Properties of the Na+-H+ exchanger in renal microvillus membrane vesicles
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331 · cited 1×
“Dialysis tubing was obtained from Fisher Scientific (8-6673), boiled in 2 mM Na2-EDTA, and extensively rinsed with deionized water.”
MethodMurer, H., Hopfer, U., & Kinne, R. (1976) · Biochemical Journal · doi:10.1042/bj1540597 · Cited by 674
A rapid method for the preparation of microvilli from rabbit kidney
Booth, A. G., & Kenny, A. J. (1974) · Biochemical Journal · doi:10.1042/bj1420575 · Cited by 607 · cited 2×
“Dialysis tubing was obtained from Fisher Scientific (8-6673), boiled in 2 mM Na2-EDTA, and extensively rinsed with deionized water.”
MethodIntracellular pH and Activation of Sea Urchin Eggs after Fertilisation
Johnson, J. D., Epel, D., & Paul, M. (1976) · Nature · doi:10.1038/262661a0 · Cited by 556
Binding of Diffusible Molecules by Macromolecules: Rapid Measurement by Rate of Dialysis
Colowick, S. P., & Womack, F. C. (1969) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)94419-4 · Cited by 515 · cited 2×
“Dialysis tubing was obtained from Fisher Scientific (8-6673), boiled in 2 mM Na2-EDTA, and extensively rinsed with deionized water.”
MethodAn investigation of the ionic mechanism of intracellular pH regulation in mouse soleus muscle fibres
Aickin, C. C., & Thomas, R. C. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp012095 · Cited by 402
Aronson, P. S. (1978) · The Journal of Membrane Biology · doi:10.1007/bf01870395 · Cited by 162
Self-citation
Cited by
(1989) · PubMed · Cited by 1,639
Amiloride: a molecular probe of sodium transport in tissues and cells
Benos, D. J. (1982) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1982.242.3.c131 · Cited by 839
Voltage-Gated Proton Channels and Other Proton Transfer Pathways
Decoursey, T. E. (2003) · Physiological Reviews · doi:10.1152/physrev.00028.2002 · Cited by 737
Mechanisms of regulation of the Na+/H+ exchanger
Grinstein, S., & Rothstein, A. (1986) · The Journal of Membrane Biology · doi:10.1007/bf01869680 · Cited by 679
Kinetic Properties of the Plasma Membrane Na+ -H+ Exchanger
Aronson, P. S. (1985) · Annual Review of Physiology · doi:10.1146/annurev.ph.47.030185.002553 · Cited by 679
Self-citation
Metadata
- Authors
- Kinsella, J. L., & Aronson, P. S.
- Venue
- American Journal of Physiology-Renal Physiology
- Publisher
- American Physiological Society
- Published
- 1980-06-01
- Volume
- 238
- Issue
- 6
- Pages
- F461-F469
- ISSN
- 1522-1466 (ISSN-L)
- 1931-857X
- OpenAlex
- W2409588091
- Cited by
- 251
- References
- 7
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.