Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
At autopsy, 13 nonstenotic human left anterior descending coronary arteries [71.5 ± 7.3 (mean ± SD) yr old] were harvested, and related anamnesis was documented. Preconditioned prepared strips ( n = 78) of segments from the midregion of the left anterior descending coronary artery from the individual layers in axial and circumferential directions were subjected to cyclic quasi-static uniaxial tension tests, and ultimate tensile stresses and stretches were documented. The ratio of outer diameter to total wall thickness was 0.189 ± 0.014; ratios of adventitia, media, and intima thickness to total wall thickness were 0.4 ± 0.03, 0.36 ± 0.03, and 0.27 ± 0.02, respectively; axial in situ stretch of 1.044 ± 0.06 decreased with age. Stress-stretch responses for the individual tissues showed pronounced mechanical heterogeneity. The intima is the stiffest layer over the whole deformation domain, whereas the media in the longitudinal direction is the softest. All specimens exhibited small hysteresis and anisotropic and strong nonlinear behavior in both loading directions. The media and intima showed similar ultimate tensile stresses, which are on average three times smaller than ultimate tensile stresses in the adventitia (1,430 ± 604 kPa circumferential and 1,300 ± 692 kPa longitudinal). The ultimate tensile stretches are similar for all tissue layers. A recently proposed constitutive model was extended and used to represent the deformation behavior for each tissue type over the entire loading range. The study showed the need to model nonstenotic human coronary arteries with nonatherosclerotic intimal thickening as a composite structure composed of three solid mechanically relevant layers with different mechanical properties. The intima showed significant thickness, load-bearing capacity, and mechanical strength compared with the media and adventitia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
A new constitutive framework for arterial wall mechanics and a comparative study of material models
Holzapfel, G. A., Gasser, T. C., & Ogden, R. W. (2000) · Journal of Elasticity · doi:10.1023/a:1010835316564 · Cited by 3,071
Self-citationNonlinear Solid Mechanics: A Continuum Approach for Engineering
Holzapfel, G. A. (2000) · Cited by 2,700
Self-citationNonlinear Elastic Deformations
Ogden, R. W., & Sternberg, E. (1985) · Journal of Applied Mechanics · doi:10.1115/1.3169137 · Cited by 973
Kastrati, A., Mehilli, J., Dirschinger, J., Dotzer, F., Schühlen, H., Neumann, F.-J., Fleckenstein, M., Pfafferott, C., Seyfarth, M., & Schömig, A. (2001) · Circulation · doi:10.1161/01.cir.103.23.2816 · Cited by 938
THE REASON FOR THE SHAPE OF THE DISTENSIBILITY CURVES OF ARTERIES
Roach, M. R., & Burton, A. C. (1957) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o57-080 · Cited by 790
Biomechanics: Mechanical Properties of Living Tissues, 2nd ed.
Fung, Y. C., & Cowin, S. C. (1994) · Journal of Applied Mechanics · doi:10.1115/1.2901550 · Cited by 745
Pseudoelasticity of arteries and the choice of its mathematical expression
Fung, Y. C., Fronek, K., & Patitucci, P. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.5.h620 · Cited by 688
Predictive Factors of Restenosis After Coronary Stent Placement
Kastrati, A., Schömig, A., Elezi, S., Schühlen, H., Dirschinger, J., Hadamitzky, M., Wehinger, A., Hausleiter, J., Walter, H., & Neumann, F.-J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00334-3 · Cited by 685
Stary, H. C., Blankenhorn, D. H., Chandler, A. B., Glagov, S., Insull, W., Richardson, M., Rosenfeld, M. E., Schaffer, S. A., Schwartz, C. J., & Wagner, W. D. (1992) · Circulation · doi:10.1161/01.cir.85.1.391 · Cited by 627
Cited by
Hyperelastic modelling of arterial layers with distributed collagen fibre orientations
Gasser, T. C., Ogden, R. W., & Holzapfel, G. A. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0073 · Cited by 2,411
Self-citationKonig, G., McAllister, T. N., Dusserre, N., Garrido, S. A., Iyican, C., Marini, A., Fiorillo, A., Avila, H., Wystrychowski, W., Zagalski, K., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.11.011 · Cited by 582
Constitutive modelling of arteries
Holzapfel, G. A., & Ogden, R. W. (2010) · Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.2010.0058 · Cited by 528
“In Holzapfel et al. (2005a) the model was shown to fit the layer-specific mechanical properties of human coronary arteries very well, while in Holzapfel et al. (2005b) Proc.”
