The DOI matches its Crossref record.
Quantitation of rhythmic diameter changes in arterial microcirculation
Abstract
The diameter of the arterial and arteriolar blood vessels was measured as a function of time in the hamster skin fold window preparation. When the animals recovered from the surgical implantation, the diameters of the arterial microvessels exhibited a continuous rhythmic activity throughout the preparation for a period of 2 wk while the chamber was intact. The amplitude of the diameter changes was directly proportional to the mean vessel size. The frequency of this phenomenon was determined by power spectrum analysis implemented with a Fourier transform method and was found to decrease from a maximum of 9-15 cycles/min in 8- to 15-micron A4 arterioles to 1-3 cycles/min in 70- to 100-micron A1 small arteries. A1 and A4 vessels had relatively well-defined characteristic fundamental frequencies, whereas A2 and A3 vessels showed a power spectrum that included the frequencies present in A1 and A4 vessels. The activity was not synchronized throughout the microvasculature, and frequencies and amplitudes of diameter variations changed at branching points. Anesthesia induced by the intravenous injections of pentobarbital and chloralose-urethan invariably stopped this activity throughout the preparation. The distribution of this time-dependent activity and the nature of the effect of the anesthetics suggests that this phenomenon is due to local pacemaker activity of groups of unitary smooth muscle cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Renal Autoregulation in Health and Disease
Carlström, M., Wilcox, C. S., & Arendshorst, W. J. (2015) · Physiological Reviews · doi:10.1152/physrev.00042.2012 · Cited by 485
Vasomotion: Mechanisms and Physiological Importance
Nilsson, H. (2003) · Molecular Interventions · doi:10.1124/mi.3.2.79 · Cited by 342
Vasomotion – what is currently thought?
Aalkjær, C., Boedtkjer, D., & Matchkov, V. (2011) · Acta Physiologica · doi:10.1111/j.1748-1716.2011.02320.x · Cited by 252
Vasomotion and flowmotion: physiological mechanisms and clinical evidence
Intaglietta, M. (1990) · Vascular Medicine Review · doi:10.1177/1358836x9000100202 · Cited by 99
Self-citationMaximum shortening velocity of lymphatic muscle approaches that of striated muscle
Zhang, R., Taucer, A. I., Gashev, A. A., Muthuchamy, M., Zawieja, D. C., & Davis, M. J. (2013) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00898.2012 · Cited by 26
Metadata
- Authors
- Colantuoni, A., Bertuglia, S., & Intaglietta, M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1984-04-01
- Volume
- 246
- Issue
- 4
- Pages
- H508-H517
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W71450445
- Cited by
- 243
- References
- 0
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitation of rhythmic diameter changes in arterial microcirculation. https://app.cochat.ai/papers/10.1152/ajpheart.1984.246.4.h508
- The paper
- Colantuoni, A., Bertuglia, S., & Intaglietta, M. (1984). Quantitation of rhythmic diameter changes in arterial microcirculation. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1984.246.4.h508
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.