC Performance. https://app.cochat.ai/papers/10.1149/2.072308jes
- The paper
- Owejan, J. P., Owejan, J. E., & Gu, W. (2013). Impact of Platinum Loading and Catalyst Layer Structure on PEMFC Performance. Journal of The Electrochemical Society. https://doi.org/10.1149/2.072308jes
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.