Endothelial albumin permeability is shear dependent, time dependent, and reversible
The DOI matches its Crossref record.
Abstract
Altered permeability of vascular endothelium to macromolecules may play a role in vascular disease as well as vascular homeostasis. Because the shear stress of flowing blood on the vascular wall is known to influence many endothelial cell properties, an in vitro system to measure transendothelial permeability (Pe) to fluorescein isothiocyanate conjugated bovine serum albumin under defined physiological levels of steady laminar shear stress was developed. Bovine aortic endothelial cells grown on polycarbonate filters pretreated with gelatin and fibronectin constituted the model system. Onset of 1 dyn/cm2 shear stress resulted in a Pe rise from 5.1 +/- 1.3 x 10(-6) cm/s to 21.9 +/- 4.6 X 10(-6) cm/s at 60 min (n = 6); while 10 dyn/cm2 shear stress increased Pe from 4.8 +/- 1.5 X 10(-6) cm/s to 50.2 +/- 6.8 X 10(-6) cm/s at 30 min and 49.6 +/- 8.9 X 10(-6) cm/s at 60 (n = 9). Pe returned to preshear values within 120 and 60 min after removal of 1 and 10 dyn/cm2 shear stress, respectively. The data show that endothelial cell Pe in vitro is acutely sensitive to shear stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of shear stress in the pathogenesis of atherosclerosis
Cunningham, K. S., & Gotlieb, A. I. (2005) · Laboratory Investigation · doi:10.1038/labinvest.3700215 · Cited by 1,151
Formation of perfused, functional microvascular tubes in vitro
Chrobak, K. M., Potter, D. R., & Tien, J. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.02.005 · Cited by 553
Spatial comparison between wall shear stress measures and porcine arterial endothelial permeability
Himburg, H. A., Grzybowski, D. M., Hazel, A. L., LaMack, J. A., Li, X.-M., & Friedman, M. H. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00897.2003 · Cited by 534
Biomechanical factors in atherosclerosis: mechanisms and clinical implications
Kwak, B. R., Bäck, M., Bochaton-Piallat, M.-L., Caligiuri, G., Daemen, M. J. A. P., Davies, P. F., Hoefer, I. E., Holvoet, P., Jo, H., Krams, R., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu353 · Cited by 502
Self-citationBerger, S. A., & Jou, L.-D. (2000) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.32.1.347 · Cited by 502
Regulation of vascular endothelial barrier function
Lum, H., & Malik, A. B. (1994) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.1994.267.3.l223 · Cited by 470
Small-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
The Mechanical Behavior of Vascular Grafts: A Review
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001) · Journal of Biomaterials Applications · doi:10.1106/na5t-j57a-jtdd-fd04 · Cited by 399
Shear stress and the endothelial transport barrier
Tarbell, J. M. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq146 · Cited by 365
Self-citationMass Transport in Arteries and the Localization of Atherosclerosis
Tarbell, J. M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121529 · Cited by 281
Self-citationMicrofluidic Models of Vascular Functions
Wong, K. H. K., Chan, J. M., Kamm, R. D., & Tien, J. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150052 · Cited by 247
“Subsequent addition of a flow chamber atop the filter system to impart physiological flow to the endothelium revealed the shear dependence of permeability (58).”
BackgroundBuchanan, C. F., Verbridge, S. S., Vlachos, P. P., & Rylander, M. N. (2014) · Cell Adhesion & Migration · doi:10.4161/19336918.2014.970001 · Cited by 205
“These findings are consistent with others showing shear stress-mediated endothelial morphological adaptations(22,38,49-52) and permeability.(14,17,19,21,23,53) The presence of tumor cells also increased Pd relative to endothelial mono-cultures, with a significantly greater Pd under high WSS conditions.”
BackgroundResultChronic shear induces caveolae formation and alters ERK and Akt responses in endothelial cells
Boyd, N. L., Park, H., Yi, H., Boo, Y. C., Sorescu, G. P., Sykes, M., & Jo, H. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00302.2003 · Cited by 187
“BAEC harvested from descending thoracic aortas were maintained (37°C, 5% CO2) in a growth medium [DMEM (1 g/l glucose, Mediatech) containing 20% FCS (Atlanta Biologicals) without antibiotics] (17).”
MethodSelf-citationProsi, M., Zunino, P., Perktold, K., & Quarteroni, A. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.04.024 · Cited by 187
Price, G. M., Wong, K. H. K., Truslow, J. G., Leung, A. D., Acharya, C., & Tien, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.041 · Cited by 184
Qiu, Y., & Tarbell, J. M. (2000) · Journal of Vascular Research · doi:10.1159/000025726 · Cited by 174
Self-citationComputational analysis of coupled blood-wall arterial LDL transport
Stangeby, D. K., & Ethier, C. R. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427041 · Cited by 154
Metadata
- Authors
- Jo, H., Dull, R. O., Hollis, T. M., & Tarbell, J. M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1991-06-01
- Volume
- 260
- Issue
- 6
- Pages
- H1992-H1996
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2339933226
- Cited by
- 168
- References
- 0
- FWCI
- 4.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.