CoChat

Systematic evaluation of a novel model for cardiac ischemic preconditioning in mice

Eckle, Tobias, Grenz, Almut, Köhler, David, Redel, Andreas, Falk, Melanie, Rolauffs, Bernd, Osswald, Hartmut, Kehl, Franz, Eltzschig, Holger K. · 2006 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 125

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Cardioprotection by ischemic preconditioning (IP) remains an area of intense investigation. To further elucidate its molecular basis, the use of transgenic mice seems critical. Due to technical difficulty associated with performing cardiac IP in mice, we developed an in situ model for cardiac IP using a hanging-weight system for coronary artery occlusion. This technique has the major advantage of eliminating the necessity of intermittently occluding the coronary artery with a knotted suture. To systematically evaluate this model, we first demonstrated correlation of ischemia times (10–60 min) with infarct sizes [3.5 ± 1.3 to 42 ± 5.2% area at risk (AAR), Evan’s blue/triphenyltetrazolium chloride staining]. IP (4 × 5 min) and cold ischemia (27°C) reduced infarct size by 69 ± 6.7% and 84 ± 4.2%, respectively ( n = 6, P < 0.01). In contrast, lower numbers of IP cycles did not alter infarct size. However, infarct sizes were distinctively different in mice from different genetic backgrounds. In addition to infarct staining, we tested cardiac troponin I (cTnI) as marker of myocardial infarction in this model. In fact, plasma levels of cTnI were significantly lower in IP-treated mice and closely correlated with infarct sizes ( R 2 = 0.8). To demonstrate transcriptional consequences of cardiac IP, we isolated total RNA from the AAR and showed repression of the equilibrative nucleoside transporters 1–4 by IP in this model. Taken together, this study demonstrates highly reproducible infarct sizes and cardiac protection by IP, thus minimizing the variability associated with knot-based coronary occlusion models. Further studies on cardiac IP using transgenic mice may consider this technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.00472.2006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Current issues in mouse genome engineering

    Glaser, S., Anastassiadis, K., & Stewart, A. F. (2005) · Nature Genetics · doi:10.1038/ng1668 · Cited by 160 · cited 1×

    “Moreover, the use of “floxed” (9, 16) or chimeric (27) mice may yield additional insight into the contribution of individual tissues or cell lines (e.”
    Background

Show all 1 references

Cited by

Metadata

Authors
Eckle, T., Grenz, A., Köhler, D., Redel, A., Falk, M., Rolauffs, B., Osswald, H., Kehl, F., & Eltzschig, H. K.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2006-11
Volume
291
Issue
5
Pages
H2533-H2540
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2159138195
Cited by
125
References
1
FWCI
6.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.