Visualization and quantification of whole rat heart laminar structure using high-spatial resolution contrast-enhanced MRI
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
It has been shown by histology that cardiac myocytes are organized into laminae and this structure is important in function, both influencing the spread of electrical activation and enabling myocardial thickening in systole by laminar sliding. We have carried out high-spatial resolution three-dimensional MRI of the ventricular myolaminae of the entire volume of the isolated rat heart after contrast perfusion [dimeglumine gadopentate (Gd-DTPA)]. Four ex vivo rat hearts were perfused with Gd-DTPA and fixative and high-spatial resolution MRI was performed on a 9.4T MRI system. After MRI, cryosectioning followed by histology was performed. Images from MRI and histology were aligned, described, and quantitatively compared. In the three-dimensional MR images we directly show the presence of laminae and demonstrate that these are highly branching and are absent from much of the subepicardium. We visualized these MRI volumes to demonstrate laminar architecture and quantitatively demonstrated that the structural features observed are similar to those imaged in histology. We showed qualitatively and quantitatively that laminar architecture is similar in the four hearts. MRI can be used to image the laminar architecture of ex vivo hearts in three dimensions, and the images produced are qualitatively and quantitatively comparable with histology. We have demonstrated in the rat that: 1) laminar architecture is consistent between hearts; 2) myolaminae are absent from much of the subepicardium; and 3) although localized orthotropy is present throughout the myocardium, tracked myolaminae are branching structures and do not have a discrete identity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CircStat : A MATLAB Toolbox for Circular Statistics
Berens, P. (2009) · Journal of Statistical Software · doi:10.18637/jss.v031.i10 · Cited by 3,099 · cited 1×
“Statistical analysis and testing was carried out using the Circular Statistics Toolbox (4) for MatLab (Mathworks), custom written code, and the PAST statistics package (University of Oslo) (17).”
MethodCardiac Mechanics Revisited: The Relationship of Cardiac Architecture to Ventricular Function
Buckberg, G., Hoffman, J. I. E., Mahajan, A., Saleh, S., & Coghlan, C. (2008) · Circulation · doi:10.1161/circulationaha.107.754424 · Cited by 373 · cited 3×
“model (24); 2) the Functional Syncytial Mesh model (FSM) (2); and the 3) Helical Ventricular Myocardial Band (HVMB) model (6).”
BackgroundMethodLaminar fiber architecture and three-dimensional systolic mechanics in canine ventricular myocardium
Costa, K. D., Takayama, Y., McCulloch, A. D., & Covell, J. W. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.2.h595 · Cited by 313
Three-dimensional transmural organization of perimysial collagen in the heart
Pope, A. J., Sands, G. B., Smaill, B. H., & LeGrice, I. J. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00484.2008 · Cited by 205
Relating myocardial laminar architecture to shear strain and muscle fiber orientation
Arts, T., Costa, K. D., Covell, J. W., & McCulloch, A. D. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.5.h2222 · Cited by 172 · cited 2×
“This has become known as the Sheet Sliding Hypothesis, and it is supported by studies using cinematic radiography (10), force transducers (12), diffusion tensor-MRI (DT-MRI) (9), and computational simulation (3) (reviewed in detail in Ref.”
Method
Cited by
Image-Based Predictive Modeling of Heart Mechanics
Wang, V. Y., Nielsen, P. M. F., & Nash, M. P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040609 · Cited by 63
Stephenson, R. S., Agger, P., Lunkenheimer, P. P., Zhao, J., Smerup, M., Niederer, P., Anderson, R. H., & Jarvis, J. C. (2016) · Clinical Anatomy · doi:10.1002/ca.22661 · Cited by 33
Assessing Myocardial Architecture: The Challenges and Controversies
Agger, P., & Stephenson, R. S. (2020) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd7040047 · Cited by 11
“Hence, it makes sense physiologically that angles be assessed relative to the epicardial tangential plane (Figure 3), as this provides the most relevant information concerning cardiodynamics [17,25].”
BackgroundMethodInfluential
Metadata
- Authors
- Gilbert, S. H., Benoist, D., Benson, A. P., White, E., Tanner, S. F., Holden, A. V., Dobrzynski, H., Bernus, O., & Radjenovic, A.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2012-01
- Volume
- 302
- Issue
- 1
- Pages
- H287-H298
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2140417243
- Cited by
- 82
- References
- 5
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.