The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Larger late sodium conductance in M cells contributes to electrical heterogeneity in canine ventricle
Abstract
Action potentials and whole cell sodium current were recorded in canine epicardial, midmyocardial, and endocardial myocytes in normal sodium at 37°C. Tetrodotoxin (TTX) reduced the action potential duration of midmyocardial cells to a greater degree than either epicardial or endocardial cells. Whole cell recordings in potassium-free and very-low-chloride solutions revealed a slowly decaying current that was completely inhibited by 5 μM TTX or replacement of external and internal sodium with the impermeant cation N-methyl-d-glucamine. Late sodium current density at 0 mV was 47% greater in midmyocardial cells and averaged −0.532 ± 0.058 pA/pF in endocardial, −0.463 ± 0.068 pA/pF in epicardial, and −0.785 ± 0.070 pA/pF in midmyocardial cells. Neither the frequency dependence of late sodium current nor its recovery from inactivation exhibited transmural differences. After a 4.5-s pulse to −30 mV, late sodium current recovered with a single time constant of 140 ms. We conclude that a larger late sodium conductance in midmyocardial cells will favor longer action potentials in these cells. More importantly, drugs that slow inactivation of sodium channels will produce a nonuniform response across the ventricular wall that is proarrhythmic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luo, C. H., & Rudy, Y. (1994) · Circulation Research · doi:10.1161/01.res.74.6.1071 · Cited by 1,589
Muscarinic activation of ionic currents measured by a new whole-cell recording method.
Horn, R., & Marty, A. (1988) · The Journal of general physiology · doi:10.1085/jgp.92.2.145 · Cited by 1,338
Yan, G.-X., & Antzelevitch, C. (1999) · Circulation · doi:10.1161/01.cir.100.15.1660 · Cited by 1,126
Self-citationYan, G.-X., & Antzelevitch, C. (1998) · Circulation · doi:10.1161/01.cir.98.18.1928 · Cited by 988
Self-citationAntzelevitch, C., Sicouri, S., Litovsky, S. H., Lukas, A., Krishnan, S. C., Di Diego, J. M., Gintant, G. A., & Liu, D. W. (1991) · Circulation Research · doi:10.1161/01.res.69.6.1427 · Cited by 734
Self-citationThe M Cell: Its Contribution to the ECG and to Normal and Abnormal Electrical Function of the Heart
ANTZELEVITCH, C., SHIMIZU, W., YAN, G., SICOURI, S., WEISSENBURGER, J., NESTERENKO, V. V., BURASHNIKOV, A., DI DIEGO, J., SAFFITZ, J., & THOMAS, G. P. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00287.x · Cited by 611
Self-citationLiu, D.-W., & Antzelevitch, C. (1995) · Circulation Research · doi:10.1161/01.res.76.3.351 · Cited by 609
Self-citationShimizu, W., & Antzelevitch, C. (1997) · Circulation · doi:10.1161/01.cir.96.6.2038 · Cited by 524
Self-citationShimizu, W., & Antzelevitch, C. (1998) · Circulation · doi:10.1161/01.cir.98.21.2314 · Cited by 499
Self-citationLiu, D. W., Gintant, G. A., & Antzelevitch, C. (1993) · Circulation Research · doi:10.1161/01.res.72.3.671 · Cited by 459
Self-citation
Cited by
A model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416
Electrophysiological Effects of Ranolazine, a Novel Antianginal Agent With Antiarrhythmic Properties
Antzelevitch, C., Belardinelli, L., Zygmunt, A. C., Burashnikov, A., Di Diego, J. M., Fish, J. M., Cordeiro, J. M., & Thomas, G. (2004) · Circulation · doi:10.1161/01.cir.0000139333.83620.5d · Cited by 675
Self-citationOverview of Basic Mechanisms of Cardiac Arrhythmia
Antzelevitch, C., & Burashnikov, A. (2011) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2010.10.012 · Cited by 464
Self-citationKannankeril, P., Roden, D. M., & Darbar, D. (2010) · Pharmacological Reviews · doi:10.1124/pr.110.003723 · Cited by 440
The genetic basis of long QT and short QT syndromes: A mutation update
Hedley, P. L., Jørgensen, P., Schlamowitz, S., Wangari, R., Moolman-Smook, J., Brink, P. A., Kanters, J. K., Corfield, V. A., & Christiansen, M. (2009) · Human Mutation · doi:10.1002/humu.21106 · Cited by 429
Metadata
- Authors
- Zygmunt, A. C., Eddlestone, G. T., Thomas, G. P., Nesterenko, V. V., & Antzelevitch, C.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2001-08-01
- Volume
- 281
- Issue
- 2
- Pages
- H689-H697
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2298979802
- Cited by
- 254
- References
- 23
- FWCI
- 10.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Larger late sodium conductance in M cells contributes to electrical heterogeneity in canine ventricle. https://app.cochat.ai/papers/10.1152/ajpheart.2001.281.2.h689
- The paper
- Zygmunt, A. C., Eddlestone, G. T., Thomas, G. P., Nesterenko, V. V., & Antzelevitch, C. (2001). Larger late sodium conductance in M cells contributes to electrical heterogeneity in canine ventricle. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.2001.281.2.h689
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.