CoChat

Maintenance of the postabsorptive plasma glucose concentration: insulin or insulin plus glucagon?

Raju, Bharathi, Cryer, Philip E. · 2005 · American Journal of Physiology-Endocrinology and Metabolism
Cited by 42

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

The prevalent view is that the postabsorptive plasma glucose concentration is maintained within the physiological range by the interplay of the glucose-lowering action of insulin and the glucose-raising action of glucagon. It is supported by a body of evidence derived from studies of suppression of glucagon (and insulin, among other effects) with somatostatin in animals and humans, immunoneutralization of glucagon, defective glucagon synthesis, diverse mutations, and absent or reduced glucagon receptors in animals and glucagon antagonists in cells, animals, and humans. Many of these studies are open to alternative interpretations, and some lead to seemingly contradictory conclusions. For example, immunoneutralization of glucagon lowered plasma glucose concentrations in rabbits, but administration of a glucagon antagonist did not lower plasma glucose concentrations in healthy humans. Evidence that the glycemic threshold for glucagon secretion, unlike that for insulin secretion, lies below the physiological range, and the finding that selective suppression of insulin secretion without stimulation of glucagon secretion raises fasting plasma glucose concentrations in humans underscore the primacy of insulin in the regulation of the postabsorptive plasma glucose concentration and challenge the prevalent view. The alternative view is that the postabsorptive plasma glucose concentration is maintained within the physiological range by insulin alone, specifically regulated increments and decrements in insulin, and the resulting decrements and increments in endogenous glucose production, respectively, and glucagon becomes relevant only when glucose levels drift below the physiological range. Although the balance of evidence suggests that glucagon is involved in the maintenance of euglycemia, more definitive evidence is needed, particularly in humans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpendo.00460.2004

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 42

Metadata

Authors
Raju, B., & Cryer, P. E.
Venue
American Journal of Physiology-Endocrinology and Metabolism
Published
2005-08
Volume
289
Issue
2
Pages
E181-E186
ISSN
  • 0193-1849 (ISSN-L)
  • 1522-1555
OpenAlex
W2161811597
Cited by
42
References
13
FWCI
3.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Maintenance of the postabsorptive plasma glucose concentration: insulin or insulin plus glucagon? https://app.cochat.ai/papers/10.1152/ajpendo.00460.2004
The paper
Raju, B., & Cryer, P. E. (2005). Maintenance of the postabsorptive plasma glucose concentration: insulin or insulin plus glucagon? American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.00460.2004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.