Developmental changes of cardiac function and mass assessed with MRI in neonatal, juvenile, and adult mice
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Cardiovascular transgenic mouse models with an early phenotype or even premature death require noninvasive imaging methods that allow for accurate visualization of cardiac morphology and function. Thus the purpose of our study was to assess the feasibility of magnetic resonance imaging (MRI) to characterize cardiac function and mass in newborn, juvenile, and adult mice. Forty-five C57bl/6 mice from seven age groups (3 days to 4 mo after birth) were studied by MRI under isoflurane anesthesia. Electrocardiogram-gated cine MRI was performed with an in-plane resolution of (78–117 μm)2. Temporal resolution per cine frame was 8.6 ms. MRI revealed cardiac anatomy in mice from all age groups with high temporal and spatial resolution. There was close correlation between MRI- and autopsy-determined left ventricular (LV) mass ( r = 0.95, SE of estimate = 9.5 mg). The increase of LV mass (range 9.6–101.3 mg), cardiac output (range 1.1–14.3 ml/min), and stroke volume (range 3.2–40.2 μl) with age could be quantified by MRI measurements. Ejection fraction and cardiac index did not change with aging. However, LV mass index decreased with increasing age ( P < 0.01). High-resolution MRI allows for accurate in vivo assessment of cardiac function in neonatal, juvenile, and adult mice. This method should be useful when applied in transgenic mouse models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
Self-citationAn efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
Hayes, C. E., Edelstein, W. A., Schenck, J. F., Mueller, O. M., & Eash, M. G. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90257-4 · Cited by 912 · cited 1×
“For NMR signal transmission and reception, laboratory-built birdcage probe heads (5) with varying inner diameters were used.”
MethodLorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
A Mouse Model of Familial Hypertrophic Cardiomyopathy
Geisterfer-Lowrance, A. A. T., Christe, M., Conner, D. A., Ingwall, J. S., Schoen, F. J., Seidman, C. E., & Seidman, J. G. (1996) · Science · doi:10.1126/science.272.5262.731 · Cited by 556 · cited 1×
“Because the consequences of gene alterations may become manifest at an early age (1, 6), noninvasive, sequential characterization of the cardiac phenotype during development is crucial.”
Measurement of right and left ventricular volumes in healthy individuals with cine MR imaging.
Sechtem, U., Pflugfelder, P. W., Gould, R. G., Cassidy, M. M., & Higgins, C. B. (1987) · Radiology · doi:10.1148/radiology.163.3.3575717 · Cited by 407 · cited 1×
“Magnetic resonance imaging (MRI) has proven to be highly accurate and reproducible in the assessment of cardiac morphology and function in both animals (14) and humans (13).”
BackgroundHoit, B. D., Khoury, S. F., Kranias, E. G., Ball, N., & Walsh, R. A. (1995) · Circulation Research · doi:10.1161/01.res.77.3.632 · Cited by 241 · cited 1×
“Measurement of cardiac function in adult mice has been successfully demonstrated by M-mode echocardiography (7, 10).”
MethodHein, L., Stevens, M. E., Barsh, G. S., Pratt, R. E., Kobilka, B. K., & Dzau, V. J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.12.6391 · Cited by 212 · cited 1×
“Because the consequences of gene alterations may become manifest at an early age (1, 6), noninvasive, sequential characterization of the cardiac phenotype during development is crucial.”
BackgroundSmith, H. L. (1928) · American Heart Journal · doi:10.1016/s0002-8703(29)90099-5 · Cited by 191 · cited 1×
“Consistent with developmental changes in humans (2, 17), we found a significant decrease in LV mass index and no change in LV EF with physiological growth.”
Ruff, J., Wiesmann, F., Hiller, K., Voll, S., von Kienlin, M., Bauer, W. R., Rommel, E., Neubauer, S., & Haase, A. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400106 · Cited by 181 · cited 1×
“Whereas visualization of the murine heart by conventional (slow) MRI techniques has been reported (15, 16), we were recently able to demonstrate the application of a faster MRI method for assessment of left ventricular (LV) volumes and mass in adult mice (12), in which data acquisition with high temporal resolution an…”
MethodSelf-citationShapiro, E. P., Rogers, W. J., Beyar, R., Soulen, R. L., Zerhouni, E. A., Lima, J. A., & Weiss, J. L. (1989) · Circulation · doi:10.1161/01.cir.79.3.706 · Cited by 163 · cited 1×
“Magnetic resonance imaging (MRI) has proven to be highly accurate and reproducible in the assessment of cardiac morphology and function in both animals (14) and humans (13).”
Background
Cited by
Vascular Extracellular Matrix and Arterial Mechanics
Wagenseil, J. E., & Mecham, R. P. (2009) · Physiological Reviews · doi:10.1152/physrev.00041.2008 · Cited by 1,059
Guidelines for measuring cardiac physiology in mice
Lindsey, M. L., Kassiri, Z., Virag, J. A. I., de Castro Brás, L. E., & Scherrer-Crosbie, M. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00339.2017 · Cited by 349
In vivo small-animal imaging using micro-CT and digital subtraction angiography
Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/19/r01 · Cited by 264
In Vivo mouse imaging and spectroscopy in drug discovery
Beckmann, N., Kneuer, R., Gremlich, H., Karmouty‐Quintana, H., Blé, F., & Müller, M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1153 · Cited by 118
Liu, Y., Conboy, M. J., Mehdipour, M., Liu, Y., Tran, T. P., Blotnick, A., Rajan, P., Santos, T. C., & Conboy, I. M. (2017) · Nature Communications · doi:10.1038/s41467-017-00698-y · Cited by 59
Metadata
- Authors
- Wiesmann, F., Ruff, J., Hiller, K.-H., Rommel, E., Haase, A., & Neubauer, S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2000-02-01
- Volume
- 278
- Issue
- 2
- Pages
- H652-H657
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2418262242
- Cited by
- 165
- References
- 14
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.