The DOI matches its Crossref record.
Myogenic activity in isolated subepicardial and subendocardial coronary arterioles
Abstract
The goal of this study was to examine myogenic responses of isolated porcine subepicardial and subendocardial arterioles (80–100 micron in diameter) within physiological ranges of intraluminal pressure. Arterioles were located by perfusion with india ink-gelatin solution then dissected and cannulated with glass micropipettes. Intraluminal pressure was altered in 20-cmH2O steps over the range of 20–140 cmH2O. IN physiological salt solution (36–37 degrees C), the coronary arterioles developed spontaneous tone and exhibited myogenic responses. At the lower pressures (20–60 cmH2O), subendocardial arterioles responded passively (diameter decreased from a control diameter at 60 cmH2O), whereas subepicardial arterioles maintained their diameters. At higher pressures (100–140 cmH2O), both subepicardial and subendocardial arterioles demonstrated myogenic constriction, but subepicardial arterioles demonstrated greater myogenic constriction than subendocardial arterioles. This implies that myogenic autoregulation in subepicardial arterioles is better than that in the subendocardial arterioles at both low and high pressures. In the presence of nitroprusside (10(-4) M), all arterioles responded to pressure changes passively, and there were no differences between subepicardial and subendocardial vessels. The functional integrity of the endothelium was verified by relaxation to substance P (10(-7) M). This is the first in vitro study to demonstrate coronary myogenic activity and transmural differences in these arteriolar responses. Our data support the concept that myogenic mechanisms in 80 to 100-micron arterioles may actively contribute to autoregulation of coronary blood flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Signaling Mechanisms Underlying the Vascular Myogenic Response
Davis, M. J., & Hill, M. A. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.2.387 · Cited by 992
Self-citationIntravascular flow decreases erythrocyte consumption of nitric oxide
Liao, J. C., W. Hein, T., Vaughn, M. W., Huang, K.-T., & Kuo, L. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.15.8757 · Cited by 305
Self-citationRegulation of Cerebral Blood Flow
Peterson, E. C., Wang, Z., & Britz, G. (2011) · International Journal of Vascular Medicine · doi:10.1155/2011/823525 · Cited by 302
The myogenic response: established facts and attractive hypotheses
SCHUBERT, R., & MULVANY, M. J. (1999) · Clinical Science · doi:10.1042/cs0960313 · Cited by 273
Kuo, L., Davis, M. J., & Chilian, W. M. (1995) · Circulation · doi:10.1161/01.cir.92.3.518 · Cited by 253
Self-citation
Metadata
- Authors
- Kuo, L., Davis, M. J., & Chilian, W. M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1988-12-01
- Volume
- 255
- Issue
- 6
- Pages
- H1558-H1562
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2276737872
- Cited by
- 218
- References
- 0
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Myogenic activity in isolated subepicardial and subendocardial coronary arterioles. https://app.cochat.ai/papers/10.1152/ajpheart.1988.255.6.h1558
- The paper
- Kuo, L., Davis, M. J., & Chilian, W. M. (1988). Myogenic activity in isolated subepicardial and subendocardial coronary arterioles. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1988.255.6.h1558
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.