Optimized suspension culture: the rotating-wall vessel
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Suspension culture remains a popular modality, which manipulates mechanical culture conditions to maintain the specialized features of cultured cells. The rotating-wall vessel is a suspension culture vessel optimized to produce laminar flow and minimize the mechanical stresses on cell aggregates in culture. This review summarizes the engineering principles, which allow optimal suspension culture conditions to be established, and the boundary conditions, which limit this process. We suggest that to minimize mechanical damage and optimize differentiation of cultured cells, suspension culture should be performed in a solid-body rotation Couette-flow, zero-headspace culture vessel such as the rotating-wall vessel. This provides fluid dynamic operating principles characterized by 1) solid body rotation about a horizontal axis, characterized by colocalization of cells and aggregates of different sedimentation rates, optimally reduced fluid shear and turbulence, and three-dimensional spatial freedom; and 2) oxygenation by diffusion. Optimization of suspension culture is achieved by applying three tradeoffs. First, terminal velocity should be minimized by choosing microcarrier beads and culture media as close in density as possible. Next, rotation in the rotating-wall vessel induces both Coriolis and centrifugal forces, directly dependent on terminal velocity and minimized as terminal velocity is minimized. Last, mass transport of nutrients to a cell in suspension culture depends on both terminal velocity and diffusion of nutrients. In the transduction of mechanical culture conditions into cellular effects, several lines of evidence support a role for multiple molecular mechanisms. These include effects of shear stress, changes in cell cycle and cell death pathways, and upstream regulation of secondary messengers such as protein kinase C. The discipline of suspension culture needs a systematic analysis of the relationship between mechanical culture conditions and biological effects, emphasizing cellular processes important for the industrial production of biological pharmaceuticals and devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cluster analysis and display of genome-wide expression patterns
Eisen, M. B., Spellman, P. T., Brown, P. O., & Botstein, D. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.25.14863 · Cited by 16,184
Feder, M. E., & Hofmann, G. E. (1999) · Annual Review of Physiology · doi:10.1146/annurev.physiol.61.1.243 · Cited by 4,287
Exploring the new world of the genome with DNA microarrays
Brown, P. O., & Botstein, D. (1999) · Nature Genetics · doi:10.1038/4462 · Cited by 2,414
Fundamentals of momentum, heat, and mass transfer
Welty, J. R. (1969) · Cited by 1,541
Flow regimes in a circular Couette system with independently rotating cylinders
Andereck, C. D., Liu, S. S., & Swinney, H. L. (1986) · Journal of Fluid Mechanics · doi:10.1017/s0022112086002513 · Cited by 1,202
Vunjak‐Novakovic, G., Martin, I., Obradovic, B., Treppo, S., Grodzinsky, A. J., Langer, R., & Freed, L. E. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170119 · Cited by 743
Insulin independence in a type 1 diabetic patient after encapsulated islet transplantation
Soon-Shiong, P., Heintz, R. E., Merideth, N., Yao, Q. X., Yao, Z., Zheng, T., Murphy, M., Moloney, M. K., Schmehl, M., Harris, M., et al. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90067-1 · Cited by 659
Drug target validation and identification of secondary drug target effects using DNA microarrays
Marton, M. J., DeRisi, J. L., Bennett, H. A., Iyer, V. R., Meyer, M. R., Roberts, C. J., Stoughton, R., Burchard, J., Slade, D., Dai, H., et al. (1998) · Nature Medicine · doi:10.1038/3282 · Cited by 643
Alginate polycation microcapsules
Thu, B., Bruheim, P., Espevik, T., Smidsrød, O., Soon-Shiong, P., & Skjåk-Bræk, G. (1996) · Biomaterials · doi:10.1016/0142-9612(96)84680-1 · Cited by 507
Tissue engineering of cartilage in space
Freed, L. E., Langer, R., Martin, I., Pellis, N. R., & Vunjak-Novakovic, G. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.25.13885 · Cited by 435
Cited by
The use of 3-d cultures for high-throughput screening: the multicellular spheroid model.
