Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
In 12 mechanically ventilated and anesthetized rabbits, we investigated whether the magnitude of respiratory changes in the aortic velocity time integral (VTI Ao), recorded by transthoracic echocardiography (TTE) during a stepwise blood withdrawal and restitution, could be used as a reliable indicator of volume depletion and responsiveness. At each step, left and right ventricular dimensions and the aortic diameter and VTI Ao were recorded to calculate stroke volume (SV) and cardiac output (CO). Respiratory changes of VTI Ao(maximal − minimal values divided by their respective means) were calculated. The amount of blood withdrawal correlated negatively with left and right ventricular diastolic diameters, VTI Ao, SV, and CO and correlated directly with respiratory changes of VTI Ao. Respiratory VTI Ao variations (but not other parameters) at the last blood withdrawal step was also correlated with changes in SV after blood restitution ( r = 0.83, P < 0.001). In conclusion, respiratory variations in VTI Ao using TTE appear to be a sensitive index of blood volume depletion and restitution. This dynamic parameter predicted fluid responsiveness more reliably than static markers of cardiac preload.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458 · cited 3×
“As surrogates of SV variation, respiratory variations of systemic arterial pressure (16, 11) or of aortic Doppler velocity (using transesophageal echocardiography) (8) have been reported to predict fluid responsiveness.”
BackgroundSelf-citationFeissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612 · cited 5×
“LV end-diastolic area has been shown to be a sensitive index of volume status (4, 5, 8, 14, 16, 18, 19).”
BackgroundMethodResultInfluentialSelf-citationSystolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced Hypotension
Tavernier, B., Makhotine, O., Lebuffe, G., Dupont, J., & Scherpereel, P. (1998) · Anesthesiology · doi:10.1097/00000542-199812000-00007 · Cited by 570 · cited 5×
“LV end-diastolic area has been shown to be a sensitive index of volume status (4, 5, 8, 14, 16, 18, 19).”
BackgroundResultInfluentialUsing heart-lung interactions to assess fluid responsiveness during mechanical ventilation.
Michard, F., & Teboul, J. (2000) · Critical Care · doi:10.1186/cc710 · Cited by 409 · cited 1×
“Moreover, in patients receiving mechanical ventilation, the magnitude of stroke volume (SV) variation over a respiratory cycle has been suggested to detect preload responsiveness (12).”
BackgroundSelf-citationDiebel, L. N., Wilson, R. F., Heins, J., Larky, H., Warsow, K. M., & Wilson, S. (1994) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199412000-00014 · Cited by 148 · cited 1×
“(7) also demonstrated a lower RV end-diastolic volume as assessed by a modified pulmonary artery catheter.”
MethodSwenson, J. D., Harkin, C. P., Pace, N. L., Astle, K. L., & Bailey, P. L. (1996) · Anesthesia & Analgesia · doi:10.1213/00000539-199612000-00003 · Cited by 95 · cited 1×
“(15) demonstrated a significant correlation when comparing LV end-diastolic area with changes in CO.”
BackgroundReich, D. L., Konstadt, S. N., NEJAT, M., Abrams, H. P., & Bucek, J. L. (1993) · Anesthesiology · doi:10.1097/00000542-199307000-00004 · Cited by 77
High Frame Rate Doppler Echocardiography in the Rat: an Evaluation of the Method
Bjørnerheim, R. (2001) · European Journal of Echocardiography · doi:10.1053/euje.2000.0050 · Cited by 26
Cited by
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Singh, Y., Tissot, C., Fraga, M. V., Yousef, N., Cortes, R. G., Lopez, J., Sanchez-de-Toledo, J., Brierley, J., Colunga, J. M., Raffaj, D., et al. (2020) · Critical Care · doi:10.1186/s13054-020-2787-9 · Cited by 659
Lamia, B., Ochagavia, A., Monnet, X., Chemla, D., Richard, C., & Teboul, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0646-7 · Cited by 393
Self-citationMuller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Diagnosis of central hypovolemia by using passive leg raising
Maizel, J., Airapetian, N., Lorne, E., Tribouilloy, C., Massy, Z., & Slama, M. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0642-y · Cited by 297
Self-citationEchocardiography in the critically ill: current and potential roles
Price, S., Nicol, E., Gibson, D. G., & Evans, T. W. (2006) · Intensive Care Medicine · doi:10.1007/s00134-005-2834-7 · Cited by 258
World Interactive Network Focused On Critical UltraSound ECHO-ICU Group, Price, S., Via, G., Sloth, E., Guarracino, F., Breitkreutz, R., Catena, E., & Talmor, D. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-49 · Cited by 255
Functional Hemodynamic Monitoring
Pinsky, M. R. (2015) · Critical Care Clinics · doi:10.1016/j.ccc.2014.08.005 · Cited by 168
“These other parameters derived from arterial pressure analysis include systolic pressure variation (SPV), aortic blood flow velocity recorded via esophageal Doppler ultrasound [59,60], pressure wave variation by pulse oximetry, aortic flow velocity time [61,62] and brachial flow variation time [63].”
MethodEchocardiographic Evaluation of Hemodynamics in Neonates and Children
Singh, Y. (2017) · Frontiers in Pediatrics · doi:10.3389/fped.2017.00201 · Cited by 116
Pees, C., Glagau, E., Hauser, J., & Michel-Behnke, I. (2013) · Pediatric Cardiology · doi:10.1007/s00246-012-0628-6 · Cited by 35
“Furthermore, studies in animal models have shown good correlation with changes in inotropy and afterload [24, 25].”
Result
Metadata
- Authors
- Slama, M., Masson, H., Teboul, J.-L., Arnout, M.-L., Susic, D., Frohlich, E., & Andrejak, M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2002-10-01
- Volume
- 283
- Issue
- 4
- Pages
- H1729-H1733
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2089634554
- Cited by
- 172
- References
- 9
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.