MethodResultSelf-citationMechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
Schriefl, A. J., Zeindlinger, G., Pierce, D. M., Regitnig, P., & Holzapfel, G. A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0727 · Cited by 353
Self-citationA polyconvex framework for soft biological tissues. Adjustment to experimental data
Balzani, D., Neff, P., Schröder, J., & Holzapfel, G. A. (2006) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2005.07.048 · Cited by 333
Self-citationHyperelastic Energy Densities for Soft Biological Tissues: A Review
Chagnon, G., Rebouah, M., & Favier, D. (2015) · Journal of Elasticity · doi:10.1007/s10659-014-9508-z · Cited by 292
Biomechanical properties and microstructure of human ventricular myocardium
Sommer, G., Schriefl, A. J., Andrä, M., Sacherer, M., Viertler, C., Wolinski, H., & Holzapfel, G. A. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.06.031 · Cited by 290
Self-citationModelling non-symmetric collagen fibre dispersion in arterial walls
Holzapfel, G. A., Niestrawska, J. A., Ogden, R. W., Reinisch, A. J., & Schriefl, A. J. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2015.0188 · Cited by 276
Self-citationRole of biomechanical forces in the natural history of coronary atherosclerosis
Brown, A. J., Teng, Z., Evans, P. C., Gillard, J. H., Samady, H., & Bennett, M. R. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2015.203 · Cited by 271
McClure, M. J., Sell, S. A., Simpson, D. G., Walpoth, B. H., & Bowlin, G. L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.029 · Cited by 267
Karimi, A., Navidbakhsh, M., Shojaei, A., & Faghihi, S. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.02.016 · Cited by 257
Pandolfi, A., & Holzapfel, G. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2982251 · Cited by 245
Self-citationLima, R., Wada, S., Tanaka, S., Takeda, M., Ishikawa, T., Tsubota, K.-I., Imai, Y., & Yamaguchi, T. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9121-z · Cited by 201
“The UTS and E of blood vessels have values from 0.4 to 1.4 MPa (Holzapfel et al. 2005) and ∼2.5 MPa (Steiger et al. 1989), respectively.”
BackgroundInfluentialStress-driven collagen fiber remodeling in arterial walls
Hariton, I., deBotton, G., Gasser, T. C., & Holzapfel, G. A. (2007) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0049-7 · Cited by 191
Self-citationSommer, G., Regitnig, P., Költringer, L., & Holzapfel, G. A. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00378.2009 · Cited by 183
Self-citationContinuum damage model for bioresorbable magnesium alloy devices — Application to coronary stents
Gastaldi, D., Sassi, V., Petrini, L., Vedani, M., Trasatti, S., & Migliavacca, F. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.11.003 · Cited by 173
Wang, D., Xu, Y., Li, Q., & Turng, L.-S. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb01849b · Cited by 171
Mortier, P., Holzapfel, G. A., De Beule, M., Van Loo, D., Taeymans, Y., Segers, P., Verdonck, P., & Verhegghe, B. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9836-5 · Cited by 165
Self-citationCilla, M., Pérez‐Rey, I., Martínez, M. A., Peña, E., & Martínez, J. (2018) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3121 · Cited by 38
Metadata
- Authors
- Holzapfel, G. A., Sommer, G., Gasser, C. T., & Regitnig, P.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2005-11
- Volume
- 289
- Issue
- 5
- Pages
- H2048-H2058
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2116463491
- Cited by
- 985
- References
- 32
- FWCI
- 14.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.