The DOI matches its Crossref record.
Myogenic response gradient in an arteriolar network
Abstract
Experiments were conducted to test the hypothesis that a longitudinal gradient in myogenic responsiveness exists within an arteriolar network. Single arterioles were dissected from the hamster cheek pouch, cannulated with micropipettes, and transferred to an inverted microscope for in vitro study. Pressure-diameter relationships of five branching orders of arterial vessels were measured in the presence of spontaneous vascular tone and after elimination of tone with a Ca(2+)-free solution containing nitroprusside. At luminal pressures matching those found in vivo, the diameters of the vessels with spontaneous tone were as follows: small arteries, 81 microns; first-order arterioles, 52 microns; second-order arterioles, 32 microns; third-order arterioles, 24 microns; and fourth-order arterioles, 11 microns. All branching orders of vessels exhibited true myogenic responses as indicated by negative slopes of their pressure-diameter relationships. Each vascular branching order exhibited its maximum myogenic responsiveness at a pressure near or just slightly higher than its normal pressure as measured in vivo. Relative myogenic responsiveness increased with decreasing vessel size down to the level of the second- and third-order arterioles, whereas fourth-order arterioles were substantially less responsive than third-order arterioles. A compilation of data from numerous in vivo and in vitro studies suggests that the same myogenic response pattern may be found in other vascular beds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Signaling Mechanisms Underlying the Vascular Myogenic Response
Davis, M. J., & Hill, M. A. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.2.387 · Cited by 992
Self-citationMitchell, G. F. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90549.2008 · Cited by 764
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Self-citationThe myogenic response: established facts and attractive hypotheses
SCHUBERT, R., & MULVANY, M. J. (1999) · Clinical Science · doi:10.1042/cs0960313 · Cited by 273
Local Regulation of Microvascular Perfusion
Davis, M. J., Hill, M. A., & Kuo, L. (2008) · Microcirculation · doi:10.1016/b978-0-12-374530-9.00006-1 · Cited by 78
Self-citation
Metadata
- Authors
- Davis, M. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1993-06-01
- Volume
- 264
- Issue
- 6
- Pages
- H2168-H2179
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2289172208
- Cited by
- 161
- References
- 0
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Myogenic response gradient in an arteriolar network. https://app.cochat.ai/papers/10.1152/ajpheart.1993.264.6.h2168
- The paper
- Davis, M. J. (1993). Myogenic response gradient in an arteriolar network. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1993.264.6.h2168
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.