CoChat

Hydrogen sulfide as an oxygen sensor in trout gill chemoreceptors

Olson, Kenneth R., Healy, Michael J., Qin, Zhaohong, Skovgaard, Nini, Vulesevic, Branka, Duff, Douglas W., Whitfield, Nathan L., Yang, Guangdong, Wang, Rui, Perry, Steve F. · 2008 · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Cited by 131

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

O 2 chemoreceptors elicit cardiorespiratory reflexes in all vertebrates, but consensus on O 2-sensing signal transduction mechanism(s) is lacking. We recently proposed that hydrogen sulfide (H 2 S) metabolism is involved in O 2 sensing in vascular smooth muscle. Here, we examined the possibility that H 2 S is an O 2 sensor in trout chemoreceptors where the first pair of gills is a primary site of aquatic O 2 sensing and the homolog of the mammalian carotid body. Intrabuccal injection of H 2 S in unanesthetized trout produced a dose-dependent bradycardia and increased ventilatory frequency and amplitude similar to the hypoxic response. Removal of the first, but not second, pair of gills significantly inhibited H 2 S-mediated bradycardia, consistent with the loss of aquatic chemoreceptors. mRNA for H 2 S-synthesizing enzymes, cystathionine β-synthase and cystathionine γ-lyase, was present in branchial tissue. Homogenized gills produced H 2 S enzymatically, and H 2 S production was inhibited by O 2, whereas mitochondrial H 2 S consumption was O 2 dependent. Ambient hypoxia did not affect plasma H 2 S in unanesthetized trout, but produced a Po 2-dependent increase in a sulfide moiety suggestive of increased H 2 S production. In isolated zebrafish neuroepithelial cells, the putative chemoreceptive cells of fish, both hypoxia and H 2 S, produced a similar ∼10-mV depolarization. These studies are consistent with H 2 S involvement in O 2 sensing/signal transduction pathway(s) in chemoreceptive cells, as previously demonstrated in vascular smooth muscle. This novel mechanism, whereby H 2 S concentration ([H 2 S]) is governed by the balance between constitutive production and oxidation, tightly couples tissue [H 2 S] to Po 2 and may provide an exquisitely sensitive, yet simple, O 2 sensor in a variety of tissues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpregu.00807.2007

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 131

Metadata

Authors
Olson, K. R., Healy, M. J., Qin, Z., Skovgaard, N., Vulesevic, B., Duff, D. W., Whitfield, N. L., Yang, G., Wang, R., & Perry, S. F.
Venue
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Published
2008-08
Volume
295
Issue
2
Pages
R669-R680
ISSN
  • 0363-6119 (ISSN-L)
  • 1522-1490
OpenAlex
W2101952797
Cited by
131
References
2
FWCI
4.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.