Cited by 1,217Cardiovascular Function and Risk FactorsHeart Failure Treatment and ManagementCardiac pacing and defibrillation studies

Systolic Time Intervals in Heart Failure in Man

Open access
WEISSLER, ARNOLD M., HARRIS, WILLARD S., SCHOENFELD, CLYDE D.·1968·Circulation

Abstract

The duration of the systolic time intervals in nondigitalized patients with heart failure was determined from simultaneous fast speed recordings of the electrocardiogram, phonocardiogram, and carotid arterial pulsation. These were compared with the systolic time intervals corrected for heart rate and sex in 211 normal subjects. The failing left ventricle is characterized by a prolongation in the systolic pre-ejection period and a diminution in the left ventricular ejection time while total electromechanical systole remains relatively unaltered. Both components of the pre-ejection period, the Q-1 interval and the isovolumic contraction time, were prolonged. These alterations in the phases of systole occur in the absence of a measurable change in ventricular depolarization time. The prolongation in the pre-ejection period is well correlated with the reduced stroke volume and cardiac output in heart failure and is independently augmented by high levels of arterial pressure. The abbreviation in left ventricular ejection time is also correlated significantly with the stroke volume and cardiac output. It is postulated that a defect in the mechanical performance of the heart is responsible for the abnormal systolic time intervals in human heart failure.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.37.2.149

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • People suffering from heart failure exhibit a lengthening of PEP and shortening of LVET mostly due to a diminished rate of isovolumetric pressure rise, and an inability to maintain a high left ventricular pressure during the ejection period associated with decreased cardiac contractility.

    “People suffering from heart failure exhibit a lengthening of PEP and shortening of LVET mostly due to a diminished rate of isovolumetric pressure rise, and an inability to maintain a high LV pressure during the ejection period associated with decreased cardiac contractility, respectively.”

    From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [12]

    Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. SNEDECOR, G. W.: Statistical Methods, ed. 5. Ames, Iowa, The Iowa State College Press, 1956.

Cited by

Sorted by citations

Authors
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D.
Affiliations
The Ohio State University (US)
Venue
Circulation
Published
1968-02
Volume
37
Issue
2
Pages
149-159
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2000663038
Cited by
1,217
References
13
Citations by year
2026: 9 · 2025: 16 · 2024: 11 · 2023: 15 · 2022: 18 · 2021: 19 · 2020: 17 · 2019: 28 · 2018: 13 · 2017: 18 · 2016: 21 · 2015: 18 · 2014: 17 · 2013: 20 · 2012: 15
FWCI
40.75
Type
journal article
Language
en
Open access
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Funders
American Heart Association
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
systolic time intervals, heart failure, left ventricular ejection time, pre-ejection period, isovolumic contraction time, electromechanical systole, stroke volume, cardiac output, arterial pressure, left ventricular function, phonocardiography, carotid pulse
MeSH terms
Adult, Aged, Blood Pressure, Blood Volume, Cardiac Output, Carotid Arteries, Electrocardiography, Female, Heart Auscultation, Heart Failure, Heart Ventricles, Humans, Male, Methods, Middle Aged, Phonocardiography, Photography, Pulse

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review