Kunz-Schughart, L. A., Freyer, J. P., Hofstaedter, F., & Ebner, R. (2004) · SLAS DISCOVERY · doi:10.1177/1087057104265040 · Cited by 797
Three-dimensional tissue culture models in cancer biology
Kim, J. B. (2005) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2005.05.002 · Cited by 613
Wilson, J. W., Ott, C. M., zu Bentrup, K. H., Ramamurthy, R., Quick, L., Porwollik, S., Cheng, P., McClelland, M., Tsaprailis, G., Radabaugh, T., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707155104 · Cited by 516
Self-citationHerranz, R., Anken, R., Boonstra, J., Braun, M., Christianen, P. C. M., de Geest, M., Hauslage, J., Hilbig, R., Hill, R. J. A., Lebert, M., et al. (2013) · Astrobiology · doi:10.1089/ast.2012.0876 · Cited by 482
Three-dimensional in vitro tumor models for cancer research and drug evaluation
Xu, X., Farach-Carson, M. C., & Jia, X. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.07.009 · Cited by 461
Microbial Responses to Microgravity and Other Low-Shear Environments
Nickerson, C. A., Ott, C. M., Wilson, J. W., Ramamurthy, R., & Pierson, D. L. (2004) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.68.2.345-361.2004 · Cited by 393
Hickman, J. A., Graeser, R., de Hoogt, R., Vidic, S., Brito, C., Gutekunst, M., van der Kuip, H., & IMI PREDECT consortium (2014) · Biotechnology Journal · doi:10.1002/biot.201300492 · Cited by 380
Chitosan scaffolds: Interconnective pore size and cartilage engineering
GRIFFON, D., SEDIGHI, M., SCHAEFFER, D., EURELL, J., & JOHNSON, A. (2006) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.12.007 · Cited by 351
Chang, T. T., & Hughes-Fulford, M. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0434 · Cited by 311
The Wnt Inhibitor Sclerostin Is Up-regulated by Mechanical Unloading in Osteocytes in Vitro
Spatz, J. M., Wein, M. N., Gooi, J. H., Qu, Y., Garr, J. L., Liu, S., Barry, K. J., Uda, Y., Lai, F., Dedic, C., et al. (2015) · Journal of Biological Chemistry · doi:10.1074/jbc.m114.628313 · Cited by 290
Modelling tissues in 3D: the next future of pharmaco-toxicology and food research?
Mazzoleni, G., Di Lorenzo, D., & Steimberg, N. (2009) · Genes & Nutrition · doi:10.1007/s12263-008-0107-0 · Cited by 253
Gerecht‐Nir, S., Cohen, S., & Itskovitz‐Eldor, J. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20045 · Cited by 232
“Previous studies have shown that the conventional stirrer vessels may have the disadvantage of generating shear forces and, although manageable, these forces still damage the cells (Chisti, 2001; Hammond and Hammond, 2001).”
BackgroundStem cells in bone tissue engineering
Seong, J. M., Kim, B.-C., Park, J.-H., Kwon, I. K., Mantalaris, A., & Hwang, Y.-S. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/6/062001 · Cited by 225
“…systems have also been recently applied to fabricate in vitro 3D bone-like tissue constructs by enhancing the mass transport of nutrients and by providing a suspension culture environment (Hwang et al 2009a, Zhang et al 2009a, Hammond and Hammond 2001), which facilitates 3D tissue formation.”
MethodMouse Models of Escherichia coli O157:H7 Infection and Shiga Toxin Injection
Mohawk, K. L., & O′Brien, A. D. (2011) · BioMed Research International · doi:10.1155/2011/258185 · Cited by 167
“coli O157:H7 adherence and subsequent host cell damage is the organoid system in which cells grown on a scaffold under microgravity conditions form pieces of tissue-like material [60–62].”
BackgroundSaxena, R., Pan, G., Dohm, E. D., & McDonald, J. M. (2011) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-010-0201-4 · Cited by 80
Simulated microgravity‐induced epigenetic changes in human lymphocytes
Singh, K. P., Kumari, R., & DuMond, J. W. (2010) · Journal of Cellular Biochemistry · doi:10.1002/jcb.22674 · Cited by 64
Hendrickx, L., Mastroleo, F., Baatout, S., Mergeay, M., Paillé, C., & Wattiez, R. (2005) · SAE Technical Paper Series · doi:10.4271/2005-01-3073 · Cited by 1
Metadata
- Authors
- Hammond, T. G., & Hammond, J. M.
- Venue
- American Journal of Physiology-Renal Physiology
- Publisher
- American Physiological Society
- Published
- 2001-07-01
- Volume
- 281
- Issue
- 1
- Pages
- F12-F25
- ISSN
- 1522-1466 (ISSN-L)
- 1931-857X
- OpenAlex
- W1929308123
- Cited by
- 437
- References
- 52
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.