Capillaries and arterioles are electrically coupled in hamster cheek pouch
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this report we demonstrate electrical communication in the microcirculation between arterioles and capillary networks in situ. Microvessel networks in the hamster cheek pouch, which included capillaries and their feeding arterioles, were labeled with the voltage-sensitive dye di-8-ANEPPS by intraluminal perfusion through a micropipette. Pulses of 140 mM potassium solution were applied by pressure ejection from micropipettes positioned on arterioles several hundred micrometers upstream from capillaries. Potassium caused membrane potential changes of 3–11 mV in capillary segments up to 1,200 μm distal to the stimulation site, with time delays of <1 s. Capillary membrane potential changes were biphasic, with initial depolarizations followed by hyperpolarizations. The size of the response decreased exponentially with the distance between the arteriole and capillary, with a 1/e distance of 590 μm. The time to peak depolarization of both arteriolar and capillary segments was similar. The time to peak response was significantly faster than that for responses from direct stimulation of capillaries. Capillary responses were also obtained when blood flow was either blocked or directed toward sites of stimulation. Acetylcholine (10−4 M) and phenylephrine (10−5 M) applied to the arterioles by iontophoresis produced monophasic hyperpolarizing and depolarizing responses, respectively, in capillaries with <1-s delay between stimulus and onset of the membrane potential change. These results provide evidence in situ of a pathway for electrical communication between arteriolar and capillary levels of the microcirculation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Little, T. L., Beyer, E. C., & Duling, B. R. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.268.2.h729 · Cited by 292
Self-citation
Cited by
Regulation of Blood Flow in the Microcirculation
SEGAL, S. S. (2005) · Microcirculation · doi:10.1080/10739680590895028 · Cited by 540
Capillary K+-sensing initiates retrograde hyperpolarization to increase local cerebral blood flow
Longden, T. A., Dabertrand, F., Koide, M., Gonzales, A. L., Tykocki, N. R., Brayden, J. E., Hill-Eubanks, D., & Nelson, M. T. (2017) · Nature Neuroscience · doi:10.1038/nn.4533 · Cited by 522
Monitoring the microcirculation in the critically ill patient: current methods and future approaches
De Backer, D., Ospina-Tascon, G., Salgado, D., Favory, R., Creteur, J., & Vincent, J.-L. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-2005-3 · Cited by 426
Pathophysiology of microcirculatory dysfunction and the pathogenesis of septic shock
De Backer, D., Orbegozo Cortes, D., Donadello, K., & Vincent, J.-L. (2014) · Virulence · doi:10.4161/viru.26482 · Cited by 393
Gap Junctions in the Control of Vascular Function
Figueroa, X. F., & Duling, B. R. (2009) · Antioxidants & Redox Signaling · doi:10.1089/ars.2008.2117 · Cited by 294
Self-citationRegulation of blood flow in the microcirculation: role of conducted vasodilation
Bagher, P., & Segal, S. S. (2011) · Acta Physiologica · doi:10.1111/j.1748-1716.2010.02244.x · Cited by 248
“Using a voltage-sensitive dye (di-8-ANEPPS), capillaries in the hamster cheek pouch depolarized in response to KCl or phenylephrine and hyperpolarized in response to ACh when these agonists were ejected from micropipettes (Beach et al. 1998, McGahren et al. 1998).”
BackgroundLaughlin, M. H., Davis, M. J., Secher, N. H., van Lieshout, J. J., Arce‐Esquivel, A. A., Simmons, G. H., Bender, S. B., Padilla, J., Bache, R. J., Merkus, D., et al. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100048 · Cited by 241
Coupling of muscle metabolism and muscle blood flow in capillary units during contraction
Murrant, C. L., & Sarelius, I. H. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00706.x · Cited by 101
Local Regulation of Microvascular Perfusion
Davis, M. J., Hill, M. A., & Kuo, L. (2008) · Microcirculation · doi:10.1016/b978-0-12-374530-9.00006-1 · Cited by 78
Capillary endothelial cells as coordinators of skeletal muscle blood flow during active hyperemia
Murrant, C. L., Lamb, I. R., & Novielli, N. M. (2017) · Microcirculation · doi:10.1111/micc.12348 · Cited by 37
“At the arteriolar level, acetylcholine (ACh) has been used extensively to explore the nature of conducted vasodilatory responses (for example [6,7,24,28,29,81,88,90,106]).”
Background
Metadata
- Authors
- Beach, J. M., McGahren, E. D., & Duling, B. R.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1998-10-01
- Volume
- 275
- Issue
- 4
- Pages
- H1489-H1496
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2101515703
- Cited by
- 82
- References
- 1
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.